Refine Your Search

Topic

Search Results

Standard

AEROSPACE - DYNAMIC TEST METHOD FOR DETERMINING THE RELATIVE DEGREE OF CLEANLINESS OF THE DOWNSTREAM SIDE OF FILTER ELEMENTS

1996-05-01
HISTORICAL
ARP599B
This SAE Aerospace Recommended Practice (ARP) describes a procedure for determining the insoluble contamination level of the downstream side of filter elements. Results of this procedure represent the particulate released from the tested filter element under the prevailing conditions of the test. The results may be used for comparative evaluation of the effectiveness of various cleaning methods or the cleanliness of elements after cleaning or as received from manufacturers.
Standard

AEROSPACE-PARTICLE COUNT DATA CONVERSION AND EXTRAPOLATION

1993-03-02
HISTORICAL
AIR877A
This Aerospace Information Report (AIR) describes a mathematical model that can be used to analyze particle count data. Particle counts that fit the model can be graphically displayed, converted from one counting size-frequency range to another, and extrapolated to estimate counts beyond the measured range. Derivation, applications and calculations are described.
Standard

Aerospace - Dynamic Test Method for Determining the Relative Degree of Cleanliness of the Downstream Side of Filter Elements

1996-05-01
HISTORICAL
ARP599
This test method describes a procedure for determining the insoluble contamination level of the downstream side of filter elements. Results of this procedure represent the particulate released from the tested filter element under the prevailing conditions of the test. The results may be used for comparative evaluation of the effectiveness of various cleaning methods or the cleanliness of elements after cleaning or as received from manufacturers. The data obtained by this procedure do not necessarily indicate, qualitatively or quantitatively, the contamination which may be released by a filter element into a fluid during service use. Because of the wide variety of conditions which may exist in service applications, it is recommended that the user design and conduct his own particular service performance test. (See paragraph 10.1).
Standard

Aerospace - Dynamic Test Method for Determining the Relative Degree of Cleanliness of the Downstream Side of Filter Elements

1992-07-01
HISTORICAL
ARP599A
This SAE Aerospace Recommended Practice (ARP) describes a procedure for determining the insoluble contamination level of the downsteam side of filter elements. Results of this procedure represent the particulate released from the tested filter element under the prevailing conditions of the test. The results may be used for comparative evaluation of the effectiveness of various cleaning methods or the cleanliness of elements after cleaning or as received from manufacturers.
Standard

Aerospace - Dynamic Test Method for Determining the Relative Degree of Cleanliness of the Downstream Side of Filter Elements

2008-06-22
CURRENT
ARP599D
This SAE Aerospace Recommended Practice (ARP) describes a procedure for determining the insoluble contamination level of the downstream side of filter elements. Results of this procedure represent the particulate released from the tested filter element under the prevailing conditions of the test. The results may be used for comparative evaluation of the effectiveness of various cleaning methods or the cleanliness of elements after cleaning or as received from manufacturers.
Standard

Aerospace - Dynamic Test Method for Determining the Relative Degree of Cleanliness of the Downstream Side of Filter Elements

2002-05-21
HISTORICAL
ARP599C
This SAE Aerospace Recommended Practice (ARP) describes a procedure for determining the insoluble contamination level of the downstream side of filter elements. Results of this procedure represent the particulate released from the tested filter element under the prevailing conditions of the test. The results may be used for comparative evaluation of the effectiveness of various cleaning methods or the cleanliness of elements after cleaning or as received from manufacturers.
Standard

Aerospace-Particle Count Data Conversion and Extrapolation

2012-09-24
CURRENT
AIR877C
This SAE Aerospace Information Report (AIR) describes a mathematical model that can be used to analyze particle count data. Particle counts that fit the model can be graphically displayed, converted from one counting size-frequency range to another, and extrapolated to estimate counts beyond the measured range. Derivation, applications, and calculations are described.
Standard

