Standard

1000BASE-T1 Un-Shielded and Shielded Balanced Single Twisted Pair Ethernet Cable

2021-11-03
J3117/2_202111
This standard covers un-shielded (JUTP) and shielded (STP) balanced single twisted pair jacketed data cable intended for use in surface vehicle cables for 1 Gb/s ethernet applications. The tests in this standard are intended to qualify cables for normal operation in an automotive environment while maintaining the necessary electrical properties for reliable data transmission.
Standard

1000BASE-T1 Un-Shielded and Shielded Balanced Single Twisted Pair Ethernet Cable

2022-09-30
J3117/2_202209
This standard covers un-shielded (JUTP) and shielded (STP) balanced single twisted pair jacketed data cable intended for use in surface vehicle cables for 1000BASE-T1 ethernet PHY (1 Gb/s) applications. The tests in this standard are intended to qualify cables for normal operation in an automotive environment while maintaining the necessary electrical properties for reliable data transmission.
Standard

100BASE-T1 Un-Shielded Balanced Single Twisted Pair Ethernet Cable

2023-01-17
J3117/1_202301
This SAE Standard covers un-shielded balanced single twisted pair data cable intended for use in surface vehicle cables for ≤100 Mb/s Ethernet applications. The tests in this document are intended to qualify cables for normal operation in an automotive environment while maintaining the necessary electrical properties for reliable data transmission.
Technical Paper

14/42V - Electrical Power Supply Systems Consequences for Electrical Interconnections and Switches

2000-08-21
2000-01-3055
This paper provides an overview about the consequences of a 14/42 V - Electrical Power Supply System for the Electrical Interconnection and Switching Technology. It presents design guidelines and solutions for connector systems including advanced applications like fuse and relay boxes and gives an overview of those existing connectors already suited for 42 V and even higher voltages. The problem of arcing due to the increased voltage is discussed for the case that mating and unmating under load has to be taken into consideration. Arcing also has a tremendous impact on the design of 42 V proof relays. Therefore, some basic results be presented along with proposals how these problems can be overcome by appropriate designs. Another part of the paper looks at the electrical power supply system itself. Here interconnection techniques for new battery systems are discussed. Finally, the chances for new technologies are highlighted.
Standard

15 Pole Connector Between Towing Vehicles and Trailers with 12 Volt Nominal Supply

2018-04-15
J2691_201804
This SAE standard establishes the minimum construction and performance requirements for a 15 Pole Connector Between Towing Vehicles and Trailers, for trucks, trailers, and dollies in conjunction with SAE J2742. The connector accommodates both power and ISO 11992-1 signal circuits along with dual ground wires to accommodate grounding requirements within the constraints of the SAE J2691 terminal capacity.
Standard

15 Pole Connector Between Towing Vehicles and Trailers with 12 Volt Nominal Supply

2013-04-09
J2691_201304
This SAE standard establishes the minimum construction and performance requirements for a 15 Pole Connector Between Towing Vehicles and Trailers, for trucks, trailers, and dollies in conjunction with SAE J2742 “Combination 11 Conductors and 4 Pairs ECBS Cable”. The connector accommodates both power and ISO 11992-1 signal circuits along with dual ground wires to accommodate grounding requirements within the constraints of the SAE J2691 terminal capacity.
Technical Paper

175°C-Capable Thermoplastic Elastomers for Automotive Air Management and Sealing Applications

2007-11-28
2007-01-2576
Flexibility, oil resistance, and the need for heat resistance to 150°C-plus temperatures have traditionally limited automotive design engineers to two options - thermoset rubber or heat-shielding conventional thermoplastic elastomers (TPE). Both of these options present limitations in part design, the ability to consolidate the number of components in a part of assembly, and on total cost. This paper presents a class of high-performance, flexible thermoplastic elastomers based on dynamically vulcanized polyacrylate (ACM) elastomer dispersed in a continuous matrix of polyamide (PA) thermoplastic. These materials are capable of sustained heat resistance to 150°C and short-term heat resistance to 175°C, without requiring heat shielding. Recent advancements in blow molding and functional testing of the PA//ACM TPEs for automotive air management (ducts) and underhood sealing applications will be shown.
Technical Paper

4 Stroke Gasoline Engine Performance Optimization Using Statistical Techniques

2001-12-01
2001-01-1800
The engine designer has to find novel methods to optimize the engine efficiency faster as the engine development cycle is getting shortened due to the continuous growing market demands. Engine optimization involves fine tuning of the various engine parameters and conducting a large number of tests on actual engine test bed. In this paper, modern techniques that have been used to optimize a small 4stroke air-cooled engine performance have been described. The engine has been modelled using one-dimensional thermodynamic engine modelling software (AVL-BOOST). Design of experiments (DoE) tools have been used to optimize the engine variables. The input parameters form an orthogonal array of L27 matrix and the out put characteristics of the engine (responses) have been predicted by using BOOST software. This design matrix has been used to study and optimize thirteen factors in three levels (313).
Standard

400 Hz CONNECTION AIRCRAFT ELECTRICAL MAINTENANCE PROCEDURES

1994-12-01
AIR4365
This SAE Aerospace Information Report (AIR) describes field-level procedures to determine if 400 Hz electrical connections for external power may have been subjected to excessive wear, which may result in inadequate disengagement forces.
Standard

400 Hz Connection Aircraft Electrical Maintenance Procedures

2008-03-28
AIR4365A
This SAE Aerospace Information Report (AIR) describes field-level procedures to determine if 400 Hz electrical connections for external power may have been subjected to excessive wear, which may result in inadequate disengagement forces.
Standard

