Refine Your Search

Topic

Author

Search Results

Technical Paper

A Miniature Quadrupole Mass Spectrometer Array and GC For Space Flight: Astronaut EVA and Cabin-Air Monitoring

2000-07-10
2000-01-2300
A miniature quadrupole mass spectrometer array and gas chromatograph have been designed and built for NASA flight missions. Without the gas chromatograph the mass spectrometer is to be used for detection, by astronauts in EVA, of N2, O2, the hydrazines, and NH3 leaks in the hull of the International Space Station, and of adsorbed hydrazines on the astronauts’ suits. The fully-adapted astronaut system, with all software and visual readout, is called the Trace Gas Analyzer. When interfaced with the miniature gas chromatographic system, the mass spectrometer will be useful for a variety of NASA missions involving more complex gas mixtures. The missions include planetary exploration (to Venus, Europa, Titan, etc.), as well as cabin-air monitoring for long-duration human flight to the Moon, Mars, and beyond.
Journal Article

ATCC 29669 Spores Show Substantial Dry Heat Survivability

2008-06-29
2008-01-1982
Bacillus sp. ATCC 29669 was isolated from microbial fallout in clean rooms during the assembly of the Viking Spacecraft missions to Mars, making it a potential contamination concern for outbound space missions. Spores from this bacterial strain were found to be thirty times more resistant to dry heat than B. atrophaeus. Spore inactivation rates under vacuum controlled humidity were faster than rates obtained under ambient humidity. Inactivation rates for these heat resistant spores are important considerations for planetary protection implementation where temperature, time and humidity conditions are used to estimate the effectiveness of dry heat microbial reduction (DHMR) procedures.
Technical Paper

Development of Vapor Phase Hydrogen Peroxide Sterilization Process for Spacecraft Applications

2001-07-09
2001-01-2411
In order to meet microbial reduction requirements for all Mars in-situ life detection and sample return missions, entire planetary spacecraft (including planetary entry probes and planetary landing capsules) may have to be exposed to a qualified sterilization process. At JPL, we are developing a low temperature (~45°C) vapor phase hydrogen peroxide sterilization process. This process is currently being used by the medical industry and its effectiveness is well established. In order to effectively and safely apply this technology to sterilize a spacecraft, which is made out of various man-made materials and electronic circuit boards, the following technical issues need to be resolved: 1. Efficacy of sterilization process. 2. Diffusion of H2O2 under sterilization process conditions into hard to reach places. 3. Materials and components compatibility with the sterilization process. 4. Development of methodology to protect (isolate) sensitive components (i.e. electronic ) from H2O2 vapor.
Journal Article

Development of the Orbiting Carbon Observatory Instrument Thermal Control System

2008-06-29
2008-01-2065
The Orbiting Carbon Observatory (OCO) will carry a single science instrument scheduled for launch on an Orbital Sciences Corporation LeoStar-2 architecture spacecraft bus in December 2008. The science objective of the OCO instrument is to collect spaced-based measurements of atmospheric CO2 with the precision, resolution, and coverage needed to identify CO2 sources and sinks and quantify their seasonal variability. The instrument will permit the collection of spatially resolved, high resolution spectroscopic observations of CO2 and O2 absorption in reflected sunlight over both continents and oceans. These measurements will improve our ability to forecast CO2 induced climate change. The instrument consists of three bore-sighted, high resolution grating spectrometers sharing a common telescope with similar optics and electronics.
Technical Paper

Development of the Surface Thermal Environment for the Mars Scout Phoenix Mission

2007-07-09
2007-01-3239
Phoenix is NASA's first Mars Scouts Mission that will place a soft-lander on the Martian surface at a high northern latitude. Much of the Mars surface environmental flight data from landed missions pertains to the near-equatorial regions. However, orbital observations have yielded very useful data about the surface environment. These data along with a simple, but highly effective one-dimensional atmospheric model was used to develop the Phoenix surface thermal environment. As candidate landing sites were identified, parametric studies including statistical variations were conducted to prescribe minimum nighttime and maximum daytime temperature design Sols (a Martian day). Atmospheric effects such as clouds and ice were considered. Finally, recent candidate landing site imaging conducted by the Mars Reconnaissance Orbiter revealed that the prime site contained a much higher rock density than first thought.
Technical Paper

