Theoretical and Experimental Analysis of Ash Accumulation and Mobility in Ceramic Exhaust Particulate Filters and Potential for Improved Ash Management

2014-04-01
2014-01-1517
Ash accumulation in the channels of ceramic, honeycomb-type particulate filters is controlled by several key parameters, which are the focus of this study. Ultimately, it is the formation of ash deposits, their transport, and the manner in which the ash accumulates in the particulate filter, which determines the useful service life of the filter and its resulting impact on engine performance. Although significant variations in ash deposit properties and their spatial distribution within the filter channels have been reported, depending on the filter's application, understanding the key parameters and mechanisms, such as the effects of exhaust flow and temperature conditions, as well as the processes occurring during filter regeneration events (whether passive or active) are critical in developing improved filter ash management strategies.
Technical Paper

The Sensitivity of DPF Performance to the Spatial Distribution of Ash Inside DPF Inlet Channels

2013-04-08
2013-01-1584
Ash inside a honeycomb-configured diesel particulate filter (DPF) inlet channel accumulates both as a cake layer along the channel walls and as a “plug” towards the back of the channel. Experimental studies of DPF ash distribution have shown both an axial variation of deposits along channels and accumulation towards the end plugs. This study evaluates the sensitivity of DPF pressure drop on ash axial distribution and the potential to reduce flow restrictions by controlling and optimizing the spatial distribution of ash inside DPF channels. A computational model has been used in conjunction with experimental data to illustrate the sensitivity of ash spatial distribution on DPF performance. The classical constant-thickness DPF one-dimensional models have substantially been updated to include layer thickness axial variations. Material properties, such as ash characteristics, are provided by recent experiments at the authors' laboratory.
Journal Article

Soot and Ash Deposition Characteristics at the Catalyst-Substrate Interface and Intra-Layer Interactions in Aged Diesel Particulate Filters Illustrated using Focused Ion Beam (FIB) Milling

2012-04-16
2012-01-0836
The accumulation of soot and lubrication-derived ash particles in a diesel particulate filter (DPF) increases exhaust flow restriction and negatively impacts engine efficiency. Previous studies have described the macroscopic phenomenon and general effects of soot and ash accumulation on filter pressure drop. In order to enhance the fundamental understanding, this study utilized a novel apparatus that of a dual beam scanning electron microscope (SEM) and focused ion beam (FIB), to investigate microscopic details of soot and ash accumulation in the DPF. Specifically, FIB provides a minimally invasive technique to analyze the interactions between the soot, ash, catalyst/washcoat, and DPF substrate with a high degree of measurement resolution. The FIB utilizes a gallium liquid metal ion source which produces Ga+ ions of sufficient momentum to directionally mill away material from the soot, ash, and substrate layers on a nm-μm scale.
Journal Article

Sensitivity Analysis of Ash Packing and Distribution in Diesel Particulate Filters to Transient Changes in Exhaust Conditions

2012-04-16
2012-01-1093
Current CJ-4 lubricant specifications place chemical limits on diesel engine oil formulations to minimize the accumulation of lubricant-derived ash in diesel particulate filters (DPF). While lubricant additive chemistry plays a strong role in determining the amount and type of ash accumulated in the DPF, a number of additional factors play important roles as well. Relative to soot particles, whose residence time in the DPF is short-lived, ash particles remain in the filter for a significant fraction of the filter's useful life. While it is well-known that the properties (packing density, porosity, permeability) of soot deposits are primarily controlled by the local exhaust conditions at the time of particle deposition in the DPF, the cumulative operating history of the filter plays a much stronger role in controlling the properties and distribution of the accumulated ash.
Technical Paper

Real-Time Engine and Aftertreatment System Control Using Fast Response Particulate Filter Sensors

2016-04-05
2016-01-0918
Radio frequency (RF)-based sensors provide a direct measure of the particulate filter loading state. In contrast to particulate matter (PM) sensors, which monitor the concentration of PM in the exhaust gas stream for on-board diagnostics purposes, RF sensors have historically been applied to monitor and control the particulate filter regeneration process. This work developed an RF-based particulate filter control system utilizing both conventional and fast response RF sensors, and evaluated the feasibility of applying fast-response RF sensors to provide a real-time measurement of engine-out PM emissions. Testing with a light-duty diesel engine equipped with fast response RF sensors investigated the potential to utilize the particulate filter itself as an engine-out soot sensor.
Technical Paper

Particulate Matter Characterization of Reactivity Controlled Compression Ignition (RCCI) on a Light Duty Engine

