Standard

Airport Electrical Power System Harmonics

2020-09-23
CURRENT
AIR5387
This SAE Aerospace Information Report (AIR) is intended to cover all airport 50 or 60 Hz electrical systems as well as all electrical utilization equipment that is attached to those systems.
Standard

Electric Baggage/Cargo Tractor

2011-05-16
HISTORICAL
ARP1804A
This SAE Aerospace Recommended Practice (ARP) outlines the design and performance requirements for a battery-powered electric tow tractor for the handling of baggage or cargo trailers in airline service. The use of “shall” in this document indicates a mandatory requirement. The use of “should” indicates a recommendation or that which is advised but not required.
Standard

GROUND ELECTRICAL POWER UNIT BRUSHLESS, SYNCHRONOUS, ELECTRIC MOTOR-DRIVEN 400 HERTZ, 3-PHASE OUTPUT

1985-08-01
HISTORICAL
ARP1480
This recommended practice outlines the general requirements of a continuous duty, electric motor-driven brushless alternator unit for supplying 400 Hz electrical power to high performance commercial transport aircraft. This specification is for a single motor-generator set with one or two outputs. The generator set will generate at the aircraft voltage of 115/200 volts. This unit may be used in a central system of small size or in hangar or electronic shop applications. Power characteristics of this unit at the receptacle will meet MIL-Standard-704 requirements. Other limits which are necessary to meet specific conditions must be specified by the purchaser.
Standard

GROUND ELECTRICAL POWER UNIT, TRANSPORTABLE 115/200 VOLT AC (NOMINAL) 400 HERTZ, 3-PHASE 4-WIRE (GROUNDED NEUTRAL) Y-CONNECTED SYSTEM

1991-05-01
HISTORICAL
ARP1148A
This Recommended Practice outlines the electrical performance characteristics for a continuous duty, diesel or gasoline engine driven brushless alternator unit for supplying 400-Hertz electrical power to commercial transport aircraft. It is intended to assist the airlines in standardizing recommendations for various sizes and configurations of equipment and it is a guide for the preparation of detailed specifications. The unit is primarily intended to supply power to the aircraft during passenger loading and unloading, and during servicing operations. The combination of the equipment specified herein and the interconnecting cables(s) between the 400-Hertz alternator and the aircraft shall provide power characteristics at the aircraft receptacle which meet MIL-STD-704 requirements for Category "B" equipment. Other limits which are necessary to meet specific conditions must be specified by the purchaser.
Standard

GROUND ELECTRICAL POWER UNIT, TRANSPORTABLE 115/200 VOLT AC (NOMINAL) 400 HERTZ, 3-PHASE 4-WIRE (GROUNDED NEUTRAL) Y-CONNECTED SYSTEM

1970-02-01
HISTORICAL
ARP1148
This Recommended Practice outlines the general requirements for a transportable self-contained, continuous duty, diesel engine driven brushless alternator unit for supplying 400-Hertz electrical power to high performance commercial transport aircraft. It is intended to assist the airlines in standardardizing recommendations for various sizes and configurations of equipment and it is a guide for the preparation of detailed specifications by the purchaser. The unit is primarily intended to supply power to the aircraft during passenger loading and unloading, and during servicing operations at airports throughout the world. The combination of the equipment specified herein and the interconnecting cable(s) between the 400-Hertz alternator and the aircraft shall provide power characteristics at the aircraft receptacle which meet MIL-STD-704A requirements for Category "B" equipment. Other limits which are necessary to meet specific conditions must be specified by the purchaser.
Standard

GROUND EQUIPMENT - 400 HERTZ GROUND POWER PERFORMANCE REQUIREMENTS

1996-06-01
HISTORICAL
ARP5015
This SAE Aerospace Recommended Practice (ARP) covers the requirements for ground power equipment that supplies 115/200 V, 3-phase, 400 Hz output capable of powering aircraft type loads requiring MIL-STD-704E/DFS-400 quality power. All forms of ground power including mobile and fixed systems are addressed by this document. High voltage (270 V DC) systems are not included in this specification.
Standard

