Refine Your Search

Topic

Author

Affiliation

Search Results

Technical Paper

“SODART” Telescope Silicon Detector Cooling System (Thermal Test Results of the Scale-Down Model)

1992-07-01
921365
The onboard “SODART” telescope silicon detector cooling system of the “Spectrum-X-Gamma” observatory, which is designed for the space objects X-ray radiation study, is described. The scale-down model of the passive cooling system description and thermal vacuum test results of this model are given. In the real cooling system the minimal detector temperature at 300 mW heat release is expected about 107 K.
Technical Paper

“Rigidization-on-Command”™ (ROC) Resin Development for Lightweight Isogrid Booms with MLI

2003-07-07
2003-01-2342
The “Rigidization-on-Command”™ (ROC™) resin development has focused on the development of resin systems that use UV light cure for rigidization. Polymeric sensitizers have been incorporated into the resin formulations to promote cure using Pen-Ray lamps and UV light-emitting diodes (LED's). Formulations containing the polymeric sensitizers were examined by FTIR and DSC. Complete cure was observed after 15 min. exposure with the Pen-Ray lamps. Performance of the Pen-Ray lamps and UV LEDs was thoroughly characterized. Thermal models were developed to optimize the performance of the of the MLI insulation thermal oven used for orbital cure of the boom. Results show that -12°C is the lowest temperature required for cure of the ROC™ resin systems.
Technical Paper

eROSITA Camera Low Temperature Thermal Control

2008-01-29
2008-01-1957
eROSITA (extended ROentgen Survey with an Imaging Telescope Array) is a powerful X-ray telescope under development by the Max-Planck-Institut für extraterrestrische Physik (MPE) in Garching, Germany. eROSITA is the core instrument on the Russian SRG1 mission which is planned for launch in 2011. It comprises seven nested Wolter-I grazing incidence telescopes, each equipped with its own CCD camera. The mirror modules have to be maintained at 20°C while the cameras are operated at -80°C. Both, mirrors and CCDs have to be kept within tight limits. The CCD cooling system consists of passive thermal control components only: two radiators, variable conductance heat pipes (VCHP) and two special thermal storage units. The orbit scenario imposes severe challenges on the thermal control system and also on the attitude control system.
Technical Paper

byteflight~A new protocol for safety-critical applications

2000-06-12
2000-05-0220
The permanently increasing number of convenience and safety functions leads to higher complexity of in-car electronics and the rapidly growing amount of sensors, actuators and electronic control units places higher demands on high- speed data communication protocols. Safety-critical systems need deterministic protocols with fault-tolerant behavior. The need for on-board diagnosis calls for flexible use of bandwidth and an ever-increasing number of functions necessitates a flexible means of extending the system. None of the communication solutions available on the market until now (like CAN or TTP) have been able to fulfill all these demands. To solve these problems, BMW together with several semiconductor companies has developed a new protocol for safety-critical applications in automotive vehicles.
Technical Paper

Zone of Influence of Porous Suction Tubes in Condensing Heat Exchanger for Space Systems

2008-06-29
2008-01-2075
A “next generation” condensing heat exchanger for space systems has to satisfy demanding operational requirements under variable thermal and moisture loads and reduced gravity conditions. Mathematical models described here are used to investigate transient behavior of wetting and de-wetting dynamics in the binary porous system of porous tubes and porous cold plate. The model is based on the Richard's equation simplified for the zero-gravity conditions. The half-saturation distance or the zone of influence of the porous annular suction tubes on the cold-plate porous material will be in the range of 1 to 10 cm for the time scales ranging from 100 to 10,000 seconds and moisture diffusivity in the range of D = 10-4 to 10-6 m2/s.
Technical Paper

You-Are-Here Maps for International Space Station: Approach and Guidelines

2004-07-19
2004-01-2584
Guidelines for designing you-are-here (YAH) maps aboard International Space Station (ISS) are proposed, based on results from previous 3D spatial navigation studies conducted by our research group and colleagues. This paper reviews terrestrial YAH maps, the common errors associated with them, and how to appropriately implement what is known from terrestrial to micro-gravity YAH maps. We conclude with a creative example of an ISS YAH map that utilizes given guidelines and information visualization techniques.
Technical Paper

XMM-NEWTON Thermal Design and In-orbit Performance

2000-07-10
2000-01-2372
The XMM-NEWTON satellite is the ESA X-ray spaceborne observatory covering the soft X-ray portion of the electromagnetic spectrum. XMM-NEWTON has been put in orbit on December, 10th 1999 by an Ariane 5 single launch. The spacecraft has a conventional thermal design that takes full advantage of the stable environment provided by its high altitude/long period orbit and by the limited variation of solar attitude angles in order to provide a stable platform for the telescope system. The precise geometry and alignment of the telescope system impose strict temperature requirements so that not only temperature gradients have to be kept small but also, and more importantly, time-variations of the gradients have to be minimised. In the paper, the thermal behaviour of the spacecraft as verified by its thermal test programme is compared with the early in-orbit temperature measurements.
Technical Paper

X-Ray Computed Tomography for Verification of Rivet Installation Assessment Techniques

1998-09-15
982140
High quality rivet installation is of critical importance to the aerospace industry, and the existence of gaps between the rivet head and the countersink is undesirable. Detection of gaps traditionally involves sectioning through rivet joints. Two concerns exist for this method of evaluation: it provides data only from the sectioned plane, and it has potential to alter the gaps. X-ray computed tomography (CT) was used to validate the effectiveness of the tradition sectioning method. It was revealed that the sectioning process generally increased the size of gaps. CT images also revealed that the gaps are not necessarily uniform around the rivet.
X