Refine Your Search

Search Results

Viewing 1 to 3 of 3
Technical Paper

Interrelationship of Velocity and Chest Compression in Blunt Thoracic Impact to Swine

1981-10-01
811016
As part of a continuing study of thoracic injury resulting from blunt frontal loading, the interrelationship of velocity and chest compression was investigated in a series of animal experiments. Anesthetized male swine were suspended in their natural posture and subjected to midsternal, ventrodorsad impact. Twelve animals were struck at a velocity of 14.5 ± 0.9 m/s and experienced a controlled thoracic compression of either 15, 19, or 24%. Six others were impacted at 9.7 ± 1.3 m/s with a greater mean compression of 27%. For the 14.5 m/s exposures the severity of trauma increased with increasing compression, ranging from minor to fatal. Injuries included skeletal fractures, pulmonary contusions, and cardiovascular ruptures leading to tamponade and hemothorax. Serious cardiac arrhythmias also occurred, including one case of lethal ventricular fibrillation. The 9.7 m/s exposures produced mainly pulmonary contusion, ranging in severity from moderate to critical.
Technical Paper

Performance of a Shoulder Belt and Knee Restraint in Barrier Crash Simulations

1979-02-01
791006
Previous pendulum impact tests have shown that knee joint injuries and tibial-fibular fractures may occur when loads are directed against the lower leg rather than directly against the femur in the knee. In order to further improve our understanding of lower extremity restraint mechanics, simulated frontal barrier crash experiments were conducted with unembalmed human cadavers and an anthropomorphic dummy restrained by a two-point shoulder belt. In the first test, an experimental bolster was specifically positioned so that the cadaver's lower leg would strike the bolster, thus inducing restraining loads entirely below the knee joint. The analysis of occupant kinematics showed that the flexed knee rode over and forward of the low-positioned bolster. Restraint induced considerable shearing load across the knee joint. Bolster measurements indicated a peak load of approximately 4.0 kN per leg which resulted in a contralateral central tear of the posterior cruciate ligaments.
Technical Paper

Test Dummy Interaction with a Shoulder or Lap Belt

1981-10-01
811017
Belt interaction with the dummy's chest or pelvis was investigated during simulated frontal decelerations to develop a better understanding of the mechanics of belt restraint. Hyge sled tests were conducted at acceleration levels of 6-16 g's with a Part 572 dummy forward facing on an automotive bucket seat. Dynamics were compared in similar tests where the dummy was restrained by a conventional shoulder belt or belt segments attached to a modified sternum - a steel sternum with extensions for fixed belt attachments. Tests were also conducted with a conventional lap belt or belt segments fixed to an extension of the H point. Deformation characteristics of the standard and modified thorax were determined for a lateral and superior point load or a belt yoke compression of the sternum. The pelvic structure was also compressed by a lap belt. Our evaluation of test dummy dynamics indicates the following sequence of events with a conventional shoulder belt: 1.)
X