Low Speed Thorax Impact Test Procedure for the HIII5F Dummy
J2878_202206
This procedure establishes a recommended practice for performing a Low Speed Thorax Impact Test to the Hybrid III Small Female Anthropomorphic Test Device (ATD or crash dummy). This test was created to satisfy the demand by the industry to have a certification test which results in peak chest deflection similar to current full vehicle, frontal impact tests. An inherent problem exists with the current certification procedure because the normal (6.7 m/s) thorax impact test has test results for peak chest deflection that are greater than those currently seen in full vehicle, frontal tests.
The intent of this document is to develop a low speed thorax certification procedure for the H-III5F dummy with a 3.0 m/s impact similar to the SAE J2779 procedure for the H-III50M dummy.
Rationale:
Section 2.1.1 SAE EA-25 was replaced by SAE J2862.Section 2.2.1 Company name and link replaced with text indicating working link where documents can be obtained.Section 3.3 Change upper limit of hysteresis corridor from 72 to 79.SAE J2878 has been reaffirmed to comply with the SAE Five-Year Review policy.
Related Topics:
Anthropometric test devices
Impact tests
Torso
Frontal collisions
Leg
Neck
Humidity
Also known as: SAE J 2878