ARC Fault Circuit Breaker ( AFCB), Aircraft, Trip-Free Single Phase and Three Phase 115 VAC, 400 Hz - Constant Frequency

2023-03-27
CURRENT
AS5692A
The primary function of this specification is to cover the general requirements for manual reset trip-free arc fault/thermal circuit breakers for use in aircraft electrical systems conforming to MIL-STD-704. As a secondary function, this specification may possibly cover the general requirements for AFCBs for use in primary vehicles, other than aircraft, when mounted directly to the structure.
Standard

ARC Fault Circuit Breaker (AFCB), Aircraft, Trip-Free 28 VDC

2023-03-27
CURRENT
AS6019
The primary function of this specification is to cover the general requirements for 28 VDC manual reset trip-free arc fault/thermal circuit breakers for use in aircraft electrical systems conforming to MIL-STD-704. As a secondary function, this specification may possibly cover the general requirements for AFCBs for use in primary vehicles, other than aircraft, when mounted directly to the structure.
Standard

Electromechanical Power Controller/Relay, General Specification For

2010-01-06
HISTORICAL
AS5363
This specification establishes general requirements for a family of trip-free Electromechanical Power Controller/Relays (EMPC) with electronic overcurrent sensing and control, intended for use in electrical systems conforming to RTCA, D0160 Revision C. These devices will be utilized for the protection of ac and/or dc electrical systems, bus feeders, and electrical equipment.
Standard

Electromechanical Power Controller/Relay, General Specification For

2016-01-08
CURRENT
AS5363A
This specification establishes general requirements for a family of trip-free Electromechanical Power Controller/Relays (EMPC) with electronic overcurrent sensing and control, intended for use in electrical systems conforming to RTCA, D0160 Revision C. These devices will be utilized for the protection of ac and/or dc electrical systems, bus feeders, and electrical equipment.
Standard

Fuse, Current Limiter Type, Aircraft

1997-12-01
HISTORICAL
AS5372
This specification covers the requirements for current limiter type fuses for use in aircraft primary electrical power systems conforming to MIL-STD-704. These limiters are suitable for use in MIL-F-5373 fuse holders for operation at −54°C to 125°C.
Standard

SELECTION, APPLICATION, and INSPECTION of ELECTRIC OVERCURRENT PROTECTIVE DEVICES

1972-08-01
HISTORICAL
ARP1199
This Aerospace Recommended Practice provides technical and application information needed by the designers of aircraft electric systems and support equipment for the selection of overcurrent protective devices. It provides definitions to permit comparisons of various electric circuit protective devices. Included also are recommended procedures for periodic inspection.