BUBBLE-POINT TEST METHOD

1968-03-01
HISTORICAL
ARP901
This test method describes a procedure for measuring the largest pore or hole in a filter or similar fluid-permeable porous structure. A standard referee test method for precise determination or resolution of disputes is specified. A simpler inspection test procedure for quality assurance "go-no-go" measurement is also given. Bubble-point testing physics, analysis of bubble-point test data, and correlation with other methods of pore size determination are separately discussed in the appendix.
Standard

Bubble-Point Test Method

2017-04-04
CURRENT
ARP901B
This test method describes a procedure for measuring the largest pore or hole in a filter or similar fluid-permeable porous structure. A standard referee test method for precise determination or resolution of disputes is specified. A simpler inspection test procedure for quality assurance “go-no-go” measurement is also given. Bubble-point testing physics, analysis of bubble-point test data, and correlation with other methods of pore size determination are separately discussed in the appendix.
Standard

Bubble-Point Test Method

2001-05-01
HISTORICAL
ARP901A
This test method describes a procedure for measuring the largest pore or hole in a filter or similar fluid-permeable porous structure. A standard referee test method for precise determination or resolution of disputes is specified. A simpler inspection test procedure for quality assurance “go-no-go” measurement is also given. Bubble-point testing physics, analysis of bubble-point test data, and correlation with other methods of pore size determination are separately discussed in the appendix.
Standard

FILTER-ELEMENT CLEANING METHODS

1965-10-15
HISTORICAL
AIR787
This Aerospace Information Report provides technical information to assist the development of specific cleaning methods for filter elements. Consideration is limited to filter elements which are designated as "cleanable" (not "disposable"), but which cannot be cleaned by simple and obvious procedures. Cleaning methods developed according to this report should be evaluated by the methods of ARP 725 and ARP 849. Satisfactory cleaning methods can be developed for most "cleanable" filter elements. Technical or economic feasibility of the cleaning method may be limited, however, by incompatibility of filter-element construction materials, by mechanical weakness or lack of corrosion resistance to withstand repeated or continued cleaning, or by the presence of unusually tenacious contamination. These factors must be considered when selecting approaches to the development of specific methods.
Standard

FINE WIRE MESH FOR FILTER ELEMENTS

1989-05-30
HISTORICAL
AIR888A
This AIR discusses the terminology, types, method of manufacture and chemistry of the fine wire meshes used for filtration of hydraulic, lubrication, fuel systems and similar applications. Information contained herein may be used for quality assurance testing to insure that a high performance filter grade wire mesh is acceptable for use in an aerospace application.
Standard

Filter Element Cleaning Methods

2019-07-15
WIP
AIR787B
This SAE Aerospace Information Report (AIR) provides technical information to assist the development of specific cleaning methods for filter elements. Consideration is limited to filter elements which are designated as "cleanable" (not "disposable"), but which cannot be cleaned by simple and obvious procedures. Cleaning methods developed according to this report should be evaluated by the methods of ARP725. Satisfactory cleaning methods can be developed for most "cleanable" filter elements. Technical or economic feasibility of the cleaning method may be limited, however, by incompatibility of filter-element construction materials, by mechanical weakness or lack of corrosion resistance to withstand repeated or continued cleaning, or by the presence of unusually tenacious contamination. These factors must be considered when selecting approaches to the development of specific methods.
Standard

Filter Element Cleaning Methods

2003-12-03
CURRENT
AIR787A
This SAE Aerospace Information Report (AIR) provides technical information to assist the development of specific cleaning methods for filter elements. Consideration is limited to filter elements which are designated as "cleanable" (not "disposable"), but which cannot be cleaned by simple and obvious procedures. Cleaning methods developed according to this report should be evaluated by the methods of ARP725. Satisfactory cleaning methods can be developed for most "cleanable" filter elements. Technical or economic feasibility of the cleaning method may be limited, however, by incompatibility of filter-element construction materials, by mechanical weakness or lack of corrosion resistance to withstand repeated or continued cleaning, or by the presence of unusually tenacious contamination. These factors must be considered when selecting approaches to the development of specific methods.
X