2014-04-01
2014-01-1596
Low temperature combustion (LTC) has been shown to yield higher brake thermal efficiencies with lower NOx and soot emissions, relative to conventional diesel combustion (CDC). However, while demonstrating low soot carbon emissions it has been shown that LTC operation does produce particulate matter whose composition appears to be much different than CDC. The particulate matter emissions from dual-fuel reactivity controlled compression ignition (RCCI) using gasoline and diesel fuel were investigated in this study. A four cylinder General Motors 1.9L ZDTH engine was modified with a port-fuel injection system while maintaining the stock direct injection fuel system. The pistons were modified for highly premixed operation and feature an open shallow bowl design. RCCI operation was carried out using a certification grade 97 research octane gasoline and a certification grade diesel fuel.
Technical Paper

Particulate Filter Soot Load Measurements using Radio Frequency Sensors and Potential for Improved Filter Management

2016-04-05
2016-01-0943
Efficient aftertreatment management requires accurate sensing of both particulate filter soot and ash levels for optimized feedback control. Currently a combination of pressure drop measurements and predictive models are used to indirectly estimate the loading state of the filter. Accurate determination of filter soot loading levels is challenging under certain operating conditions, particularly following partial regeneration events and at low flow rate (idle) conditions. This work applied radio frequency (RF)-based sensors to provide a direct measure of the particulate filter soot levels in situ. Direct measurements of the filter loading state enable advanced feedback controls to optimize the combined engine and aftertreatment system for improved DPF management. This study instrumented several cordierite and aluminum titanate diesel particulate filters with RF sensors. The systems were tested on a range of light- and heavy-duty applications, which included on- and off-road engines.
Journal Article

On-Board Particulate Filter Failure Prevention and Failure Diagnostics Using Radio Frequency Sensing

2017-03-28
2017-01-0950
The increasing use of diesel and gasoline particulate filters requires advanced on-board diagnostics (OBD) to prevent and detect filter failures and malfunctions. Early detection of upstream (engine-out) malfunctions is paramount to preventing irreversible damage to downstream aftertreatment system components. Such early detection can mitigate the failure of the particulate filter resulting in the escape of emissions exceeding permissible limits and extend the component life. However, despite best efforts at early detection and filter failure prevention, the OBD system must also be able to detect filter failures when they occur. In this study, radio frequency (RF) sensors were used to directly monitor the particulate filter state of health for both gasoline particulate filter (GPF) and diesel particulate filter (DPF) applications.
Technical Paper

Modeling Study of Metal Fiber Diesel Particulate Filter Performance

2015-04-14
2015-01-1047
Sintered metal fiber (SMF) diesel particulate filters (DPF) has more than one order of magnitude lower pressure drop compared to a granular or reaction-born DPF of the same (clean) filtration efficiency. To better understand the filtration process and optimize the filter performance, metal fiber filter models are developed in this study. The major previous theoretical models for clean fibrous filter are summarized and compared with experimental data. Furthermore, a metal fiber DPF soot loading model, using similar concept developed in high efficiency particulate air (HEPA) filter modeling, is built to simulate filter soot loading performance. Compared with experimental results, the soot loading model has relatively good predictions of filter pressure drop and filtration efficiency.
Journal Article

Lubricant-Derived Ash Impact on Gasoline Particulate Filter Performance

2016-04-05
2016-01-0942
The increasing use of gasoline direct injection (GDI) engines coupled with the implementation of new particulate matter (PM) and particle number (PN) emissions regulations requires new emissions control strategies. Gasoline particulate filters (GPFs) present one approach to reduce particle emissions. Although primarily composed of combustible material which may be removed through oxidation, particle also contains incombustible components or ash. Over the service life of the filter the accumulation of ash causes an increase in exhaust backpressure, and limits the useful life of the GPF. This study utilized an accelerated aging system to generate elevated ash levels by injecting lubricant oil with the gasoline fuel into a burner system. GPFs were aged to a series of levels representing filter life up to 150,000 miles (240,000 km). The impact of ash on the filter pressure drop and on its sensitivity to soot accumulation was investigated at specific ash levels.
Technical Paper

Loading and Regeneration Analysis of a Diesel Particulate Filter with a Radio Frequency-Based Sensor

