Technical Paper

Design Evolution of the Capillary Pumped Loop (CAPL 2) Flight Experiment

1996-07-01
961431
The Capillary Pumped Loop Flight Experiment (CAPL 2) employs a passive two-phase thermal control system that uses the latent heat of vaporization of ammonia to transfer heat over long distances. CAPL was designed as a prototype of the Earth Observing System (EOS) instrument thermal control systems. The purpose of the mission was to provide validation of the system performance in microgravity, prior to implementation on EOS. CAPL 1 was flown on STS-60 in February, 1994, with some unexpected results related to gravitational effects on two-phase systems. Start-up difficulties on CAPL 1 led to a redesign of the experiment (CAPL 2) and a reflight on STS-69 in September of 1995. The CAPL 2 flight was extremely successful and the new “starter pump” design is now baselined for the EOS application. This paper emphasizes the design history, the CAPL 2 design, and lessons learned from the CAPL program.
Technical Paper

Flight Testing of a Cryogenic Capillary Pumped Loop

1999-08-02
1999-01-2627
This paper describes the flight test results of the fifth generation cryogenic capillary pumped loop (CCPL-5) which flew on the Space Shuttle STS-95 in October of 1998 as part of the CRYOTSU Flight Experiment. This flight was the first in-space demonstration of the CCPL, a lightweight heat transport and thermal switching device for future integrated cryogenic bus systems. The CCPL-5 utilized nitrogen as the working fluid and operated between 75K and 110K. Flight results indicated excellent performance of the CCPL-5 in a micro-gravity environment. The CCPL could start from a supercritical condition in all tests, and the reservoir set point temperature controlled the loop operating temperature regardless of changes in the heat load and/or the sink temperature. In addition, the loop demonstrated successful operation with heat loads ranging from 0.5W to 3W, as well as with parasitic heat loads alone.
Technical Paper

Flow Visualization within a Capillary Evaporator

1993-07-01
932236
A Capillary Pumped Loop (CPL) is an advanced two-phase heat transport device which utilizes capillary forces developed within porous wicks to move a working fluid. The advantage this system has over conventional thermal management systems is its ability to transfer large heat loads over long distances at a controlled temperature. Extensive ground testing and two flight experiments have been performed over the past decade which have demonstrated the potential of the CPL as a reliable and versatile thermal control system for space applications. While the performance of CPL's as “black boxes” is now well understood, the internal thermo-fluid dynamics in a CPL are poorly known due to the difficulty of taking internal measurements. In order to visualize transient thermohydraulic processes occurring inside an evaporator, a see-through capillary evaporator was built and tested at NASA's Goddard Space Flight Center.
Technical Paper

Ground Tests of Capillary Pumped Loop (CAPL 3) Flight Experiment

1998-07-13
981812
The success of CAPL 2 flight experiment has stirred many interests in using capillary pumped loop (CPL) devices for spacecraft thermal control. With only one evaporator in the loop, CAPL 2 was considered a point design for the Earth Observing System (EOS-AM). To realize the full benefits of CPLs, a reliable system with multiple evaporators must be developed and successfully demonstrated in space. The Capillary Pumped Loop (CAPL 3) Flight Experiment was designed to flight demonstrate a multiple evaporator CPL in a space environment. New hardware and concepts were developed for CAPL 3 to enable reliable start-up, constant conductance operation, and heat load sharing. A rigorous ground test program was developed and extensive characterization tests were conducted. All performance requirements were met, and the loop demonstrated very reliable operation.
Technical Paper

Loop Heat Pipe Operating Temperature Dependence on Liquid Line Return Temperature

2004-07-19
2004-01-2506
A Loop Heat Pipe (LHP) is a passive two-phase heat transfer device developed and successfully employed to cool spacecraft (satellite) electronics. The intrinsic benefits of this technology (lightweight, small volume, high thermal conductance) make it an attractive potential solution to many problems in ground vehicle thermal management. As most published LHP research has focused on cooling orbiting spacecraft components, there is little knowledge of how LHPs perform under the temperature extremes (−40°C to 40°C) and diurnal/seasonal fluctuations anticipated with terrestrial applications. Ambient temperature extremes mandate consideration of transport line heat exchange with the surroundings (parasitic losses/gains). This paper presents results from an experimental investigation of liquid line return temperature impact on system performance for sink temperatures from −30°C to 40°C and evaporator loads up to 700 Watts.
Technical Paper

Mathematical Modeling of Multiple Evaporator / Multiple Condenser Loop Heat Pipes and Test Data Verification

2007-07-09
2007-01-3235
Loop Heat Pipes have proven as reliable heat transports for spacecraft thermal control systems. NASA Goddard Space Flight Center in collaboration with NASA Jet Propulsion Laboratory recently proposed a miniature dual pump/condenser LHP system for use in future Mars missions. Results of a ground test program indicated that the dual pump/condenser LHP performed very well, but in a complicated manner. No analytical model was available to facilitate the design/analysis of this emerging technology. A generalized LHP theory will be presented in this paper along with the derived governing equations and solution scheme. Model predictions were made and compared with test data for validation.
Technical Paper

