Refine Your Search

Topic

Author

Affiliation

Search Results

Technical Paper

“Smart Panel” Electronic Circuit Breaker Control Technology

2008-11-11
2008-01-2880
This paper will discuss using Astronics “Smart Panel” illuminated control panels to control an electronic power distribution system. A discussion of wiring simplification, automatic control possibilities and real time load monitoring is presented. The challenges of retrofitting the system into older aircraft will be covered as well. The paper also explains Electronic Circuit Breaker technology, arc fault protection, panel lighting technologies, control bus options, displays, and human input technology (buttons and knobs).
Technical Paper

“Derivation of Conduction Heat Transfer in Thin Shell Toroids”

2000-07-10
2000-01-2487
This paper presents the derivation of the equations for circumferential, longitudinal and radial heat transfer conductance for a thin shell toroid or a segment of the toroid. A thin shell toroid is one in which the radius to thickness ratio is greater than 10. The equations for the surface area of a toroid or of a toroidal segment will also be derived along with the equation to determine the location of the centroid. The surface area is needed to determine the radial conductance in the toroid or toroidal segment and the centroid is needed to determine the heat transfer center of the toroid or toroidal segment for circumferential and longitudinal conductance. These equations can be used to obtain more accurate results for conductive heat transfer in toroid which is a curved spacecraft components. A comparison will be made (1) using the equations derived in this paper which takes into account the curvature of the toroid (true geometry) and (2) using flat plates to simulate the toroid.
Technical Paper

“Condensation – Why it Needs to be Addressed in Every Aircraft”

2003-09-08
2003-01-3000
A wide body aircraft carries almost a half–ton of water and ice between the cabin and skin of the aircraft. The water can get on wires and connectors, which can cause electrical problems, cause corrosion and rust, and, eventually, “rain in the plane”. The speaker is the CEO of CTT Systems that has developed a system that solves the condensation by using dry air. The speaker will discuss how condensation can be prevented and how airlines can also save maintenance costs in the process. This topic is relevant for the attendees at the Aerospace Expo, as they are decision makers who need to be aware of this issue. It is also important for the MRO shows as the attendees are on the front lines of dealing with this problem.
Technical Paper

“A Dry Aircraft is a Safer Aircraft – Beating Condensation by Using Dry Air”

2003-09-08
2003-01-3017
The airline industry seems to be providing more leisure features on planes like inflight entertainment, Internet access and Digital TV, but it seems the airline industry has ignored the issue of excess condensation on aircraft, which had plagued carriers since the birth of the airline industry. How safe are passengers when a wide body aircraft carries in excess almost a half ton of water and ice between the cabin and skin of the aircraft? Besides the added weight straining the aircraft, excess condensation soaks wires and connectors which can cause electrical shorts. There have been instances of emergency doors frozen shut, locked by ice stemming from excess water dripping inside the plane. Extra water also causes “rain-in-the-plane”, an issue that has gained national attention and causes passenger discomfort. It's time for the industry to address what has become a serious issue.
Technical Paper

‘Issues and Behaviors of Airborne Particulate Matters under Microgravity Environment’

2004-07-19
2004-01-2328
During several ISS missions, there were false alarms at both US and Russian smoke detectors. High local airborne particulate concentrations and interior deposits are considered the causes for such anomalies. Alternatives are proposed to replace or complement these faulty smoke detectors. The entrained zeolite particles may play a role in causing problems with check valves and air save pumps in CDRA and Vozdukh. Another incidence has been the dispersion of particulates out of Metox regeneration oven. Particulate matters with aerodynamic diameter of 15 microns and above, which normally settle down on earth, stay airborne under micro-gravity and thereby cause the above-mentioned nuisances. The motion of such a particle along a gas stream with an initial velocity can be expressed by theoretical equations. Stokes' Law leads to the descriptions of inertial precipitation of aerosols that are important in solving the issues.
Technical Paper

‘Bigelow Aerospace® Life Support Laboratory - Planning and Status’

