265°F, Autoclave Vacuum Bag Cure, Epoxy Prepreg, Type 40, Class 2, Grade 195, Style 3K-PW, Standard Modulus Carbon Fiber
AMS6568/2
The purpose of this specification is to allow procurement of a defined material corresponding to statistically derived material properties published in CMH-17. This material is intended for use in laminate applications with a service temperature up to 180 °F. They are typically used in structural applications requiring high strength and stiffness.
Rationale: Widely distributed and available industry material specifications are required for procurement of composite materials whose allowables data is published in CMH-17.