Operating Characteristics of Loop Heat Pipes

1999-07-12
1999-01-2007
The loop heat pipe (LHP) was invented in Russia in the early 1980’s. It is a two-phase heat transfer device that utilizes the evaporation and condensation of a working fluid to transfer heat, and the capillary forces developed in fine porous wicks to circulate the fluid. The LHP is known for its high pumping capability and robust operation because it uses fine-pored metal wicks and the integral evaporator/hydro-accumulator design. It has gained rapid acceptance in recent years as a thermal control device in space applications. This paper presents an overview of the LHP operation. The physical processes and the thermal-hydraulic behaviors of the LHP are first described. Operating characteristics as functions of various parameters including the heat load, sink temperature, ambient temperature, and elevation are presented. Peculiar behaviors in LHP operation such as temperature hysteresis and temperature overshoot during start-up are explained.
Technical Paper

Start-Up Behaviors in the CAPL 2 Flight Experiment

1997-07-01
972328
The CAPL 2 Flight Experiment, flown on Space Shuttle STS-69 in 1995, was a flight demonstration of a full-scale prototype of a thermal control system planned for the Earth Observing System (EOS-AM) instruments Flight tests successfully demonstrated various CPL operations with simulated EOS-AM power profiles, including baseline and backup start-up procedures. In general, there were no significant differences in CPL performance between one-G and zero-G. However, some unusual behaviors were observed in several start-ups during the flight test. This paper describes CAPL 2 start-ups in detail, and offers explanations for the notably different zero-G behaviors.
Technical Paper

Testing of A Loop Heat Pipe Subjected to Variable Accelerating Forces, Part 1: Start-up

2000-07-10
2000-01-2488
Loop Heat Pipes (LHPs) are being considered for cooling of military combat vehicles and spinning spacecraft. In these applications, it is important to understand the effect of an accelerating force on the performance of LHPs. In order to investigate such an effect, a miniature LHP was installed on a spin table and subjected to variable accelerating forces by spinning the table at different angular speeds. Several patterns of accelerating forces were applied, i.e. continuous spin at different speeds and periodic spin at different speeds and frequencies. The resulting centrifugal accelerations ranged from 1.2 g's to 4.8 g's. This paper presents the first part of the experimental study, i.e. the effects of an accelerating force on the LHP start-up. Tests were conducted by varying the heat load to the evaporator, condenser sink temperature, and LHP orientation relative to the direction of the accelerating force.
Technical Paper

Testing of A Loop Heat Pipe Subjected to Variable Accelerating Forces, Part 2: Temperature Stability

2000-07-10
2000-01-2489
Loop Heat Pipes (LHPs) are being considered for cooling of military combat vehicles and spinning spacecraft. In these applications, it is important to understand the effect of an accelerating force on the performance of LHPs. In order to investigate such an effect, a miniature LHP was installed on a spin table and subjected to variable accelerating forces by spinning the table at different angular speeds. Several patterns of accelerating forces were applied, i.e. continuous spin at different speeds and periodic spin at different speeds and frequencies. The resulting centrifugal accelerations ranged from 1.2 g's to 4.8 g's. This paper presents the second part of the experimental study, i.e. the effect of an accelerating force on the LHP operating temperature. It has been known that the LHP operating temperature under a stationary condition is a function of the evaporator power and the condenser sink temperature when the compensation temperature is not actively controlled.
Technical Paper

Testing of Flight Components for the Capillary Pumped Loop Flight Experiment

1993-07-01
932235
The Capillary Pumped Loop Flight Experiment (CAPL) is a prototype of the Earth Observing System (EOS) instrument thermal control systems. Four CAPL flight hardware components were tested in the Instrument Thermal Test Bed at NASA's Goddard Space Flight Center. The components tested were the capillary cold plates, capillary starter pump, heat pipe heat exchangers (HPHXs), and reservoir. The testing verified that all components meet or exceed their individual performance specifications. Consequently, the components have been integrated into the CAPL experiment which will be flown on the Space Shuttle in late 1993.
Technical Paper

Testing of a Loop Heat Pipe with Two Evaporators and Two Condensers

2001-07-09
2001-01-2190
Most existing loop heat pipes (LHPs) consist of one single evaporator and one single condenser. LHPs with multiple evaporators are very desirable for cooling multiple heat sources or a heat source with large thermal footprints. Extending the current LHP technology to include multiple evaporators and multiple condensers faces some challenges, including operating temperature stability, adaptability of loop operation to rapid power and sink temperature transients, and sizing of the compensation chambers (CCs). This paper describes an overview of an extensive testing program for an LHP with two evaporators and two condensers. Tests performed include start-up, power cycle, sink temperature cycle, CC temperature cycle, and capillary limit. Test results showed that the loop could be started successfully in most cases, and the operating temperature was a function of the total heat load, heat load distribution between the two evaporators, condenser sink temperature and ambient temperature.
Technical Paper

Thermal Performance of Capillary Pumped Loops Onboard Terra Spacecraft

2004-07-19
2004-01-2504
The Terra spacecraft is the flagship of NASA’s Earth Science Enterprise. It provides global data on the atmosphere, land, and oceans, as well as their interactions with solar radiation and one another. Three Terra instruments utilize Capillary Pumped Heat Transport Systems (CPHTS) for temperature control. Each CPHTS, consisting of two capillary pumped loops (CPLs) and several heat pipes and electrical heaters, is designed for instrument heat loads ranging from 25W to 264W. The working fluid is ammonia. Since the launch of the Terra spacecraft in December 1999, each CPHTS has been providing a stable interface temperature specified by the instrument under all modes of spacecraft and instrument operations. The ability to change the CPHTS operating temperature upon demand while in service has also extended the useful life of one instrument. This paper describes the design and on-orbit performance of the CPHTS thermal systems.