Refine Your Search

Topic

Search Results

Standard

AEROSPACE - DYNAMIC TEST METHOD FOR DETERMINING THE RELATIVE DEGREE OF CLEANLINESS OF THE DOWNSTREAM SIDE OF FILTER ELEMENTS

1996-05-01
HISTORICAL
ARP599B
This SAE Aerospace Recommended Practice (ARP) describes a procedure for determining the insoluble contamination level of the downstream side of filter elements. Results of this procedure represent the particulate released from the tested filter element under the prevailing conditions of the test. The results may be used for comparative evaluation of the effectiveness of various cleaning methods or the cleanliness of elements after cleaning or as received from manufacturers.
Standard

Aerospace - Dynamic Test Method for Determining the Relative Degree of Cleanliness of the Downstream Side of Filter Elements

2008-06-22
CURRENT
ARP599D
This SAE Aerospace Recommended Practice (ARP) describes a procedure for determining the insoluble contamination level of the downstream side of filter elements. Results of this procedure represent the particulate released from the tested filter element under the prevailing conditions of the test. The results may be used for comparative evaluation of the effectiveness of various cleaning methods or the cleanliness of elements after cleaning or as received from manufacturers.
Standard

Aerospace - Dynamic Test Method for Determining the Relative Degree of Cleanliness of the Downstream Side of Filter Elements

2002-05-21
HISTORICAL
ARP599C
This SAE Aerospace Recommended Practice (ARP) describes a procedure for determining the insoluble contamination level of the downstream side of filter elements. Results of this procedure represent the particulate released from the tested filter element under the prevailing conditions of the test. The results may be used for comparative evaluation of the effectiveness of various cleaning methods or the cleanliness of elements after cleaning or as received from manufacturers.
Standard

Aerospace - Evaluation of Particulate Contamination in Hydraulic Fluid - Membrane Procedure

2018-08-13
CURRENT
ARP4285A
This SAE Aerospace Recommended Practice (ARP) establishes a method for evaluating the particulate matter extracted from the working fluid of a hydraulic system or component using a membrane. The amount of particulate matter deposited on the membrane due to filtering a given quantity of fluid is visually compared against a standard membrane in order to provide an indication of the cleanliness level of the fluid.
Standard

Aerospace - Evaluation of Particulate Contamination in Hydraulic Fluid - Membrane Procedure

2001-03-01
HISTORICAL
ARP4285
This SAE Aerospace Recommended Practice (ARP) establishes a method for evaluating the particulate matter extracted from the working fluid of a hydraulic system or component using a membrane. The amount of particulate matter deposited on the membrane due to filtering a given quantity of fluid is visually compared against a standard membrane in order to provide an indication of the cleanliness level of the fluid. A particular feature of this method is the membrane preparation to achieve an even particulate distribution on the membrane suitable for other applications. Membrane evaluation using standard membranes, described in this document, is an alternative technique to counting with either an optical microscope (ARP598) or an automatic particle counter (ISO 11500). The latter particle counting procedures are considered more precise.
Standard

BUBBLE-POINT TEST METHOD

1968-03-01
HISTORICAL
ARP901
This test method describes a procedure for measuring the largest pore or hole in a filter or similar fluid-permeable porous structure. A standard referee test method for precise determination or resolution of disputes is specified. A simpler inspection test procedure for quality assurance "go-no-go" measurement is also given. Bubble-point testing physics, analysis of bubble-point test data, and correlation with other methods of pore size determination are separately discussed in the appendix.
Standard

Bubble-Point Test Method

2001-05-01
HISTORICAL
ARP901A
This test method describes a procedure for measuring the largest pore or hole in a filter or similar fluid-permeable porous structure. A standard referee test method for precise determination or resolution of disputes is specified. A simpler inspection test procedure for quality assurance “go-no-go” measurement is also given. Bubble-point testing physics, analysis of bubble-point test data, and correlation with other methods of pore size determination are separately discussed in the appendix.
Standard

Bubble-Point Test Method

2017-04-04
CURRENT
ARP901B
This test method describes a procedure for measuring the largest pore or hole in a filter or similar fluid-permeable porous structure. A standard referee test method for precise determination or resolution of disputes is specified. A simpler inspection test procedure for quality assurance “go-no-go” measurement is also given. Bubble-point testing physics, analysis of bubble-point test data, and correlation with other methods of pore size determination are separately discussed in the appendix.
Standard

Evaluating Effectiveness of Filter Element Cleaning Methods

2014-06-03
CURRENT
ARP725B
This SAE Aerospace Recommended Practice (ARP) presents a procedure for evaluating cleaning methods with respect to contaminant removal and element degradation particularly for metallic filter elements. A procedure for checking durability of cleaning equipment and a referee cleaning method are also included. It is applicable only to the evaluation of cleaning methods proposed for removal of service dirt and not for built-in dirt, liquid oxygen (LOX) cleaning, etc. Supporting information for use with the ARP is also included.
Standard

Evaluating Effectiveness of Filter Element Cleaning Methods

2003-06-05
HISTORICAL
ARP725A
This SAE Aerospace Recommended Practice (ARP) presents a procedure for evaluating cleaning methods with respect to contaminant removal and element degradation particularly for metallic filter elements. A procedure for checking durability of cleaning equipment and a referee cleaning method are also included. It is applicable only to the evaluation of cleaning methods proposed for removal of service dirt and not for built-in dirt, liquid oxygen (LOX) cleaning, etc. Supporting information for use with the ARP is also included.
Standard

FINE WIRE MESH FOR FILTER ELEMENTS

1989-05-30
HISTORICAL
AIR888A
This AIR discusses the terminology, types, method of manufacture and chemistry of the fine wire meshes used for filtration of hydraulic, lubrication, fuel systems and similar applications. Information contained herein may be used for quality assurance testing to insure that a high performance filter grade wire mesh is acceptable for use in an aerospace application.
Standard

Fine Wire Mesh for Filter Elements

1997-06-01
HISTORICAL
AIR888B
This SAE Aerospace Information Report (AIR) discusses the terminology, types, method of manufacture and chemistry of the fine wire meshes used for filtration of hydraulic, lubrication fuel systems, and similar applications. Information contained herein may be used for quality assurance testing to insure that a high performance filter grade wire mesh is acceptable for use in an aerospace application.
Standard

Fine Wire Mesh for Filter Elements

2012-09-24
CURRENT
AIR888C
This SAE Aerospace Information Report (AIR) discusses the terminology, types, method of manufacture and chemistry of the fine wire meshes used for filtration of hydraulic, lubrication fuel systems, and similar applications. Information contained herein may be used for quality assurance testing to insure that a high performance filter grade wire mesh is acceptable for use in an aerospace application.
Standard

LIQUID FILTER RATINGS, PARAMETERS AND TESTS

1993-02-03
HISTORICAL
AIR887B
This SAE Aerospace Information Report (AIR) identifies and explains the meaning of various ratings and terms used to describe the physical characteristics of liquid filter elements. The significance of various filter parameters is discussed. In addition, a number of filter test methods is briefly described. This AIR and the data presented are only applicable to filters in which the system liquid wets the filter elements. This document includes equivalent metric units (in parentheses) as referenced information.
Standard

LIQUID FILTER RATINGS, PARAMETERS AND TESTS

1991-10-01
HISTORICAL
AIR887A
This AIR identifies and explains the meaning of various ratings and terms used to describe the physical characteristics of liquid filter elements. The significance of various filter parameters are discussed. In addition, a number of filter test methods are briefly described. This AIR and the data presented are only applicable to filters in which the system liquid wets the filter elements.
X