Development of the Third Generation JPL Electronic Nose for International Space Station Technology Demonstration

2007-07-09
2007-01-3149
The capabilities of the JPL Electronic Nose have been expanded to include characteristics required for a Technology Demonstration schedule on the International Space Station (ISS) in 2008-2009 [1,2]. Concurrently, to accommodate specific needs on ISS, the processes, tools and analyses which influence all aspects of development of the device have also been expanded. The Third Generation ENose developed for this program uses two types of sensor substrates, newly developed inorganic and organic sensor materials, redesigned electronics, onboard near real-time data analysis and power and data interfaces specifically for ISS. This paper will discuss the Third Generation ENose with a focus on detection of mercury in the parts-per-billion range.
Technical Paper

Expanding the Capabilities of the JPL Electronic Nose for an International Space Station Technology Demonstration

2006-07-17
2006-01-2179
An array-based sensing system based on polymer-carbon composite conductometric sensors is under development at JPL for use as an environmental monitor in the International Space Station. Sulfur dioxide has been added to the analyte set for this phase of development. Using molecular modeling techniques, the interaction energy between SO2 and polymer functional groups has been calculated, and polymers selected as potential SO2 sensors. Experiment has validated the model and two selected polymers have been shown to be promising materials for SO2 detection.
Technical Paper

Extended Temperature Range Studies for Dry Heat Microbial Reduction

2005-07-11
2005-01-3096
Dry heat microbial reduction is an approved method to reduce the microbial bioburden on space-flight hardware prior to launch to meet flight project planetary protection requirements. Microbial bioburden reduction also occurs if a spacecraft enters a planetary atmosphere (e.g., Mars) and is heated by frictional forces. However, without further studies, administrative credit for this reduction cannot be applied. The killing of Bacillus subtilis var. niger spores has been examined and lethality data has been collected by placing spores in a vacuum oven or thermal spore exposure vessels (TSEV) in a constant temperature bath. Using this lethality data, a preliminary mathematical model is being developed that can be used to predict spore killing at different temperatures. This paper will present the lethality data that has been collected at this time and the planned future studies.
Journal Article

Ground Validation of the Third Generation JPL Electronic Nose

2008-06-29
2008-01-2044
The Third Generation ENose is an air quality monitor designed to operate in the environment of the US Lab on the International Space Station. It detects a selected group of analytes at target concentrations in the ppm regime at an environmental temperature range of 18 - 30 °C, relative humidity from 25 - 75% and pressure from 530 to 760 torr. The abilities of the device to detect ten analytes, to reject confounders as “unknown” and to deconvolute mixtures of two analytes under varying environmental conditions has been tested extensively in the laboratory. Results of ground testing showed an overall success rate for detection, identification and quantification of analytes of 87% under nominal temperature and humidity conditions and 83% over all conditions.
Technical Paper

High Temperature Mechanically Pumped Fluid Loop for Space Applications –Working Fluid Selection

2004-07-19
2004-01-2415
Mechanically pumped single-phase fluid loops are well suited for transporting and rejecting large amounts of waste heat from spacecraft electronics and power supplies. While past implementations of such loops on spacecraft have used moderate operating temperatures (less than 60ºC), higher operating temperatures would allow equivalent heat loads to be rejected by smaller and less massive radiators. A high temperature (100 to 150ºC) mechanically pumped fluid loop is currently being investigated at the Jet Propulsion Laboratory (JPL) for use on future Mars missions. This paper details the trade study used to select the high temperature working fluid for the system and the initial development testing of loop components.
Technical Paper

Mars Exploration Rover Heat Rejection System Performance – Comparison of Ground and Flight Data

