Refine Your Search

Topic

Search Results

Viewing 1 to 16 of 16
Technical Paper

A Sensor for Estimating the Liquid Mass Fraction of the Refrigerant Exiting an Evaporator

2000-03-06
2000-01-0976
A traditional method of controlling evaporator superheat in a vapor compression air conditioning system is the thermostatic expansion valve (TXV). Such systems are often used in automotive applications. The TXV depends on superheat to adjust the valve opening. Unfortunately, any amount of superheat causes that evaporator to operate at reduced capacity due to dramatically lower heat transfer coefficients in the superheated region. In addition, oil circulation back to the compressor is impeded. The cold lubricant almost devoid of dissolved refrigerant is quite viscous and clings to the evaporator walls. A system that could control an air conditioner to operate with no superheat would either decrease the size of its existing evaporator while maintaining the same capacity, or potentially increase its capacity with its original evaporator. Also, oil circulation back to the compressor would be improved.
Technical Paper

An Investigation of the Feasibility of Refrigerant Charge Loss Detection Using Low Cost Measurements

1997-02-24
970106
The feasibility of automatically detecting refrigerant charge loss in mobile air conditioning (MAC) systems by analyzing inexpensive dynamic measurements was studied. An indicator of the refrigerant inventory of the evaporator was developed. This measure, termed Time to Temperature Turning (TTT), is based on dynamic measurement of the evaporator outlet refrigerant temperature, and correlates strongly with charge level. TTT correlated well with clutch cycling behavior, a metric which is employed in current shop diagnostic practice to indicate refrigerant charge loss. Laboratory data were generated from a factorial experiment design on the following factors: condenser air inlet temperature, condenser air flow rate, evaporator air inlet temperature, compressor speed, and refrigerant charge. Experiments to date were conducted with a dry evaporator.
Technical Paper

Application of Intermediate Vapor Bypass to Mobile Heat Pump System: Extending Operating Range to Lower Ambient Temperature with Low Pressure Low GWP Fluid

2018-04-03
2018-01-0071
With market share of electric vehicles continue to grow, there is an increasing demand of mobile heat pump for cabin climate control, as it has much higher energy efficiency when compared to electric heating and helps to cut drive range reduction. One big challenge of heat pump systems is that their heating capacities drop significantly when operating at very low ambient temperature, especially for those with low pressure refrigerants. This paper presents a way to improve low ambient temperature heating performance by using intermediate vapor bypass with the outdoor heat exchanger, which works as an evaporator in heat pump mode. The experimental results show a 35% increase of heating capacity at −20 °C ambient with the improved system as compared to the baseline, and heating performance factor also slightly increased when the system is working at higher ambient temperature to reach the same heating capacity as the baseline.
Technical Paper

Combustion Chamber Temperature and Instantaneous Local Heat Flux Measurements in a Spark Ignition Engine

1993-03-01
930217
Cylinder head combustion chamber and piston temperatures and heat fluxes were measured in a 2.2 L 4 cylinder spark ignition engine. Measurements for the combustion chamber were made at wide open throttle conditions, 1400 rpm to 5000 rpm at 600 rpm increments, additional measurements were made on the combustion chamber at part throttle conditions at 3200 RPM. Piston temperature and heat flux measurements were made at WOT conditions from 1400 to 3200 RPM in 600 RPM increments. Average combustion chamber surface temperatures ranged from 130 deg. C to 248 deg. C, while peak combustion chamber surface temperatures ranged from 142 deg. C to 258 deg. C for WOT conditions. Peak heat flus at the surface for WOT conditions in the combustion chamber ranged from 1.2 MW/m2to 5.0 MW/m2. Central region heat fluxes were 2.3 to 2.8 times greater than those in the end gas regions of the combustion chamber.
Technical Paper

Continuous Multicomponent Fuel Film Vaporization Model for Multidimensional Engine Modeling

2005-04-11
2005-01-0209
A multicomponent fuel film vaporization model using continuous thermodynamics is developed for multidimensional spray and wall film modeling. The vaporization rate is evaluated using the turbulent boundary-layer assumption and a quasi-steady approximation. Third-order polynomials are used to model the fuel composition profiles and the temperature within the liquid phase in order to predict accurate surface properties that are important for evaluating the mass and moment vaporization rates and heat flux. By this approach, the governing equations for the film are reduced to a set of ordinary differential equations and thus offer a significant reduction in computational cost while maintaining adequate accuracy compared to solving the governing equations for the film directly.
Technical Paper

