Refine Your Search

Search Results

Viewing 1 to 5 of 5
Technical Paper

A Novel Ultrasonic Intake Air Flow Meter for Test Bed Applications

2013-01-09
2013-26-0118
The development process of a combustion engine is now a days strongly influenced by future emission regulations which require further reduction in fuel consumption and precise control of combustion process based on Intake air measurement, during engine development. Intake air flow meters clearly differentiate themselves from typical industrial gas flow meters because of their ability to measure extremely dynamic phenomenon of combustion engine. Thus, high internal data acquisition rate, short response time, ability to measure pulsating and reverse flows with lower measurement uncertainty are the factors that ensures the reliability of the results without being affected by ambient influences, sensor contamination or sensor aging. The AVL developed FLOWSONIX™ is based on ultrasonic transit time measuring principle with broad-band Capacitive Ultrasonic Transducer (CUT) characterized by an excellent air impedance matching strongly distinguishes itself by fulfilling all those requirements.
Technical Paper

Optimizing Validation Programs with the Load Matrix Method

2004-10-26
2004-01-2668
The AVL Load Matrix is a systematic approach to optimize durability and reliability test programs. It is based on component-specific test acceleration factors and uses damage models as well as statistics. Using the Load Matrix approach helps to achieve complete test programs while avoiding unrealistic over-testing. The paper describes the Load Matrix concept and structure as well as the process of setting up the Load Matrix for a system or component. Examples are provided on damage models, and the procedure to estimate the acceleration factors is discussed.
Technical Paper

Reduction of Testing Time of PTCE/HTOE Tests Based on Real Road Load Profiles

2022-03-29
2022-01-0176
HTOE (High Temperature Operation Endurance) and PTCE (Power Thermal Cycle Endurance) tests are typically performed according automotive group standards, such as LV 124 [1], VW80000 [2], FCA CS.00056 [3] or PSA B21 7130 [4]. The LV 124-2 group standard, composed by representatives of automobile manufacturers like Audi AG, BMW AG, Volkswagen AG and Porsche AG describes a wide range of environmental tests and their requirements. In addition, calculation parameters and a method are given in the standard. These group standard tests are often attributed to IEC 60068-2-2 [5] for HTOE and IEC 60068-2-14 [6] for PTCE. As both of these tests are typically of long duration, fundamentally linked to reliability (therefore requiring a statistically significant number of samples) and of considerable importance to power electronic, they are worthy of additional scrutiny for automotive developers as most automotive development moves towards electrification.
Technical Paper

Subjective Assessment of Roughness as a Basis for Objective Vehicle Interior Noise Quality Evaluation

1999-05-17
1999-01-1850
This paper focuses on psychoacoustical experiments for the assessment of roughness by using vehicle interior noise. The experimental design is carried out carefully to derive reliable data for further analysis with objective parameters. Apart from the acoustical properties of the recording/playback system the different meanings of the word roughness are taken into account, because each person has its own interpretation of ‘roughness’ differing between the phenomenons of roughness, r-roughness, rumble, harshness, fluctuation strength, etc.. An important preparation for psychoacoustical experiments is a clear definition of the sound attribute under investigation by using typical examples. Furthermore, accidental influences of other psychoacoustical parameters like the influence of loudness have to be avoided.
Technical Paper

Tool Based Calibration with the OBDmanager

2010-04-12
2010-01-0249
At the moment the documentation of failure inhibition matrices and the fault path management for different controller types and different vehicle projects are mainly maintained manually in individual Excel tables. This is not only time consuming but also gives a high potential for fault liability. In addition there is also no guarantee that the calibration of these failure inhibition matrices and its fault path really works. Conflicting aims between costs, time and fault liability require a new approach for the calibration, documentation and testing of failure inhibition matrices and the complete Diagnostic System Management (DSM) calibration. The standardization and harmonization of the Diagnostic System Management calibration for different calibration projects and derivates is the first step to reduce time and costs. Creating a master calibration for the conjoint fault paths and labels provides a significant reduction of efforts.
X