2004-07-19
2004-01-2474
This Life Support Laboratory consists of a simulator of the spacecraft called Nautilus, which houses Air Revitalization Subsystem, Atmospheric Control and Supply, and Fire Detection and Suppression in the Equipment Area. There are supporting facilities including a Human Metabolic Simulator, simulated Low and Moderate Temperature Coolant Loop, chemical analysis bench, purified water supply, vacuum and gas supplies. These facilities are scheduled to be completed and start to operate for demonstration purposes by March 2005. There are an ARES Ground Model (AGM) and a Trace Contaminant Control Assembly in the ARS. The latter will be integrated with the AGM and a Condensing Heat Exchanger. The unit of AGM is being engineered, built, and will be delivered in early 2005 by EADS Space Division. These assemblies will be operated for sensitivity analysis, integration and optimization studies. The main goal is the achievement for optimal recovery of oxygen.
Technical Paper

some development problems with Large Cryogenic Propellant Systems

1960-01-01
600022
HEAT TRANSFER causes loading and starting design problems in large missile systems powered by cryogenic propellants. This manifests itself during loading as effective density variation, violent surface conditions, boiloff, and ice formation — problems which may be solved by insulating the tank. During starting it causes overheating and caviation — effects which may be reduced by recirculators and subcooled charge injections. The study described in this paper centers around liquid oxygen and its variations in heat flux rate, which affect liquid density, surface condition, and replenishing requirements. The problem areas are made apparent by consideration of a hypothetical missile system.*
Technical Paper

Zone of Influence of Porous Suction Tubes in Condensing Heat Exchanger for Space Systems

2008-06-29
2008-01-2075
A “next generation” condensing heat exchanger for space systems has to satisfy demanding operational requirements under variable thermal and moisture loads and reduced gravity conditions. Mathematical models described here are used to investigate transient behavior of wetting and de-wetting dynamics in the binary porous system of porous tubes and porous cold plate. The model is based on the Richard's equation simplified for the zero-gravity conditions. The half-saturation distance or the zone of influence of the porous annular suction tubes on the cold-plate porous material will be in the range of 1 to 10 cm for the time scales ranging from 100 to 10,000 seconds and moisture diffusivity in the range of D = 10-4 to 10-6 m2/s.
Technical Paper

Zero Gravity Phase Separator Technologies - Past, Present and Future

1992-07-01
921160
Spacecraft life support equipment is often challenged with two phase flow, where liquid and gas exist together. In the zero gravity environment of an orbiting spacecraft, the behavior of a liquid/gas interface is dominated by forces not usually observed in one “G” due to the overwhelming effects of gravity. The normal perceptions no longer apply. Water does not run down hill and bubbles do not rise to the surface. Surface energy, capillary forces, wetting characteristics and momentum effects predominate. Techniques and equipment have been developed to separate the liquid/gas mixture into its constituent parts with various levels of efficiency and power consumption.
Technical Paper

ZERO-ODP REFRIGERANTS FOR LOW TONNAGE CENTRIFUGAL CHILLER SYSTEMS

1996-05-01
961320
This paper investigates the use of several zero-ozone depleting potential (zero-ODP) HFC refrigerants, including HFC-134a, HFC-227ca, HFC-227ea, HFC-236ea, HFC-236cb, HFC-236fa, HFC-245cb, and HFC-254cb, for centrifugal chiller applications. We took into account the thermodynamic properties of the refrigerant and aerodynamic characteristics of the impeller compression process in this evaluation.. For a given operating temperature lift, there are significant differences in the pressure ratio required by each refrigerant and this variation in pressure ratio directly affects compressor size, efficiency, and performance. A comparison of the HFC refrigerant candidates with CFC-114 shows that HFC-236ea, HFC-227ca and HFC-227ea are viable alternatives for centrifugal water chillers. HFC-236ea has properties closest to CFC-114, and will result in comparible performance, but will require a slightly larger impeller and a purge system.
Technical Paper

YA-10B Single Seat Night Attack: Lessons Learned

1984-10-01
841632
This paper presents lessons learned from flight testing of the YA-10B Single Seat Night Attack (SSNA) testbed. The generic night attack avionics suite in the YA-10B was used to provide a workload baseline for use in future night attack programs. Pilot rating scales and physiological data were used to construct the workload data base.
Technical Paper

