Two-Phase Capillary-Pumped Loop: A Potential Heat Transport System 891466
This paper presents the general objectives, the design concept and the potential performances of the two-phase capillary pumping loop (CPL) as a heat transportation system.
In particular the actual design of the ESA funded development program “CPL”, designed and developped by SABCA and DORNIER will be shown as well as of its development status.
Results obtained with the first breadboard CPL model are reported together with comparison of predicted against tested performances.
Citation: Bhatti, R., Oost, S., Supper, W., and Wulz, H., "Two-Phase Capillary-Pumped Loop: A Potential Heat Transport System," SAE Technical Paper 891466, 1989, https://doi.org/10.4271/891466. Download Citation
Author(s):
R. S. Bhatti, S. Van Oost, W. Supper, H. Wulz
Affiliated:
SABCA
Pages: 8
Event:
Intersociety Conference on Environmental Systems
ISSN:
0148-7191
e-ISSN:
2688-3627
Related Topics:
Pumps
SAE MOBILUS
Subscribers can view annotate, and download all of SAE's content.