Dynamic Model of a Springless Electrohydraulic Valvetrain

1997-02-24
970248
A dynamic model for the springless electrohydraulic valvetrain has been developed. The model speeds up the valvetrain development process by simulating effects of parameter changes, thus minimizing the number of hardware variations. It includes dynamic characteristics of check valves that enable energy recovery, hydraulic snubbers that limit seating velocity of the engine valves, and leakage in the control solenoids. A good match of the experimental data has been obtained for a single valve system, and the model calibration and validation have been completed. The known parameters are used together with some unknown calibration constants which have been tuned to match the experimental data. The simulation results for a twin valve system are also presented. The model applications for system performance analysis and for the closed-loop control of the engine valve lift are described. The cyclic variability of the experimental data is also discussed.
Technical Paper

Improving Energy Efficiency in Automotive Vapor Compression Cycles through Advanced Control Design

2006-04-03
2006-01-0267
This paper presents an experimental analysis of the performance of various control strategies applied to automotive air conditioning systems. A comparison of the performance of a thermal expansion valve (TEV) and an electronic expansion valve (EEV) over a vehicle drive cycle is presented. Improved superheat regulation and minor efficiency improvements are shown for the EEV control strategies. The efficiency benefits of continuous versus cycled compressor operation are presented, and a discussion of significant improvements in energy efficiency using compressor control is provided. Dual PID loops are shown to control evaporator outlet pressure while regulating superheat. The introduction of a static decoupler is shown to improve the performance of the dual PID loop controller. These control strategies allow for system capacity control, enabling continuous operation and achieving significant energy efficiency improvements.
Technical Paper

Methods for Detection of Lubrication Failure Applied to a Swashplate Compressor

2000-03-06
2000-01-0974
Understanding lubrication failures at the shoe/swashplate contact of automotive swashplate compressors will greatly enhance the reliability of the air conditioning system. Maintaining proper lubrication is not always possible during transient conditions. Therefore, a method for detection of lubricant loss is of great interest to the automotive industry. Three methods for detecting lubrication loss were examined: contact resistance, acoustic emission, and dynamic pressure oscillations. A mobile air conditioning test stand capable of recording many system parameters was used. Oil return to the compressor was monitored using an oil separator and a refrigerant/oil concentration sensor. Data were taken during steady oil return rates and after oil shut off. The electrical contact resistance between the shoe and swashplate was used to indicate changes in the lubrication conditions at this critical interface. Measurements were taken at two oil return rates during steady oil return tests.
Technical Paper

Modeling of an Integrated Internal Heat Exchanger and Accumulator in R744 Mobile Air-Conditioning Applications

2020-04-14
2020-01-0153
Carbon dioxide (CO2 or R744) is a promising next-generation refrigerant for mobile air-conditioning applications (MAC), which has the advantages of good heating performance in cold climates and environmental-friendly properties. This paper presents a simulation model of an integrated internal heat exchanger (IHX) and accumulator (Acc) using the finite volume method. The results are validated by a group of experimental data collected with different transcritical R744 mobile air-conditioner and heat pump (MHP) systems, and the error was within ±10%. The impacts of refrigerant mass flow rate and operating temperatures on the heat transfer rate of the IHX, improvement on refrigeration capacity and the liquid level in the Acc were studied. Results show that the net benefits of IHX are significant in AC mode, while it helps preventing flooding of the compressor in MHP mode.
Technical Paper

Numerical Simulation of Two-Phase Flow in the Second Header of MAC Condenser

2019-04-02
2019-01-1065
Phase separation circuiting have been proved in the past to effectively improve the performance of mobile air conditioning (MAC) condensers. In the vertical second header of the condenser, liquid separates from vapor mainly due to gravity, leaving vapor-rich flow with higher heat transfer coefficient to go into the upper passes. The condenser effectiveness is improved in this way. However, separation is usually not perfect, expressed through the separation efficiency (ηl and ηv). This paper presents the numerical study of phase separation phenomena in the second header. The Euler-Euler method of Computational Fluid Dynamics (CFD) is used. Simulations are conducted for two-phase refrigerant R-134a for MAC application. Inlet mass flow rate is simulated at values of 16 g∙s-1, 20 g∙s-1, and 30 g∙s-1 for 21 inlet microchannel tubes, which is the same 1st-pass tube number as of a real separation condenser. Corresponding mass fluxes are 166 kg∙m-2∙s-1, 207 kg∙m-2∙s-1, and 311 kg∙m-2∙s-1.
Technical Paper

