Refine Your Search

Topic

Search Results

Standard

Turboshaft/Turboprop Gas Turbine Engine Test Cell Correlation

2007-11-15
HISTORICAL
ARP4755A
This paper describes a recommended practice and procedure for the correlation of test cells that are used for the performance testing of turboprop and turboshaft engines. This Aerospace Recommended Practice (ARP) shall apply to both dynamometer and propeller based testing. Test cell correlation is performed to determine the effect of any given test cell enclosure and equipment on the performance of an engine relative to the baseline performance of that engine.
Standard

Turboshaft/Turboprop Gas Turbine Engine Test Cell Correlation

2023-05-19
CURRENT
ARP4755C
This paper describes a recommended practice and procedure for the correlation of test cells that are used for the performance testing of turboprop and turboshaft engines. This Aerospace Recommended Practice (ARP) shall apply to both dynamometer and propeller based testing. Test cell correlation is performed to determine the effect of any given test cell enclosure and equipment on the performance of an engine relative to the baseline performance of that engine. Although no original equipment manufacturer (OEM) documents are actually referenced, the experience and knowledge of several OEMs contributed to the development of this document. Each engine manufacturer has their own practices relating to correlation and they will be used by those OEMS for the purpose of establishing certified test facilities.
Standard

Turboshaft/Turboprop Gas Turbine Engine Test Cell Correlation

2013-12-19
HISTORICAL
ARP4755B
This paper describes a recommended practice and procedure for the correlation of test cells that are used for the performance testing of turboprop and turboshaft engines. This Aerospace Recommended Practice (ARP) shall apply to both dynamometer and propeller based testing. Test cell correlation is performed to determine the effect of any given test cell enclosure and equipment on the performance of an engine relative to the baseline performance of that engine.
Standard

Turbofan and Turbojet Gas Turbine Engine Test Cell Correlation

2023-05-01
CURRENT
ARP741D
This SAE Aerospace Recommended Practice (ARP) describes a recommended practice and procedure for the correlation of test cells that are used for the performance testing of turbofan and turbojet engines. Test cell correlation is performed to determine the effect of any given test cell enclosure and equipment on the performance of an engine relative to the baseline performance of that engine. When baseline testing is performed in an indoor test cell, the baseline performance data are adjusted to open air conditions. Although no original equipment manufacturer (OEM) documents are actually referenced, the experience and knowledge of several OEM’s contributed to the development of this document. Each engine Manufacturer has their own practices relating to correlation and they will be used by those OEMs for the purpose of establishing certified test facilities.
Standard

Turbofan and Turbojet Gas Turbine Engine Test Cell Correlation

2016-08-12
HISTORICAL
ARP741C
This paper describes a recommended practice and procedure for the correlation of test cells that are used for the performance testing of turbofan and turbojet engines. Test cell correlation is performed to determine the effect of any given test cell enclosure and equipment on the performance of an engine relative to the baseline performance of that engine. When baseline testing is performed in an indoor test cell, the baseline performance data are adjusted to open air conditions. Although no original equipment manufacturer (OEM) documents are actually referenced, the experience and knowledge of several OEMs contributed to the development of this document. Each engine Manufacturer has their own practices relating to correlation and they will be used by those OEMS for the purpose of establishing certified test facilities.
Standard

Turbofan and Turbojet Gas Turbine Engine Test Cell Correlation

1999-05-01
HISTORICAL
ARP741A
This paper describes a recommended practice and procedure for the correlation of test cells that are used for the performance testing of turbofan and turbojet engines. Test cell correlation is performed to determine the effect of any given test cell enclosure and equipment on the performance of an engine relative to the baseline performance of that engine. When baseline testing is performed in an indoor test cell, the baseline performance data are adjusted to open air conditions.
Standard

Turbofan and Turbojet Gas Turbine Engine Test Cell Correlation

2008-11-05
HISTORICAL
ARP741B
This paper describes a recommended practice and procedure for the correlation of test cells that are used for the performance testing of turbofan and turbojet engines. Test cell correlation is performed to determine the effect of any given test cell enclosure and equipment on the performance of an engine relative to the baseline performance of that engine. When baseline testing is performed in an indoor test cell, the baseline performance data are adjusted to open air conditions.
Standard

