Application Testing of Oil-to-Water Oil Coolers for Heat Transfer Performance

2005-06-21
HISTORICAL
J2414_200506
This SAE Recommended Practice is applicable to oil-to-water oil coolers installed on mobile or stationary equipment. Such oil coolers may be used for the purpose of cooling automatic transmission fluid, hydraulic system oil, retarder system fluid, etc. This document outlines the methods of procuring the test data to determine the operating characteristics of the oil cooling system and the interpretation of the results. For information regarding application testing of oil-to-air oil coolers for heat transfer performance, see SAE J1468.
Standard

Application Testing of Oil-to-Water Oil Coolers for Heat Transfer Performance

1999-03-01
HISTORICAL
J2414_199903
This SAE Recommended Practice is applicable to oil-to-water oil coolers installed on mobile or stationary equipment. Such oil coolers may be used for the purpose of cooling automatic transmission fluid, hydraulic system oil, retarder system fluid, etc. This document outlines the methods of procuring the test data to determine the operating characteristics of the oil cooling system and the interpretation of the results. For information regarding application testing of oil-to-air oil coolers for heat transfer performance, see SAE J1468.
Standard

COOLANT CONCENTRATE (LOW SILICATE, ETHYLENE GLYCOL TYPE REQUIRING AN INITIAL CHARGE OF SUPPLEMENTAL COOLANT ADDITIVE) FOR HEAVY-DUTY ENGINES

1990-04-01
HISTORICAL
J1941_199004
This SAE Recommended Practice applies to engine coolant concentrate, low silicate ethylene glycol base, for use in cooling systems of heavy-duty engines. An initial charge of supplemental coolant additive (SCA) is required when using this type of coolant concentrate. This document applies to engine coolant concentrates for heavy-duty engine requirements. SAE J1034 applies to coolant concentrates for automobile and light truck applications. For further information on engine coolants, see SAE J814.
Standard

Cooling System Metallic Caps and Filler Necks

2020-01-29
CURRENT
J164_202001
This SAE Recommended Practice was developed primarily for passenger car and truck application, but may be used in marine, industrial, and similar applications.
Standard

ENGINE COOLING FAN STRUCTURAL ANALYSIS

1982-04-01
HISTORICAL
J1390_198204
It is necessary to identify and attempt to evaluate the characteristics of an application which can have an effect on fan durability. Failures almost always occur in fatigue, so careful attention should be paid to avoid resonance or forced vibration of the fan. This section considers vibrational inputs, fan natural frequencies, and operating speed as part of the initial structural integrity analysis. A fan application fact sheet (Table 1) is recommended as a form to communicate between user and fan supplier.
Standard

ENGINE COOLING FAN STRUCTURAL ANALYSIS

1996-06-01
HISTORICAL
J1390_199606
Three levels of fan structural analysis are included in this practice: 1 Initial Structural Integrity 2 In-vehicle Testing 3 Durability Test Methods The Initial Structural Integrity section describes analytical and test methods used to predict potential resonance and, therefore, possible fatigue accumulation. The In-vehicle (or machine) section enumerates the general procedure used to conduct a fan strain gage test. Various considerations that may affect the outcome of strain gage data have been described for the user of this procedure to adapt/discard depending on the particular application. The Durability Test Methods section describes the detailed test procedures that may be used depending on type of fan, equipment availability, and end objective. Each of the previous levels builds upon information derived from the previous level. Engineering judgment is required as to the applicability of each level to a different vehicle environment or a new fan design.
Standard

Electric Drive Cooling Fan Motor Mounting

2010-07-08
HISTORICAL
J2873_201007
This SAE Recommended Practice is applicable to Electric Drive Cooling Fan Assemblies used in Light Duty vehicle cooling systems (typically, passenger cars and light duty trucks). This document outlines the Electric Drive Cooling Fan Motor Mounting interface characteristics such that a common standard is possible.
Standard

Electric Drive Cooling Fan Motor Mounting

2016-03-11
CURRENT
J2873_201603
This SAE Recommended Practice is applicable to Electric Drive Cooling Fan Assemblies used in Light Duty vehicle cooling systems (typically, passenger cars and light duty trucks). This document outlines the Electric Drive Cooling Fan Motor Mounting interface characteristics such that a common standard is possible.
Standard

Engine Cooling Fan Structural Analysis

2003-04-24
HISTORICAL
J1390_200304
Three levels of fan structural analysis are included in this practice: 1 Initial Structural Integrity 2 In-vehicle Testing 3 Durability Test Methods The Initial Structural Integrity section describes analytical and test methods used to predict potential resonance and, therefore, possible fatigue accumulation. The In-vehicle (or machine) section enumerates the general procedure used to conduct a fan strain gage test. Various considerations that may affect the outcome of strain gage data have been described for the user of this procedure to adapt/discard depending on the particular application. The Durability Test Methods section describes the detailed test procedures that may be used depending on type of fan, equipment availability, and end objective. Each of the previous levels builds upon information derived from the previous level. Engineering judgment is required as to the applicability of each level to a different vehicle environment or a new fan design.
Standard

