Technical Paper

A Sensor for Estimating the Liquid Mass Fraction of the Refrigerant Exiting an Evaporator

2000-03-06
2000-01-0976
A traditional method of controlling evaporator superheat in a vapor compression air conditioning system is the thermostatic expansion valve (TXV). Such systems are often used in automotive applications. The TXV depends on superheat to adjust the valve opening. Unfortunately, any amount of superheat causes that evaporator to operate at reduced capacity due to dramatically lower heat transfer coefficients in the superheated region. In addition, oil circulation back to the compressor is impeded. The cold lubricant almost devoid of dissolved refrigerant is quite viscous and clings to the evaporator walls. A system that could control an air conditioner to operate with no superheat would either decrease the size of its existing evaporator while maintaining the same capacity, or potentially increase its capacity with its original evaporator. Also, oil circulation back to the compressor would be improved.
Technical Paper

An Investigation of the Feasibility of Refrigerant Charge Loss Detection Using Low Cost Measurements

1997-02-24
970106
The feasibility of automatically detecting refrigerant charge loss in mobile air conditioning (MAC) systems by analyzing inexpensive dynamic measurements was studied. An indicator of the refrigerant inventory of the evaporator was developed. This measure, termed Time to Temperature Turning (TTT), is based on dynamic measurement of the evaporator outlet refrigerant temperature, and correlates strongly with charge level. TTT correlated well with clutch cycling behavior, a metric which is employed in current shop diagnostic practice to indicate refrigerant charge loss. Laboratory data were generated from a factorial experiment design on the following factors: condenser air inlet temperature, condenser air flow rate, evaporator air inlet temperature, compressor speed, and refrigerant charge. Experiments to date were conducted with a dry evaporator.
Journal Article

Efficiency Improvement by Separation of Vapor and Liquid in Condenser Headers

2017-03-28
2017-01-0180
This paper introduces the concept of separation of two-phase flow in condenser as a way to improve condenser efficiency. The benefits of vapor-liquid refrigerant separation and the reason why it will improve the condenser performance are explained. Numerical studies are presented on the effects of separation on performance of an R134a microchannel condenser, with the comparison to experiment data. Model predicts that at the same mass flow rate, the exit temperature is lower by 2.2 K in the separation condenser compared with that in the baseline. Up to 9% more flow rate of condensate is also predicted by the model in the separation condenser. Experiment results confirm the same trend. In addition, the reason why a certain circuiting of passes with pre-assumed separation results in the header improves the condenser is investigated by the model and results are presented.
Technical Paper

Experimentally Validated Effects of Separation of Liquid and Vapor on Performance of Condenser and System

2017-03-28
2017-01-0162
This paper presents the results of an experimental study to determine the effect of vapor-liquid refrigerant separation in a microchannel condenser of a MAC system. R134a is used as the working fluid. A condenser with separation and a baseline condenser identical on the air side have been tested to evaluate the difference in the performance due to separation. Two categories of experiments have been conducted: the heat exchanger-level test and the system-level test. In the heat exchanger-level test it is found that the separation condenser condenses from 1.6% to 7.4% more mass flow than the baseline at the same inlet and outlet temperature (enthalpy); the separation condenser condenses the same mass flow to a lower temperature than the baseline condenser does. In the system-level test, COP is compared under the same superheat, subcooling and refrigerating capacity. Separation condenser shows up to 6.6% a higher COP than the baseline condenser.
Technical Paper

Methods for Detection of Lubrication Failure Applied to a Swashplate Compressor

2000-03-06
2000-01-0974
Understanding lubrication failures at the shoe/swashplate contact of automotive swashplate compressors will greatly enhance the reliability of the air conditioning system. Maintaining proper lubrication is not always possible during transient conditions. Therefore, a method for detection of lubricant loss is of great interest to the automotive industry. Three methods for detecting lubrication loss were examined: contact resistance, acoustic emission, and dynamic pressure oscillations. A mobile air conditioning test stand capable of recording many system parameters was used. Oil return to the compressor was monitored using an oil separator and a refrigerant/oil concentration sensor. Data were taken during steady oil return rates and after oil shut off. The electrical contact resistance between the shoe and swashplate was used to indicate changes in the lubrication conditions at this critical interface. Measurements were taken at two oil return rates during steady oil return tests.
Technical Paper

Performance Characteristics of a Mobile Heat Pump System at Low Ambient Temperature

2018-04-03
2018-01-0076
The demand for mobile heat pump systems increases with the growing popularity of electric vehicles. One big challenge of such systems using low pressure refrigerant is the substantial drop of heating capacity at low ambient temperature conditions, when heat is most needed. The low suction density associated with low operating pressure in the evaporator is the major reason for the capacity drop. In extremely low ambient temperature, compressor speed may need to be regulated in order to prevent suction pressure going below atmospheric pressure, hence further reducing heat pumping capability. Other factors like pressure drop induced temperature glide and refrigerant maldistribution in the outdoor evaporator also weakens the system ability to absorb heat from ambient air. This paper presents detailed and in-depth analysis of the performance and limiting factors on low ambient temperature operation of a mobile heat pump system using refrigerant R1234yf.
Technical Paper

Refrigerant Charge Imbalance in a Mobile Reversible Air Conditioning-Heat Pump System

2017-03-28
2017-01-0177
This paper presents the study of refrigerant charge imbalance between A/C (cooling) mode and HP (heating) mode of a mobile reversible system. Sensitivities of cooling and heating capacity and energy efficiency with respect to refrigerant charge were investigated. Optimum refrigerant charge level for A/C mode was found to be larger than that for HP mode, primarily due to larger condenser size in A/C mode. Refrigerant charge retention in components at both modes were measured in the lab by quick close valve method. Modeling of charge retention in heat exchangers was compared to experimental measurements. Effect of charge imbalance on oil circulation was also discussed.