2004-07-19
2004-01-2413
Mars Exploration Rover (MER) mission launched two spacecraft to Mars in June and July of 2003 and landed two rovers on Mars in January 2004. A Heat Rejection System (HRS) based on a mechanically pumped single-phase liquid cooling system was used to reject heat from electronics to space during the seven months cruise from Earth to Mars. Even though most of this HRS design was similar to the system used on Mars Pathfinder in 1996, several key modifications were made in the MER HRS design. These included the heat exchanger used in removing the heat from electronics, design of venting system used to vent the liquid prior to Mars entry, inclusion of pressure transducer in the HRS, and the spacecraft radiator design. Extensive thermal/fluids modeling and analysis were performed on the MER HRS design to verify the performance and reliability of the system. The HRS design and performance was verified during the spacecraft system thermal vacuum tests.
Technical Paper

Mars Exploration Rover Surface Mission Flight Thermal Performance

2005-07-11
2005-01-2827
NASA launched two rovers in June and July of 2003 as a part of the Mars Exploration Rover (MER) project. MER-A (Spirit) landed on Mars in Gusev Crater at 15 degrees South latitude and 175 degrees East longitude on January 4, 2004 (Squyres, et al., Dec. 2004). MER-B (Opportunity) landed on Mars in Terra Meridiani at 2 degrees South latitude and 354 degrees East longitude on January 25, 2004 (Squyres, et al., Aug. 2004). Both rovers have well exceeded their design lifetime (90 Sols) by more than a factor of 5. Spirit and Opportunity are still healthy and continue to execute their roving science missions at the time of this writing. This paper discusses rover flight thermal performance during the surface missions of both vehicles, covering roughly the time from the MER-A landing in late Southern Summer (aereocentric longitude, Ls = 328, Sol 1A) through the Southern Winter solstice (Ls = 90, Sol 255A) to nearly Southern Vernal equinox (Ls = 160, Sol 398A).
Technical Paper

Mars Exploration Rover Thermal Test Program Overview

2004-07-19
2004-01-2310
In January 2004, two Mars Exploration Rovers (MER) landed on the surface of Mars to begin their mission as robotic geologists. A year prior to these historic landings, both rovers and the spacecraft that delivered them to Mars, were completing a series of environmental tests in facilities at the Jet Propulsion Laboratory. This paper describes the test program undertaken to validate the thermal design and verify the workmanship integrity of both rovers and the spacecraft. The spacecraft, which contained the rover within the aeroshell, were tested in a 7.5 m diameter thermal vacuum chamber. Thermal balance was performed for the near earth (hot case) condition and for the near Mars (cold case) condition. A solar simulator was used to provide the solar boundary condition on the solar array. IR lamps were used to simulate the solar heat load on the aeroshell for the off-sun attitudes experienced by the spacecraft during its cruise to Mars.
Technical Paper

Mars Pathfinder Active Heat Rejection System: Successful Flight Demonstration of a Mechanically Pumped Cooling Loop

1998-07-13
981684
One of the new technologies successfully demonstrated on the recent Mars Pathfinder mission was the active Heat Rejection System (HRS). This system consisted of a mechanically pumped cooling loop, which actively controlled the temperatures of the various parts of the spacecraft. A single phase Refrigerant 11 liquid was mechanically circulated through the lander and cruise electronics box heat exchangers. This liquid transferred the excess heat to an external radiator on the cruise stage. This is the first time in unmanned spacecraft history that an active heat rejection system of this type has been used on a long duration spacecraft mission. Pathfinder was launched in December 1996 and landed on the Martian surface on July 4, 1997. The system functioned flawlessly during the entire seven months of flight from Earth to Mars. A life test set up of the cooling loop was used to verify the life of the system.
Journal Article

Mars Science Laboratory Mechanically Pumped Fluid Loop for Thermal Control - Design, Implementation, and Testing

