Refine Your Search

Search Results

Viewing 1 to 6 of 6
Technical Paper

A Numerical Methodology to Compute Temperatures of a Rotating Cardan Shaft

2013-04-08
2013-01-0843
In this paper a new numerical methodology to compute component temperatures of a rotating cardan shaft is described. In general temperatures of the cardan shaft are mainly dominated by radiation from the exhaust gas system and air temperatures in the transmission tunnel and underbody. While driving the cardan shaft is rotating. This yields a uniform temperature distribution of the circumference of the shaft. However most simulation approaches for heat protection are nowadays steady-state computations. In these simulations the rotation of the cardan shaft is not considered. In particular next to the exhaust gas system the distribution of the temperatures of the cardan shaft is not uniform but shows hot temperatures due to radiation at the side facing the exhaust gas system and lower temperatures at the other side. This paper describes a new computational approach that is averaging the radiative and convective heat fluxes circumferentially over bands of the cardan shaft.
Technical Paper

A Simulation Method for the Calculation of Water Condensation inside Charge Air Coolers

2021-04-06
2021-01-0226
The automotive industry uses supercharging in combination with various EGR strategies to meet the increasing demand for Diesel engines with high efficiency and low engine emissions. The charge air is heated by the EGR and the compression in the turbocharger to such an extent that high NOx emissions and a reduction in engine performance occurs. For this reason, the charge air cooler cools down the charge air before it enters the air intake manifold. In case of low pressure EGR, the charge air possesses a high moisture content and under certain operating conditions an accumulation of condensate takes place within the charge air cooler. During demanding engine loads, the condensate is entrained from the charge air cooler into the combustion chamber, resulting in misfiring or severe engine damage.
Journal Article

Modeling and Numerical Calculation of Snow Particles Entering the Air Intake of an Automobile

2015-04-14
2015-01-1342
A physically based model to predict the amount of snow which is entering the air intake of an automobile is extremely important for the automotive industry. It allows to improve the air intake system in the development state so that new vehicles can be developed in a shorter time. Using an Eulerian/Lagrangian approach within a commercial CFD-software we set up a model and calculated the snow ingress into an air intake of an automobile. In our numerical investigations we considered different particle shapes when calculating the drag coefficient, different coefficients of restitution and different particle sizes. Furthermore two-way coupling was considered. To obtain key parameters for the simulation, we measured the size of snow particles in the Daimler climatic wind tunnel in Sindelfingen by using a microscope and a measuring device from Malvern. Besides we used mechanical snow traps to determine the snow mass flux in the climatic wind tunnel and on a test area in Sweden.
Technical Paper

Numerical Simulation of the Flow through an Alternator inside an Engine Compartment of a Passenger Car

2009-10-01
2009-01-3068
In this study the numerical simulation of the flow through an alternator inside an engine compartment of a passenger car is investigated. Specifically the interaction of the flow through the alternator with the flow through the engine compartment is explored in detail. The results are compared with a corresponding numerical simulation of an alternator in a surrounding of a test facility and with a numerical simulation of the flow through an engine compartment without taking into account the internal flow through the alternator. Finally the air temperature near the alternator and also the temperature of some components inside the alternator are compared with experimental values measured during a typical load case used for the thermal protection of the passenger car.
Technical Paper

Thermal Behavior of an Electronics Compartment with Respect to Real Driving Conditions

2020-04-14
2020-01-1299
The reliability of electronic components is of increasing importance for further progress towards automated driving. Thermal aging processes such as electromigration is one factor that can negatively affect the reliability of electronics. The resulting failures depend on the thermal load of the components within the vehicle lifetime - called temperature collective - which is described by the temperature frequency distribution of the components. At present, endurance testing data are used to examine the temperature collective for electronic components in the late development stage. The use of numerical simulation tools within Vehicle Thermal Management (VTM) enables lifetime thermal prediction in the early development stage, but also represents challenges for the current VTM processes [1, 2]. Due to the changing focus from the underhood to numerous electronic compartments in vehicles, the number of simulation models has steadily increased.
Journal Article

Use of an Eulerian/Lagrangian Framework to Improve the Air Intake System of an Automobile with Respect to Snow Ingress

2017-03-28
2017-01-1319
A simulation approach to predict the amount of snow which is penetrating into the air filter of the vehicle’s engine is important for the automotive industry. The objective of our work was to predict the snow ingress based on an Eulerian/Lagrangian approach within a commercial CFD-software and to compare the simulation results to measurements in order to confirm our simulation approach. An additional objective was to use the simulation approach to improve the air intake system of an automobile. The measurements were performed on two test sites. On the one hand we made measurements on a natural test area in Sweden to reproduce real driving scenarios and thereby confirm our simulation approach. On the other hand the simulation results of the improved air intake system were compared to measurements, which were carried out in a climatic wind tunnel in Stuttgart.
X