Refine Your Search

Topic

Search Results

Standard

AEROSPACE INFORMATION REPORT FOR CONTINUOUS FLOW OXYGEN HOSE DISCONNECT FITTINGS

1991-09-01
HISTORICAL
AIR1358
This AIR indicates those dimensions, deemed critical by the manufacturer, which are required to be adhered to so that proper mating of the disconnect hose fitting with the correct disconnect be accomplished. The dimensions are critical, but not necessarily complete, in defining these fittings since there are other criteria which must also be met.
Standard

Aerospace Information Report for Continuous Flow Oxygen Hose Disconnect Fittings

2009-08-27
HISTORICAL
AIR1358B
This Aerospace Information Report (AIR) indicates those dimensions, deemed critical by the manufacturer to assure proper mating of disconnect hose fittings. The dimensions are critical, but not necessarily complete, in defining these fittings since there are other criteria which must also be met.
Standard

Aerospace Information Report for Continuous Flow Oxygen Hose Disconnect Fittings

2000-10-01
HISTORICAL
AIR1358A
This AIR indicates those dimensions, deemed critical by the manufacturer, which are required to be adhered to so that proper mating of the disconnect hose fitting with the correct disconnect be accomplished. The dimensions are critical, but not necessarily complete, in defining these fittings since there are other criteria which must also be met.
Standard

Aerospace Information Report for Continuous Flow Oxygen Hose Disconnect Fittings

2014-12-31
CURRENT
AIR1358C
This Aerospace Information Report (AIR) indicates those dimensions, deemed critical by the manufacturer to assure proper mating of disconnect hose fittings. The dimensions are critical, but not necessarily complete, in defining these fittings since there are other criteria which must also be met.
Standard

Aircraft Oxygen Replenishment Coupling for Civil Transport Aircraft (Design Standard)

2021-03-09
WIP
AS1219B
This SAE Aerospace Design Standard defines a coupling, which is installed in a high pressure (1850 to 2000 psig) oxygen system of a civil transport aircraft for the purpose of mating to ground oxygen replenishment facilities. Dimensions developed from AND10089, Detail Specification Sheet for Fitting End, Design Standard, For Cone Connection.
Standard

Aircraft Oxygen Replenishment Coupling for Civil Transport Aircraft (Design Standard)

2003-10-15
HISTORICAL
AS1219
This Aerospace Design Standard defines a coupling which is installed in an aircraft high pressure (1850 - 2000 psig) oxygen system of a civil transport aircraft for the purpose of mating with ground oxygen replenishment facilities. All dimensions above are reference only - See AND10089-3 for detail dimensions.
Standard

Aircraft Oxygen Replenishment Coupling for Civil Transport Aircraft (Design Standard)

2020-02-28
CURRENT
AS1219A
This SAE Aerospace Design Standard defines a coupling, which is installed in a high pressure (1850 to 2000 psig) oxygen system of a civil transport aircraft for the purpose of mating to ground oxygen replenishment facilities. Dimensions developed from AND10089, Detail Specification Sheet for Fitting End, Design Standard, For Cone Connection.
Standard

Basic Aircraft Oxygen Systems Design

2021-08-11
CURRENT
AIR825/14
This slash document collects general reference material related to gaseous oxygen system flow requirements and sizing calculations. This document will assist oxygen system equipment designers and operators to establish systems and equipment requirements. The document consists of charts, tables, system schematics, system requirements, and sample calculations for system sizing.
Standard

CONTINUOUS FLOW GENERAL AVIATION OXYGEN MASKS

1971-09-01
HISTORICAL
AS1224
This standard defines the minimum requirement for the design, construction and performance of continuous flow oxygen masks for crew and passengers of general aviation civil aircraft.
Standard

CREWMEMBER DEMAND OXYGEN MASK FOR TRANSPORT CATEGORY AIRCRAFT

1991-09-01
HISTORICAL
AS8026
This standard covers oxygen masks and breathing valves used with both panel mounted and mask mounted demand and pressure-demand oxygen regulators. Mask mounted oxygen regulators are covered under other standards, but when the mask mounted regulator incorporates an integral exhalation valve, the performance of this valve shall meet the requirements of this standard.
Standard

Carry-On Portable Oxygen Concentrators

2017-11-07
CURRENT
AS8059
This SAE Aerospace Standard (AS) applies to a personal, portable oxygen concentrator (POC) to be supplied and used by a passenger requiring supplemental oxygen therapy while traveling on board civil, commercial, or personal aircraft. It covers a POC during both self-powered battery operation and while powered from an aircraft seat’s electrical power through the use of an accessory adapter. The POC is not intended to be connected to the aircraft’s oxygen systems or to be used by any aircraft personnel in any method of treatment or first aid of the general flying public.
Standard

Chemical Oxygen Supplies

2012-10-08
HISTORICAL
AIR1133A
Solid chemical oxygen supplies of interest to aircraft operations are "chlorate candles" and potassium superoxide (KO2). Chlorate candles are used in passenger oxygen supply units and other emergency oxygen systems, such as submarines and escape devices. Potassium superoxide is not used in aircraft operations but is used in closed-cycle breathing apparatus. Characteristics and applications of both are discussed, with emphasis on chlorate candles.
X