Technical Paper
Test Results on Reuse of Reclaimed Shower Water - A Summary
1989-07-01
891443
A microgravity whole body shower and waste water recovery system were evaluated in three separate closed loop tests at NASA/JSC. These tests covered a period from August 1985 to June 1987 in which shower waste water was reclaimed and reused for showering. Test persons showered in a preprototype whole body shower following a protocol similar to that anticipated for the Space Station. Each test was performed by using different water recovery system technologies which included phase change distillation and two separate reverse osmosis processes. These were integrated with post-treatment for the final purification of the reclaimed water. The phase change, a preprototype Thermoelectric Hollow Fiber Membrane Evaporation Subsystem was used for the initial test with chemical pretreatment of the shower waste water input. A reverse osmosis dynamic membrane system was used for the second test and a 2-stage ultrafiltration/reverse osmosis system for the third test.