2010-10-25
2010-01-2126
Accurate knowledge of diesel particulate filter (DPF) particulate matter (PM) loading is critical for robust and efficient operation of the combined engine-exhaust aftertreatment system. Furthermore, upcoming on-board diagnostics regulations require on-board technologies to evaluate the status of the DPF. This work describes the application of radio frequency (RF) - based sensing techniques to accurately measure DPF particulate matter levels. A 1.9L GM turbo diesel engine and a DPF with an RF-sensor were studied. Direct comparisons between the RF measurement and conventional pressure-based methods were made. Further analysis of the particulate matter loading rates was obtained with a mass-based total PM emission measurement instrument (TEOM) and DPF gravimetric measurements.
Technical Paper

Intra-Catalyst Reductant Chemistry and Nox Conversion of Diesel Lean Nox Traps at Various Stages of Sulfur Loading

2006-10-16
2006-01-3423
Due to increasingly stringent emissions regulations, Lean NOx Trap (LNT) catalysts are being researched as a potential solution for diesel engine emissions reduction. LNTs are practical for diesel NOx reduction due to their ability to reduce NOx from the O2 rich environment produced by diesel engines. LNTs function by storing NOx on the catalyst surface during efficient lean operation then, under rich conditions, releasing and reducing the trapped NOx. One method of producing this rich environment which regenerates a LNT involves manipulating the fuel injection parameters and throttling the air intake. This process is called in-cylinder regeneration. Experiments will be described here in which a 1.7 L common rail diesel engine has been used to regenerate LNTs at various stages of sulfur exposure, a known poison of the LNT.
Technical Paper

Influence of Material Properties and Pore Design Parameters on Non-Catalyzed Diesel Particulate Filter Performance with Ash Accumulation

2012-09-10
2012-01-1728
Diesel particulate filters (DPF) are a common component in emission-control systems of modern clean diesel vehicles. Several DPF materials have been used in various applications. Silicone Carbide (SiC) is common for passenger vehicles because of its thermal robustness derived from its high specific gravity and heat conductivity. However, a segmented structure is required to relieve thermal stress due to SiC's higher coefficient of thermal expansion (CTE). Cordierite (Cd) is a popular material for heavy-duty vehicles. Cordierite which has less mass per given volume, exhibits superior light-off performance, and is also adequate for use in larger monolith structures, due to its lower CTE. SiC and cordierite are recognized as the most prevalent DPF materials since the 2000's. The DPF traps not only combustible particles (soot) but also incombustible ash. Ash accumulates in the DPF and remains in the filter until being physically removed.
Journal Article

In-Situ Optical Analysis of Ash Formation and Transport in Diesel Particulate Filters During Active and Passive DPF Regeneration Processes

2013-04-08
2013-01-0519
The formation and transport processes governing the build-up of incombustible ash deposits in diesel particulate filters (DPF) are influenced to a large extent by the filter's operating history. More specifically, the regeneration process, whether active, passive, or some variation of the two, has long been assumed to exert significant influence on the resulting ash characteristics. Until recently, only limited circumstantial evidence was available to describe differences in ash properties and distribution impacting DPF performance for filters subjected to different regeneration strategies. This work presents, for the first time, results from a comprehensive series of evaluations with optically-accessible DPF core samples showing the processes controlling the formation, transport, and interaction of the soot and ash deposits over a range of DPF regeneration conditions.
Technical Paper

In-Cylinder Production of Hydrogen During Net-Lean Diesel Operation

2006-04-03
2006-01-0212
Hydrogen (H2) is an excellent reductant, and has been shown to be highly effective when introduced into a variety of catalysts such as three-way catalysts, lean NOx traps (LNTs), and hydrocarbon lean NOx catalysts (also termed hydrocarbon selective catalytic reduction (SCR) catalysts). Furthermore, since lean-burn engines offer improved fuel efficiency yet difficult NOx emission control, H2 production during lean operation for the purpose of NOx reduction could be beneficial. On-board generation of hydrogen is being explored via catalytic or plasma-based reformers. A possible alternative to these add-on systems is generation of the H2 in-cylinder with standard fuel injection hardware. This paper details experiments relating to the production and measurement of H2 under net-lean operation in a common-rail diesel engine. In-cylinder fuel control is used to tailor the combustion process such that H2 is generated while maintaining a lean Air:Fuel ratio in the bulk exhaust gas.
Technical Paper

In-Cylinder Fuel Blending of Gasoline/Diesel for Improved Efficiency and Lowest Possible Emissions on a Multi-Cylinder Light-Duty Diesel Engine