Engine Cooling Fan Structural Analysis

2012-01-09
HISTORICAL
J1390_201201
Three levels of fan structural analysis are included in this practice: 1 Initial Structural Integrity 2 In-vehicle Testing 3 Durability Test Methods The Initial Structural Integrity section describes analytical and test methods used to predict potential resonance and, therefore, possible fatigue accumulation. The In-vehicle (or machine) section enumerates the general procedure used to conduct a fan strain gage test. Various considerations that may affect the outcome of strain gage data have been described for the user of this procedure to adapt/discard depending on the particular application. The Durability Test Methods section describes the detailed test procedures that may be used depending on type of fan, equipment availability, and end objective. Each of the previous levels builds upon information derived from the previous level. Engineering judgment is required as to the applicability of each level to a different vehicle environment or a new fan design.
Standard

Engine Cooling Fan Structural Analysis

2017-06-01
HISTORICAL
J1390_201706
Three levels of fan structural analysis are included in this practice: a Initial Structural Integrity b In-vehicle Testing c Durability (Laboratory) Test Methods The Initial Structural Integrity section describes analytical and test methods used to predict potential resonance and, therefore, possible fatigue accumulation. The In-vehicle (or machine) section enumerates the general procedure used to conduct a fan strain gage test. Various considerations that may affect the outcome of strain gage data have been described for the user of this procedure to adapt/discard depending on the particular application. The Durability Test Methods section describes the detailed test procedures for a laboratory environment that may be used depending on type of fan, equipment availability, and end objective. The second and third levels build upon information derived from the previous level.
Standard

Engine Cooling Fan Structural Analysis

2022-02-23
CURRENT
J1390_202202
Three levels of fan structural analysis are included in this practice: a Initial structural integrity. b In-vehicle testing. c Durability (laboratory) test methods. The initial structural integrity section describes analytical and test methods used to predict potential resonance and, therefore, possible fatigue accumulation. The in-vehicle (or machine) section enumerates the general procedure used to conduct a fan strain gage test. Various considerations that may affect the outcome of strain gage data have been described for the user of this procedure to adapt/discard depending on the particular application. The durability test methods section describes the detailed test procedures for a laboratory environment that may be used depending on type of fan, equipment availability, and end objective. The second and third levels build upon information derived from the previous level.
Standard

FAN HUB BOLT CIRCLES AND PILOT HOLES

1984-07-01
HISTORICAL
J635_198407
The scope of the specification is limited to heavy-duty diesel engine manufacturers, fan suppliers, and end users. Standard mounting patterns are given for fans up to 2000 mm rotating diameter. Passenger car and light-duty fans were not addressed because committee members issuing the specification felt that standards for these fans could be better addressed by personnel working in the market segments which use those fans. Rationale for issuance of the specification is cost savings through reduction of part numbers and inventory. Failure to comply with this specification will result in the need to release and carry in inventory parts of identical blade geometry and construction, but with different mounting patterns.
Standard

FAN HUB BOLT CIRCLES AND PILOT HOLES

1995-06-28
HISTORICAL
J635_199506
The purpose of this SAE Recommended Practice is to encourage the standardization of mounting patterns for engine cooling fans as new engines are designed and developed in SI metric units. It is specifically not the objective of the specification to address the soft metric conversion of existing mounting patterns on engines designed in English units. The scope of the specification is limited to heavy-duty diesel engine manufacturers, fan suppliers, and end users. Standard mounting patterns are given for fans up to 2000 mm rotating diameter. Passenger car and light-duty fans were not addressed because committee members issuing the specification felt that standards for these fans could be better addressed by personnel working in the market segments which use those fans. See Figure 1 and Table 1. Rationale for issuance of the specification is cost savings through reduction of part numbers and inventory.
Standard

Fan Hub Bolt Circles and Pilot Holes

2014-03-12
HISTORICAL
J635_201403
This Recommended Practice applies to engine cooling fans up to 2000 mm in diameter with a mounting interface consisting of a pilot hole and a circular bolt pattern. Most of these fans are belt, gear, clutch, hydraulically, or electrically driven.
Standard

Fan Hub Bolt Circles and Pilot Holes

2018-06-02
CURRENT
J635_201806
This Recommended Practice applies to engine cooling fans up to 2000 mm in diameter with a mounting interface consisting of a pilot hole and a circular bolt pattern. Most of these fans are belt, gear, clutch, hydraulically, or electrically driven.