Technical Paper

Development and Validation of a Finite Element Model for the Polar-II Upper Body

2006-04-03
2006-01-0684
The goal of this study was to develop and validate a finite element (FE) model of the Polar-II pedestrian dummy. An upper body model consisting of the head, neck, shoulder, thorax, and abdomen was coupled with a previously validated model of the lower limb The viscoelastic material properties of the dummy components were determined from dynamic compression tests of shoulder urethane, shoulder rubber and abdominal foam. For validation of the entire upper body, the model was compared with NHTSA response requirements for their advanced frontal dummy (Thor) including head and neck pendulum tests as well as ribcage and abdominal impact tests. In addition, the Polar-II full body FE model was subjected to simulated vehicle-pedestrian impacts that recreated published experiments. Simulated head and pelvis accelerations as well as upper body trajectories reasonably reproduced the experiment.
Technical Paper

Development and Validation of the Finite Element Model for the Human Lower Limb of Pedestrians

2000-11-01
2000-01-SC22
An impact test procedure with a legform addressing lower limb injuries in car-pedestrian accidents has been proposed by EEVC/WG17. Although a high frequency of lower limb fractures is observed in recent accident data, this test procedure assesses knee injuries with a focus on trauma to the ligamentous structures. The goal of this study is to establish a methodology to understand injury mechanisms of both ligamentous damages and bone fractures in car-pedestrian accidents. A finite element (FE) model of the human lower limb was developed using PAM-CRASH™. The commercially available H-Dummy™ lower limb model developed by Nihon ESI for a seated position was modified to represent the standing posture of pedestrians. Mechanical properties for both bony structures and knee ligaments were determined from our extensive literature survey, and were carefully implemented in the model considering their strain rate dependency in order to simulate the dynamic response of the lower limb accurately.
Technical Paper

The Influence of Pelvis Design on the Lateral Pelvic Impact Response of the Polar-II Pedestrian Dummy

2006-04-03
2006-01-0682
Previous studies utilizing the Polar-II pedestrian dummy have suggested the need for a more biofidelic pelvis design in order to improve the overall dummy response kinematics. The current Polar-II dummy pelvis is a rigid steel structure. A preliminary version of a modified deformable pelvis equipped with sensors for measuring internal deflection and load has been designed. The goal of this study was to assess the biofidelity of these two pelves in full-scale tests with the Polar-II dummy that mimic lateral pelvic impact tests on PMHS (post-mortem human subjects) reported in the literature. The force - time, deflection - time, and force - deflection histories were compared to new PMHS response corridors determined using a normalization technique. In all tests with both pelves, the initial response (i.e., the first 3 ms to 5 ms following initial dummy - impactor contact) appeared to be totally determined by the mechanical behavior of the flesh.