X-Ray - A Necessary Tool for Detecting Incipient Structural Failures in Service Aircraft

1964-01-01
640510
X-ray is an indispensable aid in locating and determining the extent of incipient failures in structure which is inaccessible by position or covered by multiple layers of metal. It is also the most feasible method for checking oil coolers for contamination; bonded honeycomb panels for water; fuel lines for erosion; and with a 360 deg emission tube, fuselage frames for structural integrity without removing the interior upholstery and panels from the passenger compartment or cargo compartments.
Technical Paper

X-29 Fuel/Auxiliary Oil Systems Thermal Management

1986-07-14
860913
The X-29 Fuel/Auxiliary Oil Thermal Management System provides total aircraft accessory oil cooling, including both flight and combined hydraulics, Integrated Drive Generator oil, and Accessory Drive Gearbox oil, with onboard fuel. Fuel cooling rates that are independent of engine demand are achieved through the use of a recirculation loop. Recirculation is minimized by maintaining the engine fuel inlet temperature at the maximum allowable. Fuel cooling results in lower, more uniform subsystem oil temperatures, less ram drag, and smaller, lighter-weight heat exchangers. Initial design studies and laboratory development testing will be discussed, along with comparisons of analytical predictions with flight test results.
Technical Paper

Workload and Situation Awareness in Future Aircraft

1987-10-01
871803
Cockpits have changed dramatically over the last ten years. The electro-mechanical instruments have largely been replaced with electro-optical controls and displays. This change in the pilot-vehicle interface, coupled with a second development, the emergence of a very powerful airborne computer system, an Electronic Crewmember, has had a significant impact on workload in the cockpit. Workload has shifted from physical to mental, and many workload measurement tools applied previously may no longer be appropriate. This paper discusses the prediction, real time measurement and dynamic allocation of cockpit workload in an aircraft with a crew of two -- one human and one electronic.
Technical Paper

Working Fluid De-freezing in Radiator on Base of LHP

2007-07-09
2007-01-3199
Selection of working fluid is one of the main criterions for designing of heat pipes thermal control systems (TCS) for space application. In this paper we will describe how we solved the task of development of the TCS with working fluid of high thermal physical properties. In 2004-2006 we developed the Engineering model of Deployable Radiator based on Loop Heat Pipe by CAST purchase order. It was developed for qualification tests. Ammonia application as LHP working fluid is stipulated by its high thermal physical properties. However Ammonia freezing temperature is of minus 77ºC. Such fact impedes Ammonia application when operation temperatures of LHP Radiator are lower than this value, for example, It takes several tens of hours to orbit a spacecraft and prepare it for work (at that moment the spacecraft is out of power supply) and the working fluid can be frozen in a condenser-radiator when the spacecraft being in the shadow over a long period of time.
Technical Paper

Work/Control Stations in Space Station Weightlessness

1990-07-01
901203
Relating to yet beyond the requirements of putting controls and displays at selected and selectable locations in the station, and to associated subsystem interfaces, is the ergonomic integration of these elements with the operator, and ALL with the diverse, proximal station architecture. Basic to optimal, long-term solutions to this integration is the requirement of the felicitous accommodation of a range of crew sizes from a 5% tile Asian female to a 95% tile Caucasian male. No less important is for the workstation's layout and architecture being optimized for the “new-shape-of-man” - the “neutral body position” - in weightlessness and with the associated geometry and dynamics of this significantly altered state, its capabilities and its new facility. This paper previews the on-going status, development and details of a body-ported workstation prototype and its semi stand-alone elements.
Technical Paper

Wireless Integrated Cockpit Information Display: The Underlying Technologies

2007-09-17
2007-01-3904
The Wireless Integrated Cockpit Information Display (WICID) program originated as a request to remotely control and display laptop based applications from a cockpit without use of the standard keyboard and mouse devices. The resulting system utilized multifunction displays to allow control and display from a single device. The foundations of this system are divided into three technologies: 1) remote display, 2) customized input interface, and 3) application control. This modular approach provides a highly flexible and extendible system capable of remotely controlling several Microsoft Windows based applications, hosted across several processors, without requiring any modifications to those applications.
X