2009-07-12
2009-01-2437
The Mars Science Laboratory (MSL) mission to land a large rover on Mars is being prepared for Launch in 2011. A Multi-Mission Radioisotope Thermoelectric Generator (MMRTG) on the rover provides an electrical power of 110 W for use in the rover and the science payload. Unlike the solar arrays, MMRTG provides a constant electrical power during both day and night for all seasons (year around) and latitudes. The MMRTG dissipates about 2000 W of waste heat to produce the desired electrical power. One of the challenges for MSL Rover is the thermal management of the large amount of MMRTG waste heat. During operations on the surface of Mars this heat can be harnessed to maintain the rover and the science payload within their allowable limits during nights and winters without the use of electrical survival heaters. A mechanically pumped fluid loop heat rejection and recovery system (HRS) is used to pick up some of this waste heat and supply it to the rover and payload.
Technical Paper

Mechanically Pumped Fluid Loop Technologies for Thermal Control of Future Mars Rovers

2006-07-17
2006-01-2035
Future planetary science missions planned for Mars are expected to be more complex and thermally challenging than any of the previous missions. For future rovers, the operational parameters such as landing site latitudes, mission life, distance traversed, and rover thermal energy to be managed will be significantly higher (two to five times) than the previous missions. It is a very challenging problem to provide an effective thermal control for the future rovers using traditional passive thermal control technologies. Recent investigations at the Jet Propulsion Laboratory (JPL) have shown that mechanical pump based fluid loops provide a robust and effective thermal control system needed for these future rovers. Mechanical pump based fluid loop (MPFL) technologies are currently being developed at JPL for use on such rovers. These fluid loops are planned for use during spacecraft cruise from earth to Mars and also on the Martian surface operations.
Technical Paper

Microbial Burden of Commercial Aircraft Cabin Air

2005-07-11
2005-01-3087
The microbial burdens of 69 cabin air samples collected in-flight aboard commercial airliners were assessed via culture-dependent and molecular-based microbial enumeration assays. Cabin air samples from each of four separate flights aboard two different carriers were collected via air-impingement. Microbial enumeration techniques targeting DNA, ATP, and endotoxin were employed to estimate total microbial burden. The total viable microbial population ranged from 0 to 3.6 × 104 cells per 100 liters of air, as assessed by the ATP-assay. When these same samples were plated on minimal medium, anywhere from 2 to 80% of the viable population was cultivable. Five of the 29 samples examined exhibited higher cultivable plate counts than ATP-derived viable counts, perhaps a consequence of the dormant nature (lower concentration of intracellular ATP) of cells inhabiting these air cabin samples.
Technical Paper

Monitoring Space Shuttle Air for Selected Contaminants Using an Electronic Nose

1998-07-13
981564
A miniaturized electronic nose has been constructed at JPL in collaboration with Caltech. This array of conductometric sensors has been trained to detect and quantify the presence of vapors in the air; the compounds detected have been found as contaminants in shuttle air. This device has potential application as a miniature, distributed device for monitoring and controlling the constituents in air.
Technical Paper

Noise Environment Reduction Foam Spheres in Space

1989-09-01
892373
The advent of lightweight fairings for new spacecraft and the increased thrust of new launch vehicles have intensified the need for better techniques for predicting and for reducing the low frequency noise environment of spacecraft at lift-off. This paper presents a VAPEPS (VibroAcoustic Payload Environment Prediction System) parametrical analysis of the noise reduction of spacecraft fairings and explores a novel technique for increasing the low frequency noise reduction of lightweight fairings by approximately 10 dB.
Journal Article

On-Orbit Performance of the Moon Mineralogy Mapper Instrument

2009-07-12
2009-01-2390
Launched on India's Chandrayaan-1 spacecraft on October 22, 2008, JPL's Moon Mineralogy Mapper (M3) instrument has successfully completed over six months of operation in space. M3 is one in a suite of eleven instruments, six of which are foreign payloads, flying onboard the Indian spacecraft. Chandrayaan-1, managed by the Indian Space Research Organization (ISRO) in Bangalore, is India's first deep space mission. Chandrayaan-1 was launched on the upgraded version of India's Polar Satellite Launch Vehicle (PSLV-XL) from the Satish Dhawan Space Centre, SHAR, Sriharikota, India. The primary science objective of the M3 instrument is the characterization and mapping of the lunar surface composition in the context of its geologic evolution. Its primary exploration goal is to assess and map the Moon mineral resources at high spatial resolution to support future targeted missions.