Refine Your Search

Topic

Author

Search Results

Viewing 1 to 20 of 20796
Standard

(R) Dedicated Short Range Communications (DSRC) Message Set Dictionary

2009-11-19
HISTORICAL
J2735_200911
This SAE Standard specifies a message set, and its data frames and data elements specifically for use by applications intended to utilize the 5.9 GHz Dedicated Short Range Communications for Wireless Access in Vehicular Environments (DSRC/WAVE, referenced in this document simply as “DSRC”), communications systems. Although the scope of this Standard is focused on DSRC, this message set, and its data frames and data elements have been designed, to the extent possible, to also be of potential use for applications that may be deployed in conjunction with other wireless communications technologies. This Standard therefore specifies the definitive message structure and provides sufficient background information to allow readers to properly interpret the message definitions from the point of view of an application developer implementing the messages according to the DSRC Standards.
Standard

280 RELAY FOOTPRINT

1994-06-01
CURRENT
J1744_199406
This SAE Standard covers a terminal footprint for mini and micro relays used in surface vehicle electrical systems.
Standard

3GCN - SEAT DISTRIBUTION SYSTEM

2014-08-15
CURRENT
ARINC809-3
This specification defines general architectural philosophy and specific design guidance for the proper installation and interface of various cabin equipment within the seats. Consistency with this specification allows each component installed on the seat to operate in concert when integrated with other relevant cabin type equipment. Standard electrical and mechanical interfaces of the In- Flight Entertainment System (IFES) equipment for the 3rd Generation Cabin Network (3GCN) associated with the seat are defined. This equipment consists of the headphone jacks (HPJ), passenger control unit (PCU)/multi function handset (including the cord), seat video display (SVD), remote data outlet (RDO), integrated seat box (ISB) which includes the seat power box (SPB)/seat data box (SDB), remote power outlet (RPO), and in-seat cables. Appropriate definitions are also provided for other electrical devices associated with the seat control/position mechanism.
Standard

400 Hz CONNECTION AIRCRAFT ELECTRICAL MAINTENANCE PROCEDURES

1994-12-01
HISTORICAL
AIR4365
This SAE Aerospace Information Report (AIR) describes field-level procedures to determine if 400 Hz electrical connections for external power may have been subjected to excessive wear, which may result in inadequate disengagement forces.
Standard

400 Hz Connection Aircraft Electrical Maintenance Procedures

2008-03-28
HISTORICAL
AIR4365A
This SAE Aerospace Information Report (AIR) describes field-level procedures to determine if 400 Hz electrical connections for external power may have been subjected to excessive wear, which may result in inadequate disengagement forces.
Standard

400-CYCLE GROUND POWER UNIT PROVISIONS FOR AIRCRAFT ELECTRICAL SYSTEM PROTECTION

2002-12-16
CURRENT
ARP760
This SAE Recommended Practice which defines the terms and tabulates the limits of the characteristics for various protective devices used in conjunction with 400-cycle ground power for civil aircraft is intended to assist the airlines in standardizing on 400-cycle protective systems. The limits found to be acceptable in the civil aircraft industry are presented.
Standard

60 V and 600 V Single Core Cables

2001-03-07
HISTORICAL
J2183_200103
This SAE Standard specifies the test methods, dimensions, and requirements for single core 60 V cables intended for use in road vehicle applications where the nominal system voltage ≤60 V DC (25 V AC). It also specifies additional test methods and/or requirements for 600 V cables intended for use in road vehicle applications where the nominal system voltage is >60 V DC (25 V AC) to ≤600 V DC (600 V AC). Where practical, this standard uses ISO 6722 for test methods, dimensions, and requirements. This standard covers ISO conductor sizes which usually differ from SAE conductor sizes. It also covers the individual cores in multicore cables. See ISO 6722 for “Temperature Class Ratings”.
Standard

60 V and 600 V Single-Core Cables

2006-04-25
HISTORICAL
J2183_200604
This Standard specifies the test methods, dimensions, and requirements for single-core 60 V cables intended for use in road vehicle applications where the nominal system voltage ≤ 60 V DC (25 V AC). It also specifies additional test methods and/or requirements for 600 V cables intended for use in road vehicle applications where the nominal system voltage is > 60 V DC (25 V AC) to ≤ 600 V DC (600 V AC). Where practical, this standard uses ISO 6722 for test methods, dimensions, and requirements. This standard covers ISO conductor sizes which usually differ from SAE conductor sizes. It also covers the individual cores in multi-core cables. See ISO 6722 for “Temperature Class Ratings”.
Standard