Real-Time Modeling of Liquid Cooling Networks in Vehicle Thermal Management Systems

2008-04-14
2008-01-0386
This paper describes a ‘toolbox’ for modeling liquid cooling system networks within vehicle thermal management systems. Components which can be represented include pumps, coolant lines, control valves, heat sources and heat sinks, liquid-to-air and liquid-to-refrigerant heat exchangers, and expansion tanks. Network definition is accomplished through a graphical user interface, allowing system architecture to be easily modified. The elements of the toolbox are physically based, so that the models can be applied before hardware is procured. The component library was coded directly into MATLAB / SIMULINK and is intended for control system development, hardware-in-the-loop (HIL) simulation, and as a system emulator for on-board diagnostics and controls purposes. For HIL simulation and on-board diagnostics and controls, it is imperative that the model run in real-time.
Technical Paper

Refrigerant Charge Imbalance in a Mobile Reversible Air Conditioning-Heat Pump System

2017-03-28
2017-01-0177
This paper presents the study of refrigerant charge imbalance between A/C (cooling) mode and HP (heating) mode of a mobile reversible system. Sensitivities of cooling and heating capacity and energy efficiency with respect to refrigerant charge were investigated. Optimum refrigerant charge level for A/C mode was found to be larger than that for HP mode, primarily due to larger condenser size in A/C mode. Refrigerant charge retention in components at both modes were measured in the lab by quick close valve method. Modeling of charge retention in heat exchangers was compared to experimental measurements. Effect of charge imbalance on oil circulation was also discussed.
Technical Paper

Refrigerant Expansion Noise Propagation Through Downstream Tube Walls

1999-03-01
1999-01-1197
Reductions of noise in vehicle passenger compartments in recent years have made some previously undetectable noises audible. Expansion devices used in automobile air conditioning systems are known producers of noise. The fact that these devices are mounted very close to the passengers increases the problems associated with the reduction of this noise. The understanding of the propagation mechanisms from the noise generated in the refrigerant by the expansion device, through the tube and evaporator walls, and finally to the outside air is important. This paper will focus on how noise from expansion devices is transmitted through tube walls downstream of the expansion valve.
Technical Paper

Sound Evaluation of Flow-Induced Noise with Simultaneous Measurement of Flow Regimes at TXV Inlet of Automotive Evaporators

2020-04-14
2020-01-1255
In the air conditioning system, flow-induced noise is very disturbing, including the noise generated in the expansion device and the heat exchangers. In the past few decades, most researches related to flow-induced noise focused on the relationship between the flow regimes near the expansion device and the amplitude of flow-induced noise when the measurements are not synched. In this paper, an experimental approach is used to explore the simultaneous relationships between flow-induced noise characteristics and flow regimes at the inlet of TXV of evaporators used in automobiles. A pumped R134a loop with microphones and transparent visualization sections is used to simulate the vapor compression system. Also, the paper evaluates the severity of flow-induced noise from not only the amplitude of noise but also the frequency of noise with a parameter called psychoacoustic annoyance (PA).
Technical Paper

Using R744 (CO2) to Cool an Up-Armored M1114 HMMWV

2005-05-10
2005-01-2024
The US Army uses a light tactical High-Mobility Multi-Purpose Wheeled Vehicle (HMMWV) which, due to the amount of armor added, requires air conditioning to keep its occupants comfortable. The current system uses R134a in a dual evaporator, remote-mounted condenser, engine-driven compressor system. This vehicle has been adapted to use an environmentally friendly refrigerant (carbon dioxide) to provide performance, efficiency, comfort and logistical benefits to the Army. The unusual thermal heat management issues and the fact that the vehicle is required to operate under extreme ambient conditions have made the project extremely challenging. This paper is a continuation of work presented at the SAE Alternate Refrigerants Symposium held in Phoenix last June [1].
Technical Paper

Ventilated Brake Rotor Air Flow Investigation

1997-02-24
971033
Air flow through the passages of a Chrysler LH platform ventilated brake rotor is measured. Modifications to the production rotor's vent inlet geometry are prototyped and measured in addition to the production rotor. Vent passage air flow is compared to existing correlations. The inlet modifications show significantly improved vent air flow, over the production rotor. The result improvement in heat transfer and rotor cooling is reported. These benefits in performance should be attainable at very low increases in production cost.
X