Ground Equipment - 400 Hertz Ground Power Performance Requirements

2011-01-14
HISTORICAL
ARP5015A
This SAE Aerospace Recommended Practice (ARP) covers the requirements for ground power equipment that supplies 115/200 V, 3-phase, 400 Hz output capable of powering aircraft type loads requiring MIL-STD-704E/DFS-400 quality power. All forms of ground power including mobile and fixed systems are addressed by this document. High voltage (270 V DC) systems are not included in this specification.
Standard

Ground Support Equipment Electrical Systems

2018-09-27
CURRENT
AIR1336B
This SAE Aerospace Information Report (AIR) considers the following major areas: 1 major components and their ratings; 2 selection criteria for optimum design balance for electrical systems; 3 effects of operating conditions and environment on both maintenance and life of components; 4 trouble signals - their diagnosis and cure.
Standard

Ground Support Equipment Hydraulic Systems, Design and Installation, Recommended Practices for

2022-12-16
CURRENT
ARP4943A
This SAE Aerospace Recommended Practice (ARP) covers the design and installation requirements for hydraulic systems (up to 8000 psig [56 MPa]) for ground support equipment (GSE). This ARP is derived from AS5440, which provides hydraulic system requirements for aircraft. The recommendations herein are primarily intended for GSE that exchange hydraulic fluid with the aircraft, such as hydraulic service carts, rather than GSE with non-interfacing hydraulic systems. The GSE may be mobile, portable, or stationary.
Standard

MINIMUM SAFETY REQUIREMENTS FOR SPECIAL PURPOSE AIRLINE GROUND SUPPORT EQUIPMENT

1998-09-01
HISTORICAL
AIR1375B
This document applies to special purpose equipment, excluding fixed facilities, which is used in the ground handling, servicing, and maintenance of aircraft. Equipment covered under other sections of the Federal Register Part 1910 is excluded from this document. This document is to establish minimum safety requirements and should not be used for vehicle design criteria. Equipment existing prior to publication date is excluded from the requirements of this document.
Standard

Minimum Safety Requirements for Special Purpose Airline Ground Support Equipment

2014-05-29
CURRENT
AIR1375D
This document applies to special purpose equipment which is used in the ground handling, servicing, and maintenance of transport aircraft. Fixed airport facilities and equipment covered under other sections of Part 1910 of Code of Federal Regulations (OSHA) are excluded from the scope of this document.
Standard

Minimum Safety Requirements for Special Purpose Airline Ground Support Equipment

2000-06-01
HISTORICAL
AIR1375C
This document applies to special purpose equipment which is used in the ground handling, servicing, and maintenance of transport aircraft. Fixed airport facilities and equipment covered under other sections of Part 1910 of Code of Federal Regulations (OSHA) are excluded from the scope of this document.
Standard

Pictograms for Ground Support Equipment

1999-12-01
HISTORICAL
ARP1838A
This SAE Aerospace Recommended Practice (ARP) specifies pictographic symbols for ground support equipment. They have been compiled for the benefit of those who deal with such equipment like airlines, airport authorities, manufacturers etc. in order to facilitate fast and accurate identification of controls, indicators, and decals of powered and unpowered equipment. This document shall promote standardization of terms for controls, indicators etc. of ground support equipment and eliminate language problems. It is recommended to put these pictograms on all future equipment and to retrofit all existing equipment as far as possible.
Standard

VEHICLE ELECTRICAL SYSTEMS

2007-08-29
HISTORICAL
AIR1336A
This SAE Aerospace Information Report (AIR) considers the following major areas: 1 Major components and their ratings 2 Selection criteria for optimum design balance for electrical systems 3 Effects of operating conditions and environment on both maintenance and life of components 4 Trouble signals—their diagnosis and cure
Standard

VEHICLE ELECTRICAL SYSTEMS

1975-05-01
HISTORICAL
AIR1336
This document considers the following major areas: 1 Major components and their ratings 2 Selection criteria for optimum design balance for electrical systems 3 Effects of operating conditions and environment on both maintenance and life of components 4 Trouble signals -- their diagnosis and cure