Refine Your Search

Topic

Search Results

Standard

Aerospace Information Report for Continuous Flow Oxygen Hose Disconnect Fittings

2009-08-27
HISTORICAL
AIR1358B
This Aerospace Information Report (AIR) indicates those dimensions, deemed critical by the manufacturer to assure proper mating of disconnect hose fittings. The dimensions are critical, but not necessarily complete, in defining these fittings since there are other criteria which must also be met.
Standard

Aerospace Information Report for Continuous Flow Oxygen Hose Disconnect Fittings

2000-10-01
HISTORICAL
AIR1358A
This AIR indicates those dimensions, deemed critical by the manufacturer, which are required to be adhered to so that proper mating of the disconnect hose fitting with the correct disconnect be accomplished. The dimensions are critical, but not necessarily complete, in defining these fittings since there are other criteria which must also be met.
Standard

CONTINUOUS FLOW CHEMICAL OXYGEN GENERATORS

1993-12-01
HISTORICAL
AS1304
This Aerospace Standard (AS) provides recommended design guidelines for composition formation, performance, testing and reliability of metal-chlorate-perchlorate class solid chemical oxygen generators, supplying oxygen at essentially ambient pressure, for aircraft whose cabin pressure altitude does not exceed 40,000 feet (12,192 m).
Standard

Carry-On Portable Oxygen Concentrators

2012-06-06
CURRENT
AS8059
This SAE Aerospace Standard (AS) applies to a personal, portable oxygen concentrator (POC) to be supplied and used by a passenger requiring supplemental oxygen therapy while traveling on board civil, commercial, or personal aircraft. It covers a POC during both self-powered battery operation and while powered from an aircraft seat’s electrical power through the use of an accessory adapter. The POC is not intended to be connected to the aircraft’s oxygen systems or to be used by any aircraft personnel in any method of treatment or first aid of the general flying public.
Standard

Cleaning Methods and Procedures for Breathing Oxygen Equipment

1999-05-01
HISTORICAL
AS13591
The purpose of this document is to provide minimum requirements for cleaning aircraft breathing oxygen systems and components, inspection methods and packaging after cleaning, and guidelines for oxygen equipment cleaning areas.
Standard

Continuous Flow Chemical Oxygen Generators

1996-10-01
HISTORICAL
AS1304A
This SAE Aerospace Standard (AS) applies to performance and testing of solid chemical oxygen generators which produce oxygen at essentially ambient pressure for use aboard aircraft whose cabin pressure altitude does not exceed 40,000 ft (about 12,200 m). Portable chemical oxygen devices are covered by AS1303.
Standard

Continuous Flow Chemical Oxygen Generators

2014-06-24
CURRENT
AS1304B
This SAE Aerospace Standard (AS) applies to performance and testing of solid chemical oxygen generators which produce oxygen at essentially ambient pressure for use aboard aircraft whose cabin pressure altitude does not exceed 40,000 ft (about 12,200 m). Portable chemical oxygen devices are covered by AS1303.
Standard

Crew Member Oxygen Regulators, Demand

1995-02-01
CURRENT
AS8027
This SAE Aerospace Standard (AS) is intended to apply to those oxygen regulators which supply gaseous oxygen at breathing pressures to meet physiological requirements of aircraft flight crew members. It defines the minimum performance requirements and testing for aircraft demand type breathing oxygen regulators.
Standard

Crewmember Demand Oxygen Mask For Transport Category Aircraft

1996-07-01
HISTORICAL
AS8026A
This standard covers oxygen masks and breathing valves used with both panel mounted and mask mounted demand and pressure-demand oxygen regulators. Mask mounted oxygen regulators are covered under other standards, but when the mask mounted regulator incorporates an integral exhalation valve, the performance of this valve shall meet the requirements of this standard.
Standard

Crewmember Demand Oxygen Mask for Transport Category Aircraft

2019-08-14
CURRENT
AS8026B
This standard covers oxygen masks and breathing valves used with both panel mounted and mask mounted demand and pressure-demand oxygen regulators. Mask mounted oxygen regulators are covered under other standards, but when the mask mounted regulator incorporates an integral exhalation valve, the performance of this valve shall meet the requirements of this standard.
Standard

Guide for Evaluating Combustion Hazards in Aircraft Oxygen Systems

2003-01-11
CURRENT
AIR825/13
This guide is intended to promote safe designs, operations and maintenance on aircraft and ground support oxygen systems. This is also a summary of some work by the ASTM G 4 Committee related to oxygen fire investigations and design concerns to reduce the risk of an oxygen fire. There have been many recent technological advances and additional test data is available for evaluating and controlling combustion hazards in oxygen equipment. Standards that use this new information are rapidly evolving. A guide is needed to assist organizations and persons not completely familiar with this process to provide oxygen systems with minimum risks of combustion. This guide does not necessarily address all the detailed issues and provide all data that will be needed. For a complete analysis, supplemental publications need to be consulted. This guide does discuss the basics of oxygen systems fire hazards. The hazard analysis process is discussed and a simple example to explain this process.
Standard

MINIMUM STANDARD FOR OXYGEN PRESSURE REDUCERS

1973-05-01
HISTORICAL
AS1248
This standard is designed to cover all types of pressure reducers required for oxygen systems and for all performance profiles without regard for a particular inlet pressure or outlet pressure performance curve. Special attention will be given, however, to construction requirements essential in reducers where critical high initial oxygen pressures such as 1850 to 2250 psig (12.76 to 15.51 MN/m2 gauge) at 70° F (21.1° C) are involved.
Standard

MINIMUM STANDARDS FOR VALVE, HIGH PRESSURE OXYGEN, LINE SHUT OFF, MANUALLY OPERATED

1971-07-01
HISTORICAL
AS1214
This standard covers all types of manually operated high pressure oxygen line shut off valves utilizing either metallic or nonmetallic valve seats for use in general and commercial type aircraft. It is intended that the line valve should be installed in a position accessible in flight, when the cylinder mounted oxygen valves are not. The line shutoff valve may also be used optionally in large systems as a maintenance aid where only a portion of the system need be opened up and purged after repair or replacement of one or more parts.
Standard

Minimum General Standards for Oxygen Systems

2006-11-07
CURRENT
AS861B
This standard covers all types of oxygen breathing equipment used in non-military aircraft. It is intended that this standard supplement the requirements of the detail specification or drawings of specific components or assemblies, e.g., regulators, masks, cylinders, etc. Where a conflict exists between this and detail specifications, detail specifications shall take precedence.
Standard

Minimum General Standards for Oxygen Systems

2019-10-16
WIP
AS861C
This standard covers all types of oxygen breathing equipment used in non-military aircraft. It is intended that this standard supplement the requirements of the detail specification or drawings of specific components or assemblies, e.g., regulators, masks, cylinders, etc. Where a conflict exists between this and detail specifications, detail specifications shall take precedence.