Refine Your Search

Topic

Search Results

Standard

Comprehensive Life Test for 12 V Automotive Storage Batteries

2007-04-16
HISTORICAL
J2801_200704
This SAE Standard applies to 12 V, flooded and absorptive glass mat lead acid automotive storage batteries of 180 minutes or less reserve capacity and cold crank capacity greater than 200 amperes. This life test is considered to be comprehensive in terms of battery manufacturing technology; applicable to lead-acid batteries containing wrought or cast positive grid manufacturing technology and providing a reasonable correlation for hot climate applications. This document is intended as a guide toward standard practice, but may be subject to change to keep pace with experience and technical advances.
Standard

Comprehensive Life Test for 12 V Automotive Storage Batteries

2013-08-14
HISTORICAL
J2801_201308
This SAE Standard applies to 12 V, flooded and absorptive glass mat lead acid automotive storage batteries of 200 minutes or less reserve capacity and cold crank capacity greater than 200 amperes. This life test is considered to be comprehensive in terms of battery manufacturing technology; applicable to lead-acid batteries containing wrought or cast positive grid manufacturing technology and providing a reasonable correlation for hot climate applications. This document is intended as a guide toward standard practice, but may be subject to change to keep pace with experience and technical advances.
Standard

Comprehensive Life Test for 12 V Automotive Storage Batteries

2018-05-07
CURRENT
J2801_201805
This SAE Standard applies to 12 V, flooded and absorptive glass mat lead acid automotive storage batteries of 200 minutes or less reserve capacity and cold crank capacity greater than 200 amperes. This life test is considered to be comprehensive in terms of battery manufacturing technology; applicable to lead-acid batteries containing wrought or cast positive grid manufacturing technology and providing a reasonable correlation for hot climate applications. This document is intended as a guide toward standard practice, but may be subject to change to keep pace with experience and technical advances.
Standard

LIFE TEST FOR AUTOMOTIVE STORAGE BATTERIES

1982-06-01
HISTORICAL
J240_198206
This SAE Recommended Practice applies to 12 V, automotive storage batteries of 180 min or less reserve capacity. This life test simulates automotive service when the battery operates in a voltage regulated charging system. It subjects the battery to charge and discharge cycles comparable to those encountered in automotive service. Other performance and dimensional information is contained in the latest issue of SAE J537. This SAE Recommended Practice is intended as a guide toward standard practice, but may be subject to change to keep pace with experience and technical advances.
Standard

LIFE TEST FOR AUTOMOTIVE STORAGE BATTERIES

1971-05-01
HISTORICAL
J240_197105
This life test simulates automotive service where the battery operates in a voltage regulated charging system. This test subjects the battery to charge and discharge cycles resulting in failure modes comparable to those encountered in automotive service. 1 The battery is tested in a water bath maintained at 105 ± 5 F. 2 The test cycle is performed as follows: Discharge: 2 min at 25 A Charge: (a) maximum voltage — 14.8 (b) maximum rate — 25 A (c) time — 10 min 3 The battery is continuously cycled for 100 h (for example, Mon day noon until 4:00 p.m. Friday).
Standard

LIFE TEST FOR HEAVY-DUTY STORAGE BATTERIES

1997-09-01
HISTORICAL
J2185_199709
This SAE Recommended Practice applies to 12 V storage batteries which operate in a voltage regulated charging system. It simulates heavy-duty applications by subjecting the battery to deeper discharge and charge cycles than those encountered in starting a vehicle. The deeper discharge and charge cycles in service may come from a combination of the following conditions: a Frequent occurrences of total electrical load exceeding the alternator output. b Frequent occurrences of battery system supplying the electrical loads when the engine is not operating. c Frequent occurrences of prolonged vehicle storage combined with high vehicle key-off loads. Batteries will be classified into two types for this life test. Type 1 applies to batteries with reserve capacity of 200 min or less. Type 2 applies to batteries with reserve capacity greater than 200 min. (“C” value for Type 1 equals 25.0; “C” value for Type 2 equals 50.0.)
Standard

Life Test for Automotive Storage Batteries

2007-04-24
HISTORICAL
J240_200704
This SAE Standard applies to 12 V, flooded lead acid automotive storage batteries of 180 minutes or less reserve capacity using cast positive grid technology only. This life test simulates automotive service when the battery operates in a voltage regulated charging system. It subjects the battery to charge and discharge cycles comparable to those encountered in automotive service. Other performance and dimensional information is contained in the latest issue of SAE J537. This document is intended as a guide toward standard practice, but may be subject to change to keep pace with experience and technical advances.
Standard

Life Test for Automotive Storage Batteries

2012-12-03
CURRENT
J240_201212
This SAE Standard applies to 12 V, flooded lead acid automotive storage batteries of 180 minutes or less reserve capacity using cast positive grid technology only. This life test simulates automotive service when the battery operates in a voltage regulated charging system. It subjects the battery to charge and discharge cycles comparable to those encountered in automotive service. Other performance and dimensional information is contained in the latest issue of SAE J537. This document is intended as a guide toward standard practice, but may be subject to change to keep pace with experience and technical advances.
Standard

Life Test for Heavy-Duty Storage Batteries (Lead Acid Type only)

2018-01-24
CURRENT
J2185_201801
This SAE Standard applies to lead-acid 12 V heavy-duty storage batteries as described in SAE J537 and SAE J930 for uses in starting, lighting and ignition (SLI) applications on motor vehicles and/or off-road machines. These applications have some of the following characteristics: a High levels of power are required to start the vehicle’s internal combustion engine. The need to supply this power limits the maximum depth of discharge to a fraction of the total capacity of the battery.
Standard

Life Test for Heavy-Duty Storage Batteries (Lead Acid Type only)

2012-02-21
HISTORICAL
J2185_201202
This SAE Standard applies to lead-acid 12 V heavy-duty storage batteries as described in SAE J537 and SAE J930 for uses in starting, lighting and ignition (SLI) applications on motor vehicles and/or off-road machines. These applications have some of the following characteristics: a High levels of power are required to start the vehicle’s internal combustion engine. The need to supply this power limits the maximum depth of discharge to a fraction of the total capacity of the battery.
Standard

STORAGE BATTERIES

1992-06-01
HISTORICAL
J537_199206
This SAE Standard serves as a guide for testing procedures and as a publication providing a record of current production batteries, their ratings, and container description. Any battery with planned significant usage may be submitted for inclusion in the Tables of use. (Reference Section 5 and Chart A1 of the Appendix.)