Refine Your Search

Topic

Search Results

Standard

APPLICATION TESTING OF OIL TO AIR OIL COOLERS FOR COOLING PERFORMANCE

1985-11-01
HISTORICAL
J1468_198511
This Recommended Practice is applicable to oil to air oil coolers installed on mobile or stationary equipment. This document outlines the method of procuring the test data to determine operating characteristics of the oil cooling system and the interpretation of the test results.
Standard

APPLICATION TESTING OF OIL-TO-AIR OIL COOLERS FOR COOLING PERFORMANCE

1993-05-20
HISTORICAL
J1468_199305
This SAE Recommended Practice is applicable to oil-to-air oil coolers installed on mobile or stationary equipment. This document outlines the method of procuring the test data to determine operating characteristics of the oil cooling system and the interpretation of the test results.
Standard

Application Testing of Oil-to-Water Oil Coolers for Heat Transfer Performance

2005-06-21
HISTORICAL
J2414_200506
This SAE Recommended Practice is applicable to oil-to-water oil coolers installed on mobile or stationary equipment. Such oil coolers may be used for the purpose of cooling automatic transmission fluid, hydraulic system oil, retarder system fluid, etc. This document outlines the methods of procuring the test data to determine the operating characteristics of the oil cooling system and the interpretation of the results. For information regarding application testing of oil-to-air oil coolers for heat transfer performance, see SAE J1468.
Standard

Application Testing of Oil-to-Water Oil Coolers for Heat Transfer Performance

2010-10-15
CURRENT
J2414_201010
This SAE Recommended Practice is applicable to oil-to-water oil coolers installed on mobile or stationary equipment. Such oil coolers may be used for the purpose of cooling automatic transmission fluid, hydraulic system oil, retarder system fluids, etc. This document outlines the methods of procuring the test data to determine the operating characteristics of the oil cooling system and the interpretation of the results. For information regarding application testing of oil-to-air oil coolers for heat transfer performance, see SAE J1468. The purpose of this document is to provide a procedure for determining the heat transfer performance characteristics of an oil- to-water oil cooler under specified application operation conditions.
Standard

Application Testing of Oil-to-Water Oil Coolers for Heat Transfer Performance

1999-03-01
HISTORICAL
J2414_199903
This SAE Recommended Practice is applicable to oil-to-water oil coolers installed on mobile or stationary equipment. Such oil coolers may be used for the purpose of cooling automatic transmission fluid, hydraulic system oil, retarder system fluid, etc. This document outlines the methods of procuring the test data to determine the operating characteristics of the oil cooling system and the interpretation of the results. For information regarding application testing of oil-to-air oil coolers for heat transfer performance, see SAE J1468.
Standard

Charge Air Cooler Internal Cleanliness, Leakage, and Nomenclature

2019-09-05
CURRENT
J1726_201909
This SAE Recommended Practice provides test methods and criteria for evaluating the internal cleanliness and air leakage for engine charge air coolers. This SAE Recommended Practice also provides nomenclature and terminology in common use for engine charge air coolers, related charge air cooling system components, and charge air cooling system operational performance parameters.
Standard

Charge Air Cooler Internal Cleanliness, Leakage, and Nomenclature

2015-07-01
HISTORICAL
J1726_201507
This SAE Recommended Practice provides test methods and criteria for evaluating the internal cleanliness and air leakage for engine charge air coolers. This SAE Recommended Practice also provides nomenclature and terminology in common use for engine charge air coolers, related charge air cooling system components, and charge air cooling system operational performance parameters.
Standard

ENGINE COOLANT CONCENTRATE—ETHYLENE-GLYCOL TYPE

1973-06-01
HISTORICAL
J1034_197306
This standard covers glycol-type compounds which, when added to engine cooling systems at concentrations of 40-70% by volume of coolant concentrate in water, provide corrosion protection, lower the freezing point, and raise the boiling point of the coolant. Such compounds are intended for a minimum of 1 year (approximately 12,000 miles) service in a properly maintained cooling system. (Reference: SAE HS-40, Maintenance of Automotive Engine Cooling Systems.) Coolants meeting this standard do not require the use of supplementary materials. For additional information on engine coolants, see SAE J814.
Standard

Heavy Duty Vehicle Cooling Test Code

2012-09-17
HISTORICAL
J1393_201209
This document supersedes SAE J819 - Engine Cooling System Field Test. The purpose of this SAE Recommended Practice is to establish a testing procedure to determine the performance capability of engine cooling systems, including charge air coolers, on heavy-duty vehicles with liquid-cooled internal combustion engines. The definition of heavy vehicles for this document includes, but is not limited to, on- and off-highway trucks, cranes, drill rigs, construction, forestry and agricultural machines. Vehicles equipped with side or rear-mounted radiators may require an alternate procedure of a towing dynamometer because of peculiar aerodynamics. Testing is generally conducted to determine compliance with cooling criteria established by the engine manufacturer or the end product user to meet a desired engine reliability goal.
Standard

Heavy-Duty Nonmetallic Engine Cooling Fans--Material, Manufacturing, and Test Considerations

2012-02-06
CURRENT
J1474_201202
The following topics are included in this report: Section 2 - References Section 3-Definitions Section 4 - Material Selection Section 5 - Production Considerations Section 6 - Initial Structural Integrity Section 7 - In-Vehicle Testing Section 8 - Laboratory Testing The Material Selection section lists environmental factors and material properties which should be considered when determining appropriate fan material(s) for a given application. The Production Considerations section covers various aspects of machine selection, mold design, and process control. The Initial Structural Integrity section lists factors which should be considered in addition to those covered by Section 3 of SAE J1390. The In-Vehicle Testing section lists factors which should be considered in addition to those covered by Section 4 of SAE J1390.
Standard

Heavy-Duty Vehicle Cooling Test Procedures

2023-02-06
CURRENT
J1393_202302
The purpose of this SAE Recommended Practice is to establish a testing procedure to determine the performance capability of heavy-duty vehicle cooling systems to meet Original Equipment Manufacturer or end user thermal specifications to ensure long term reliable vehicle operations. The recommendations from the present document are intended for heavy-duty vehicles including, but not limited to, on- and off-highway trucks, buses, cranes, drill rigs, construction, forestry, and agricultural machines.