Turbine Flowmeter Fuel Flow Calculations

2013-10-04
HISTORICAL
ARP4990A
This SAE Aerospace Recommended Practice (ARP) provides to the aerospace industry a procedure for the consistent and accurate calculation of fuel flow using turbine flowmeters during development, production, and post overhaul/repair gas turbine engine testing.
Standard

Turbine Flowmeter Fuel Flow Calculations

2020-10-22
CURRENT
ARP4990B
This SAE Aerospace Recommended Practice (ARP) provides to the aerospace industry a procedure for the consistent and accurate calculation of fuel flow using turbine flowmeters during development, production, and post overhaul/repair gas turbine engine testing.
Standard

Test Facility Shakedown and Commissioning

2023-05-17
WIP
AIR6364A
The paper will concentrate on the main engineering engine related aspects of the facility and will not necessarily contain information on the construction validation activities such as HVAC, electrical, facility fire system, waste water etc.
Standard

Test Facility Shakedown and Commissioning

2017-11-29
CURRENT
AIR6364
The paper discusses in general terms the activities required to be undertaken or demonstrated during the establishment of the facility such as: the assessment checks prior to forwarding to the end users site for embodiment into the facility system the establishment of the facility such as trial installations of hardware, functionality checking of lifting transportation and access systems, centerline pull checks, pressure testing of fuel and air start systems, flushing of wet systems and electrical continuity checking. the commissioning of the facility such as instrumentation calibrations, engine starts, engine running, assessment of command and control system, assessment of DAS system, aerodynamic and acoustic surveys. The paper will concentrate on the main engineering engine related aspects of the facility and will not necessarily contain information on the construction validation activities such as HVAC, electrical, facility fire system, waste water etc.
Standard

Test Cell Thrust Measurement

2017-02-13
HISTORICAL
AIR4951
Thrust measurement systems come in many sizes and shapes, with varying degrees of complexity, accuracy and cost . For the purposes of this information report, the discussions of thrust measurement will be limited to axial thrust in single-axis test systems.
Standard

Test Cell Mass Fuel Flow Measurement Using Coriolis Flow Meters

2017-06-14
CURRENT
AIR6202
The scope of this information report applies to the steady state measurement of direct mass fuel flow in gas turbine engine test cells. A measurement accuracy, and hence uncertainty of between ±0.1 to ±0.2% of value is believed to be achievable for liquid flow applications with some meter models/installations. Whilst capable of general transient measurement in 50 to 100 Hz region, this type of fuel meter is not capable of rapid transient measurement (in 100 to 250 Hz region). It is also not currently considered suitable for "in flight" fuel flow measurement.
Standard

Test Cell Mass Fuel Flow Measurement Using Coriolis Flow Meters

2022-10-05
WIP
AIR6202A

The scope of this information report applies to the steady state measurement of direct mass fuel flow in gas turbine engine test cells. A measurement accuracy, and hence uncertainty of between ±0.1 to ±0.2% of value is believed to be achievable for liquid flow applications with some meter models/installations.

Whilst capable of general transient measurement in 50 to 100 Hz region, this type of fuel meter is not capable of rapid transient measurement (in 100 to 250 Hz region). It is also not currently considered suitable for "in flight" fuel flow measurement.

Standard

Test Cell Instrumentation

2011-08-01
HISTORICAL
AIR5026A
This document discusses, in broad general terms, typical present instrumentation practice for post-overhaul gas turbine engine testing. Production engine testing and engine development work are outside the scope of this document as they will typically use many more channels of instrumentation, and in most cases will have requirements for measurements that are never made in post-overhaul testing, such as fan airflow measurements, or strain measurements on compressor blades. The specifications for each parameter to be measured, in terms of measurement range and measurement accuracy, are established by the engine manufacturers. Each test cell instrument system should meet or exceed those requirements. Furthermore, each instrument system should be recalibrated regularly, to ensure that it is still performing correctly.
Standard

Test Cell Instrumentation

2020-10-21
CURRENT
AIR5026B
This document discusses, in broad general terms, typical present instrumentation practice for post-overhaul gas turbine engine testing. Production engine testing and engine development work are outside the scope of this document as they will typically use many more channels of instrumentation, and in most cases will have requirements for measurements that are never made in post-overhaul testing, such as fan airflow measurements, or strain measurements on compressor blades. The specifications for each parameter to be measured, in terms of measurement range and measurement accuracy, are established by the engine manufacturers. Each test cell instrument system should meet or exceed those requirements. Furthermore, each instrument system should be recalibrated regularly, to ensure that it is still performing correctly.