400-CYCLE GROUND POWER UNIT PROVISIONS FOR AIRCRAFT ELECTRICAL SYSTEM PROTECTION

2002-12-16
ARP760
This SAE Recommended Practice which defines the terms and tabulates the limits of the characteristics for various protective devices used in conjunction with 400-cycle ground power for civil aircraft is intended to assist the airlines in standardizing on 400-cycle protective systems. The limits found to be acceptable in the civil aircraft industry are presented.
Standard

60 V and 600 V Single Core Cables

2001-03-07
J2183_200103
This SAE Standard specifies the test methods, dimensions, and requirements for single core 60 V cables intended for use in road vehicle applications where the nominal system voltage ≤60 V DC (25 V AC). It also specifies additional test methods and/or requirements for 600 V cables intended for use in road vehicle applications where the nominal system voltage is >60 V DC (25 V AC) to ≤600 V DC (600 V AC). Where practical, this standard uses ISO 6722 for test methods, dimensions, and requirements. This standard covers ISO conductor sizes which usually differ from SAE conductor sizes. It also covers the individual cores in multicore cables. See ISO 6722 for “Temperature Class Ratings”.
Standard

60 V and 600 V Single-Core Cables

2006-04-25
J2183_200604
This Standard specifies the test methods, dimensions, and requirements for single-core 60 V cables intended for use in road vehicle applications where the nominal system voltage ≤ 60 V DC (25 V AC). It also specifies additional test methods and/or requirements for 600 V cables intended for use in road vehicle applications where the nominal system voltage is > 60 V DC (25 V AC) to ≤ 600 V DC (600 V AC). Where practical, this standard uses ISO 6722 for test methods, dimensions, and requirements. This standard covers ISO conductor sizes which usually differ from SAE conductor sizes. It also covers the individual cores in multi-core cables. See ISO 6722 for “Temperature Class Ratings”.
Standard

60 V and 600 V Single-Core Cables

2012-09-07
J2183_201209
This Standard specifies the test methods, dimensions, and requirements for single-core 60 V cables intended for use in road vehicle applications where the nominal system voltage ≤ 60 V DC (25 V AC). It also specifies additional test methods and/or requirements for 600 V cables intended for use in road vehicle applications where the nominal system voltage is > 60 V DC (25 V AC) to ≤ 600 V DC (600 V AC). Where practical, this standard uses ISO 6722 for test methods, dimensions, and requirements. This standard covers ISO conductor sizes which usually differ from SAE conductor sizes. It also covers the individual cores in multi-core cables. See ISO 6722 for “Temperature Class Ratings”.
Technical Paper

A CFD Multidimensional Approach to Hydraulic Components Design

2007-10-30
2007-01-4196
This paper presents a multidimensional approach to the hydraulic components design by means of an open-source fluid dynamics code. A preliminary study of a basic geometry was carried out by simulating the efflux of an incompressible fluid through circular pipes. Both laminar and turbulent conditions were analyzed and the influence of the grid resolution and modeling settings were investigated. A qualitative description of the internal flow-field distribution, and a quantitative comparison of pressure and velocity profiles along the pipe axis were used to asses the multidimensional open-source code capabilities. Moreover the results were compared with the experimental measurements available in literature and with the theoretical trends which can be found in well-known literature fundamentals (Hagen-Poiseuille theory and Nikuradse interpolation). Further comparison was performed by using a commercial CFD code.
Technical Paper

A Camera Installation in a Pressurized Part 23 Aircraft

2004-04-20
2004-01-1808
This paper describes some of the steps necessary to certificate a camera installation in a Part 23 aircraft. The camera is large and necessitates the severing of a major structural member (keel beam). Damage tolerance analysis is required because of the penetration of the pressure vessel. Cable rerouting is necessary because of the location of the hole. The design, the basis for the structural substantiation and the structural substantiation of this design are discussed in this paper.
Technical Paper

A Comparison of Numerical Techniques for the Study of Lightning Indirect Effects

2001-09-11
2001-01-2894
A comparison of various numerical tools and techniques was performed for calculating the lightning indirect effects to composite structures and internal systems. This paper is a summary of the initial comparison results. Detailed results of each technique considered are given in additional separate papers presented during this conference. The modeling considered current distributions over and within composite surfaces and the coupling of current and voltages to internal systems such as wire bundle cables and hydraulic and fuel tubes. The models were compared to each other and to measured data from low level swept continuous wave (LLCW) tests performed on two test fixtures. Other features of the codes such as run time, ease of use, computer requirements, availability of documentation and technical support, etc. are compared as well.
Technical Paper

A Comprehensive and Efficient Model of Belt-Drive Systems

2010-04-12
2010-01-1058
Belt-drive systems are a commonly used for power transmission in automotive applications, notably in engine and vehicle auxiliary subsystem drives. In order to characterize the physics of a belt drive system and its response to speed and load excitations, a comprehensive model of belt elasticity and of belt-pulley contact and friction is required. In practical applications such models are utilized in parametric design and optimization studies, and computational efficiency is therefore also a key requirement. In this paper a belt drive dynamics model is presented, in which the belt is modeled by means of geometrically exact cables that can undergo large rigid body motions but whose strains remain small. The Finite Element approach is used in order to efficiently discretize these elastic components. In addition, a state-of-the-art dynamic friction model (LuGre) is used in order to model the friction loads between the belt and pulleys.