Refine Your Search

Search Results

Viewing 1 to 6 of 6
Technical Paper

Air Flow Characteristics Surrounding Evaporating Transient Diesel Sprays

2002-03-04
2002-01-0499
Airflow characteristics surrounding evaporating transient diesel sprays inside a constant volume chamber under temperatures around 1100 K were investigated using a 6-hole injector and a single-hole injector. Particle Image Velocimetry (PIV) was used to measure the gas velocities surrounding a spray plume as a function of space and time. A conical control surface surrounding the spray plume was chosen as a representative side entrainment surface. The normal velocities crossing the control surface toward the spray plume for single-hole injection sprays were higher than those of 6-hole injection sprays. The velocities tangential to the control surface toward the injector tip for the single-hole injection sprays were lower than those of 6-hole injection sprays. An abrupt increase in tangential velocities near the chamber wall suggests that the recirculation of surrounding gas was accelerated by the spray wall impingement, both for non-evaporating and evaporating sprays.
Technical Paper

Characteristics of Air Flow Surrounding Non-Evaporating Transient Diesel Sprays

2000-10-16
2000-01-2789
Airflow characteristics surrounding non-evaporating transient diesel sprays were investigated using a 6-hole injector. Particle Image Velocimetry (PIV) was used to measure the gas velocities surrounding a spray plume as a function of space and time. A hydraulically actuated, electronically controlled unit injector (HEUI) system was used to supply the fuel into a pressurized constant volume chamber at room temperature. The chamber gas densities in this study were 10 kg/m3, 20 kg/m3 and 30 kg/m3. The injection pressure was 96.5 MPa. Two frequency doubled (532 nm) Nd:YAG lasers were used to create coincident laser sheets to illuminate the test section at two instances after start of injection (ASI). The double exposed images of sprays and Al2O3 seed particles were developed and velocity vectors of the gas surrounding the transient diesel sprays were obtained using a numerical autocorrelation PIV method.
Technical Paper

Effect of Gas Density and the Number of Injector Holes on the Air Flow Surrounding Non-Evaporating Transient Diesel Sprays

2001-03-05
2001-01-0532
The effect of ambient gas density and the number of injector holes on the characteristics of airflow surrounding non-evaporating transient diesel sprays inside a constant volume chamber were investigated using a 6-hole injector. Particle Image Velocimetry (PIV) was used to measure the gas velocities surrounding a spray plume as a function of space and time. A conical control surface surrounding the spray plume was chosen as a representative side entrainment surface. The positive normal velocities across the control surface of single-hole injection sprays were higher than those of 6-hole injection sprays. An abrupt increase in velocities tangential to the control surface near the chamber wall suggests that the recirculation of surrounding gas is accelerated by spray wall impingement.
Technical Paper

Internal Flow in a Scale Model of a Diesel Fuel Injector Nozzle

1992-10-01
922308
An experimental investigation of turbulent flow patterns in a scale model of a high pressure diesel fuel injector nozzle has been conducted. Instantaneous velocity measurements were made in a 50X transparent model of one hole of the injector nozzle using an Aerometrics Phase Doppler Particle Analyzer (PDPA) in the velocity mode. Length to diameter ratio (L/D) values of 1.3, 2.4, 4.9, and 7.7 and inlet radius to diameter ratio (R/D) values of approximately 0 and 0.3 were investigated. Two steady flow average Reynolds numbers (10,500 and 13,300), analogous to fuel injection velocities and sac pressures of approximately 320 and 405 m/s and 67 and 107 MPa (10,000 and 16,000 psi), were investigated. The axial progression of mean and root mean square (rms) axial velocities was obtained for both sharp and rounded inlet conditions and varying L/D. The discharge coefficient was also calculated for each geometry.
Technical Paper

Spectral Characteristics of Turbulent Flow in a Scale Model of a Diesel Fuel Injector Nozzle

1993-03-01
930924
An experimental investigation of the spectral characteristics of turbulent flow in a scale model of a high pressure diesel fuel injector nozzle hole has been conducted. Instantaneous velocity measurements were made in a 50X transparent model of one hole of an injector nozzle using an Aerometrics Phase/Doppler Particle Analyzer (PDPA) in the velocity mode. Turbulence spectra were calculated from the velocity data using the Lomb-Scargle method. Injector hole length to diameter ratio (L/D) values of 1.3, 2.4, 4.9, and 7.7 and inlet radius to diameter ratio (R/D) values of approximately 0 and 0.3 were investigated. Results were obtained for a steady flow average Reynolds number of 10,500, which is analogous to a fuel injection velocity of 320 m/s and a sac pressure of approximately 67 MPa (10,000 psi). Turbulence time frequency spectra were obtained for significant locations in each geometry, in order to determine how geometry affects the development of the turbulent spectra.
Technical Paper

The Effects of Wall Temperature on Flame Structure During Flame Quenching

1994-03-01
940683
The effect of wall temperature on single surface flame quenching and flame structure of an atmospheric premixed methane-air flame was studied. The luminous region of a laminar flame was located at an angle of 45 degrees to a temperature- controlled surface. C2 laser-induced fluorescence was used as an indicator of flame position while Raman spectroscopy was used to determine gas temperature profiles near the surface. These measurements were conducted for wall positions (vertical distance from the surface) ranging from 50 mm to 1.0 mm and wall temperatures ranging from 150 °C to 600 °C. C2 laser-induced fluorescence measurements indicated flame position is affected by the presence of a surface and the surface temperature. Larger C2 fluorescence intensity values were observed for higher wall temperatures at all distances from the surface.
X