2010-10-25
2010-01-2206
In-cylinder fuel blending of gasoline with diesel fuel is investigated on a multi-cylinder light-duty diesel engine as a strategy to control in-cylinder fuel reactivity for improved efficiency and lowest possible emissions. This approach was developed and demonstrated at the University of Wisconsin through modeling and single-cylinder engine experiments. The objective of this study is to better understand the potential and challenges of this method on a multi-cylinder engine. More specifically, the effect of cylinder-to-cylinder imbalances and in-cylinder charge motion as well as the potential limitations imposed by real-world turbo-machinery were investigated on a 1.9-liter four-cylinder engine. This investigation focused on one engine condition, 2300 rpm, 5.5 bar net mean effective pressure (NMEP). Gasoline was introduced with a port-fuel-injection system.
Technical Paper

Effects of NOX Storage Component on Ammonia Formation in TWC for Passive SCR NOX Control in Lean Gasoline Engines

2018-04-03
2018-01-0946
A prototype three-way catalyst (TWC) with NOX storage component was evaluated for ammonia (NH3) generation on a 2.0-liter BMW lean burn gasoline direct injection engine as a component in a passive ammonia selective catalytic reduction (SCR) system. The passive NH3 SCR system is a potential approach for controlling nitrogen oxides (NOX) emissions from lean burn gasoline engines. In this system, NH3 is generated over a close-coupled TWC during periodic slightly-rich engine operation and subsequently stored on an underfloor SCR catalyst. Upon switching to lean, NOX passes through the TWC and is reduced by the stored NH3 on the SCR catalyst. Adding a NOX storage component to a TWC provides two benefits in the context of a passive SCR system: (1) enabling longer lean operation by storing NOX upstream and preserving NH3 inventory on the downstream SCR catalyst; and (2) increasing the quantity and rate of NH3 production during rich operation.
Journal Article

Direct Measurements of Soot/Ash Affinity in the Diesel Particulate Filter by Atomic Force Microscopy and Implications for Ash Accumulation and DPF Degradation

2014-04-01
2014-01-1486
Inorganic engine lubricant additives, which have various specific, necessary functions such as anti-wear, leave the combustion chamber bound to soot particles (approximately ≤1% by mass) as ash [13], and accumulate in aftertreatment components. The diesel particulate filter (DPF) is especially susceptible to ash-related issues due to its wall-flow architecture which physically traps most of the soot and ash emissions. Accumulated lubricant-derived ash results in numerous problems including increased filter pressure drop and decreased catalytic functionality. While much progress has been made to understand the macroscopic details and effects of ash accumulation on DPF performance, this study explores the nano- and micron-scale forces which impact particle adhesion and mobility within the particulate filter.
Technical Paper

Direct Measurement of Aftertreatment System Stored Water Levels for Improved Dew Point Management Using Radio Frequency Sensing

2019-04-02
2019-01-0739
Reducing cold-start emissions to meet increasingly stringent emissions limits requires fast activation of exhaust system sensors and aftertreatment control strategies. One factor delaying the activation time of current exhaust sensors, such as NOx and particulate matter (PM) sensors, is the need to protect these sensors from water present in the exhaust system. Exposure of the ceramic sensing element to water droplets can lead to thermal shock and failure of the sensor. In order to prevent such failures, various algorithms are employed to estimate the dew point of the exhaust gas and determine when the exhaust system is sufficiently dry to enable safe sensor operation. In contrast to these indirect, model-based approaches, this study utilized radio frequency (RF) sensors typically applied to monitor soot loading levels in diesel and gasoline particulate filters, to provide a direct measurement of stored water levels on the ceramic filter elements themselves.
Technical Paper

Developing Design Guidelines for an SCR Assembly Equipped for RF Sensing of NH3 Loading

2018-04-03
2018-01-1266
The Cu-zeolite (CuZ) SCR catalyst enables higher NOx conversion efficiency in part because it can store a significant amount of NH3. “NH3 storage control”, where diesel exhaust fluid (DEF) is dosed in accord with a target NH3 loading, is widely used with CuZ catalysts to achieve very high efficiency. The NH3 loading actually achieved on the catalyst is currently estimated through a stoichiometric calculation. With future high-capacity CuZ catalyst designs, it is likely that the accuracy of this NH3 loading estimate will become limiting for NOx conversion efficiency. Therefore, a direct measurement of NH3 loading is needed; RF sensing enables this. Relative to RF sensing of soot in a DPF (which is in commercial production), RF sensing of NH3 adsorbed on CuZ is more challenging. Therefore, more attention must be paid to the “microwave resonance cavity” created within the SCR assembly. The objective of this study was to develop design guidelines to enable and enhance RF sensing.