Refine Your Search

Topic

Author

Affiliation

Search Results

Technical Paper

“Rigidization-on-Command”™ (ROC) Resin Development for Lightweight Isogrid Booms with MLI

2003-07-07
2003-01-2342
The “Rigidization-on-Command”™ (ROC™) resin development has focused on the development of resin systems that use UV light cure for rigidization. Polymeric sensitizers have been incorporated into the resin formulations to promote cure using Pen-Ray lamps and UV light-emitting diodes (LED's). Formulations containing the polymeric sensitizers were examined by FTIR and DSC. Complete cure was observed after 15 min. exposure with the Pen-Ray lamps. Performance of the Pen-Ray lamps and UV LEDs was thoroughly characterized. Thermal models were developed to optimize the performance of the of the MLI insulation thermal oven used for orbital cure of the boom. Results show that -12°C is the lowest temperature required for cure of the ROC™ resin systems.
Technical Paper

“Fuel Flow Method2” for Estimating Aircraft Emissions

2006-08-30
2006-01-1987
In recent years there has been increasing interest in quantifying the emissions from aircraft in order to generate inventories of emissions for climate models, technology and scenario studies, and inventories of emissions for airline fleets typically presented in environmental reports. The preferred method for calculating aircraft engine emissions of NOx, HC, and CO is the proprietary “P3T3” method. This method relies on proprietary airplane and engine performance models along with proprietary engine emissions characterizations. In response and in order to provide a transparent method for calculating aircraft engine emissions non proprietary fuel flow based methods 1,2,3 have been developed. This paper presents derivation, updates, and clarifications of the fuel flow method methodology known as “Fuel Flow Method 2”.
Technical Paper

“Condensation – Why it Needs to be Addressed in Every Aircraft”

2003-09-08
2003-01-3000
A wide body aircraft carries almost a half–ton of water and ice between the cabin and skin of the aircraft. The water can get on wires and connectors, which can cause electrical problems, cause corrosion and rust, and, eventually, “rain in the plane”. The speaker is the CEO of CTT Systems that has developed a system that solves the condensation by using dry air. The speaker will discuss how condensation can be prevented and how airlines can also save maintenance costs in the process. This topic is relevant for the attendees at the Aerospace Expo, as they are decision makers who need to be aware of this issue. It is also important for the MRO shows as the attendees are on the front lines of dealing with this problem.
Technical Paper

“A Dry Aircraft is a Safer Aircraft – Beating Condensation by Using Dry Air”

2003-09-08
2003-01-3017
The airline industry seems to be providing more leisure features on planes like inflight entertainment, Internet access and Digital TV, but it seems the airline industry has ignored the issue of excess condensation on aircraft, which had plagued carriers since the birth of the airline industry. How safe are passengers when a wide body aircraft carries in excess almost a half ton of water and ice between the cabin and skin of the aircraft? Besides the added weight straining the aircraft, excess condensation soaks wires and connectors which can cause electrical shorts. There have been instances of emergency doors frozen shut, locked by ice stemming from excess water dripping inside the plane. Extra water also causes “rain-in-the-plane”, an issue that has gained national attention and causes passenger discomfort. It's time for the industry to address what has become a serious issue.
Technical Paper

some development problems with Large Cryogenic Propellant Systems

1960-01-01
600022
HEAT TRANSFER causes loading and starting design problems in large missile systems powered by cryogenic propellants. This manifests itself during loading as effective density variation, violent surface conditions, boiloff, and ice formation — problems which may be solved by insulating the tank. During starting it causes overheating and caviation — effects which may be reduced by recirculators and subcooled charge injections. The study described in this paper centers around liquid oxygen and its variations in heat flux rate, which affect liquid density, surface condition, and replenishing requirements. The problem areas are made apparent by consideration of a hypothetical missile system.*
Technical Paper

Working Fluid De-freezing in Radiator on Base of LHP

2007-07-09
2007-01-3199
Selection of working fluid is one of the main criterions for designing of heat pipes thermal control systems (TCS) for space application. In this paper we will describe how we solved the task of development of the TCS with working fluid of high thermal physical properties. In 2004-2006 we developed the Engineering model of Deployable Radiator based on Loop Heat Pipe by CAST purchase order. It was developed for qualification tests. Ammonia application as LHP working fluid is stipulated by its high thermal physical properties. However Ammonia freezing temperature is of minus 77ºC. Such fact impedes Ammonia application when operation temperatures of LHP Radiator are lower than this value, for example, It takes several tens of hours to orbit a spacecraft and prepare it for work (at that moment the spacecraft is out of power supply) and the working fluid can be frozen in a condenser-radiator when the spacecraft being in the shadow over a long period of time.
Technical Paper

Workforce Enterprise Modeling

2007-09-17
2007-01-3834
Currently, many factors influence the NASA Kennedy Space Center (KSC) workforce. These factors include the drive for return to flight, a Shuttle Program end date of 2010, and the Vision for Space Exploration which calls for the development of a new launch vehicle. Additionally, external factors exist as well, such as the area's cost of living, the availability of skilled resources, and the unemployment rate affect the overall workforce climate. To manage the human capital in a manner consistent with safety and mission success, and to strategically position NASA KSC to execute its future mission, it is necessary to understand how all of these different influencing factors work together to produce an overall workforce climate. We have been using System Dynamics models in order to capture some of these factors. These system dynamics models are also the starting point of agent-based models.
Standard

Wire, Electrical, Solderless Wrap, Insulated and Uninsulated, General Specification For

2011-07-18
CURRENT
AS81822A
This specification covers both insulated and uninsulated solid conductor wire, designed for solderless wrap connections in electrical and electronic devices and equipment. The terminations of the wire are intended to be made with hand or automatic tools which wrap the wire, under tension, around terminal pins (commonly called wrapposts) to form solderless wrapped connections.
Standard

Wire, Electrical, Solderless Wrap, Insulated and Uninsulated, General Specification For

2004-06-22
HISTORICAL
AS81822
This specification covers both insulated and uninsulated solid conductor wire, designed for solderless wrap connections in electrical and electronic devices and equipment. The terminations of the wire are intended to be made with hand or automatic tools which wrap the wire, under tension, around terminal pins (commonly called wrapposts) to form solderless wrapped connections.
X