649 Handbook

2020-02-13
WIP
GEIAHB649B
This handbook is intended to assist the user to understand the ANSI/EIA-649B standard principles and functions for Configuration Management (CM) and how to plan and implement effective CM. It provides CM implementation guidance for all users (CM professionals and practitioners within the commercial and industry communities, DoD, military service commands, and government activities (e.g., National Aeronautics and Space Administration (NASA), North Atlantic Treaty Organization (NATO)) with a variety of techniques and examples. Information about interfacing with other management systems and processes are included to ensure the principles and functions are applied in each phase of the life cycle for all product categories.
Standard

A DYNAMIC TEST METHOD FOR DETERMINING THE DEGREE OF CLEANLINESS OF THE DOWNSTREAM SIDE OF FILTER ELEMENTS

1996-05-01
HISTORICAL
ARP599
This test method describes a procedure for determining the insoluble contamination level of the downstream side of filter elements. Results of this procedure are intended to be used only for evaluation of the effectiveness of various cleaning treatments, or cleanliness of element as received from manufacturers. The data obtained by this procedure do not necessarily indicate, qualitatively or quantitatively, the contamination which may be released by a filter element into a fluid during service use. Because of the wide variety of conditions which may exist in service applications, it is recommended that the user design and conduct his own particular service performance test. (See paragraph 10.1).
Standard

A GUIDE TO THE DEVELOPMENT OF A GROUND STATION FOR ENGINE CONDITION MONITORING

1994-02-01
HISTORICAL
AIR4175
An effective ground station is vital to the successful implementation of an EMS and is a fundamental part of the total monitoring system design. Unlike on-board processing systems which principally use data to indicate when engine maintenance is required, ground stations offer much greater processing power to analyse and manipulate EMS data more comprehensively for both maintenance and logistics purposes. This document reviews the main EMS functions and discusses the operating requirements which will determine the basic design of a ground station, including the interfaces with other maintenance or logistics systems. A brief discussion is also included on some of the more recent advances in EMS ground station technology which have been specifically developed to provide more effective diagnostic capabilities for gas turbine engines. Finally, this document addresses the program management requirements associated with the initial development and on-going support of a ground station.
Standard

A Guide to Extending Times Between Overhaul for Rotorcraft Power Train Transmissions Using Monitoring Data

2020-06-09
CURRENT
AIR6334
Time in Service (TIS), or flight hours, logged in maintenance records against an installed rotorcraft transmission is normally used as the “official” time on wing metric for the transmission’s component wear out inspection interval requirement and, in some instances, retirement change on life limited parts. This AIR addresses traditional methods of transmission TBO extensions and introduces rotorcraft transmission monitoring usage metrics that could be used to modify TIS inspections by tracking torque to determine both loads on life limited parts and component wear. This is a document of the SAE HM-1 Committee intended to be used as a technical information source and is not intended as a legal document or standard. This AIR does not provide detailed implementation steps, but does address general implementation, past experience, concerns and potential benefits.
Standard

A Guide to Landing Gear System Integration

2016-04-10
HISTORICAL
AIR5451
The landing gear system is a major airframe system that needs to be integrated very efficiently to minimize the penalties of weight, cost, dispatch reliability and maintenance. As the landing gear system business develops and large scale teaming arrangements and acquisitions become increasingly common, it may be desirable in some instances to procure an Integrated Landing Gear System. This document provides guidelines and useful references for developing an integrated landing gear system for an aircraft and is divided into four sections: Landing Gear Configuration Requirements (Section 3) Landing Gear Functional Requirements (Section 4) Landing Gear System Integrity Requirements (Section 5) Landing Gear Program Requirements (Section 6) The landing gear system encompasses all landing gear structural and subsystem elements. Structural elements include shock struts, braces, fittings, pins, wheels, tires and brakes.
Standard

A Guide to the Development of a Ground Station for Engine Condition Monitoring

2012-10-08
HISTORICAL
AIR4175A
An effective GSS is vital to the successful implementation of an EMS and is a fundamental part of the total monitoring system design, including asset management. Unlike the on-board part of the EMS which principally uses real time data to indicate when engine maintenance is required, a GSS can offer much greater processing power to comprehensively analyze and manipulate EMS data for both maintenance and logistics purposes. This document reviews the main EMS functions and discusses the operating requirements used to determine the basis design of a GSS, including the interfaces with other maintenance or logistic systems. A brief discussion is also included on some of the more recent advances in GSS technology that have been specifically developed to provide more effective diagnostic capabilities for gas turbine engines.
Standard

A Guideline for Aerospace Platform Fiber Optic Training and Awareness Education Aerospace Fiber Optics Fabricator Hands-on Competencies

2007-06-18
CURRENT
ARP5602/4
This document establishes training guidelines applicable to fiber optic fabricator technical training for individuals involved in the manufacturing, installation, support, integration and testing of fiber optic systems. Applicable personnel include: Managers Engineers Technicians Trainers/Instructors Third Party Maintenance Agencies Quality Assurance Production
X