Refine Your Search

Topic

Author

Search Results

Technical Paper

Monitoring Pre-Combustion Event Markers by Heating Electrical Wires

2009-07-12
2009-01-2543
Simultaneous measurements were made for particle releases and off-gassing products produced by heating electrical wires. The wire samples in these experiments were heated to selected temperatures in a heating chamber and responses to vapor releases were recorded by the JPL Electronic Nose (ENose) and an Industrial Scientific ITX gas-monitor; particles released were detected by a TSI P-Trak particle counter. The temperature range considered for the experiment is room temperature (24−26°C) to 500 °C. The results were analyzed by overlapping responses from the ENose, ITX gas sensors and P-Trak, to understand the events (particle release/off-gassing) and sequence of events as a function of temperature and to determine qualitatively whether ENose may be used to detect pre-combustion event markers.
Technical Paper

Monitoring Space Shuttle Air for Selected Contaminants Using an Electronic Nose

1998-07-13
981564
A miniaturized electronic nose has been constructed at JPL in collaboration with Caltech. This array of conductometric sensors has been trained to detect and quantify the presence of vapors in the air; the compounds detected have been found as contaminants in shuttle air. This device has potential application as a miniature, distributed device for monitoring and controlling the constituents in air.
Technical Paper

Noise Environment Reduction Foam Spheres in Space

1989-09-01
892373
The advent of lightweight fairings for new spacecraft and the increased thrust of new launch vehicles have intensified the need for better techniques for predicting and for reducing the low frequency noise environment of spacecraft at lift-off. This paper presents a VAPEPS (VibroAcoustic Payload Environment Prediction System) parametrical analysis of the noise reduction of spacecraft fairings and explores a novel technique for increasing the low frequency noise reduction of lightweight fairings by approximately 10 dB.
Journal Article

Off-Gassing and Particle Release by Heated Polymeric Materials

2008-06-29
2008-01-2090
Polymers are one of the major constituents in electrical components. A study investigating pre-combustion off-gassing and particle release by polymeric materials over a range of temperatures can provide an understanding of thermal degradation prior to failure which may result in a fire hazard. In this work, we report simultaneous measurements of pre-combustion vapor and particle release by heated polymeric materials. The polymer materials considered for the current study are silicone and Kapton. The polymer samples were heated over the range 20 to 400°C. Response to vapor releases were recorded using the JPL Electronic Nose (ENose) and Industrial Scientific's ITX gas monitor configured to detect hydrogen chloride (HCl), carbon monoxide (CO) and hydrogen cyanide (HCN). Particle release was monitored using a TSI P-TRAK particle counter.
Journal Article

On-Orbit Performance of the Moon Mineralogy Mapper Instrument

2009-07-12
2009-01-2390
Launched on India's Chandrayaan-1 spacecraft on October 22, 2008, JPL's Moon Mineralogy Mapper (M3) instrument has successfully completed over six months of operation in space. M3 is one in a suite of eleven instruments, six of which are foreign payloads, flying onboard the Indian spacecraft. Chandrayaan-1, managed by the Indian Space Research Organization (ISRO) in Bangalore, is India's first deep space mission. Chandrayaan-1 was launched on the upgraded version of India's Polar Satellite Launch Vehicle (PSLV-XL) from the Satish Dhawan Space Centre, SHAR, Sriharikota, India. The primary science objective of the M3 instrument is the characterization and mapping of the lunar surface composition in the context of its geologic evolution. Its primary exploration goal is to assess and map the Moon mineral resources at high spatial resolution to support future targeted missions.
Technical Paper

On-Orbit Performance of the TES Loop Heat Pipe Heat Rejection System

2008-06-29
2008-01-2000
Launched on NASA's Aura spacecraft on July 15, 2004, JPL's Tropospheric Emission Spectrometer (TES) has been operating successfully for over three years in space. TES is an infrared high resolution, imaging fourier transform spectrometer with spectral coverage of 3.3 to 15.4 μm to measure and profile essentially all infrared-active molecules present in the Earth's lower atmosphere. It measures the three-dimensional distribution of ozone and its precursors in the lower atmosphere on a global scale. The Aura spacecraft was successfully placed in a sun-synchronous near-circular polar orbit with a mean altitude of 705 km and 98.9 minute orbit period. The observatory is designed for a nominal 5 year mission lifetime. The instrument thermal design features include four temperature zones needed for efficient cryogenic staging to provide cooling at 65 K, 180 K, 230 K and 300 K.
Journal Article

On-Orbit Thermal Performance of the TES Instrument-Three Years in Space

2008-06-29
2008-01-2118
The Tropospheric Emission Spectrometer (TES), launched on NASA's Earth Observing System Aura spacecraft on July 15, 2004 has successfully completed over three years in space and has captured a number of important lessons. The instrument primary science objective is the investigation and quantification of global climate change. TES measures the three-dimensional distribution of ozone and its precursors in the lower atmosphere on a global scale. It is an infrared (IR) high resolution, imaging Fourier Transform Spectrometer (FTS) with a 3.3 to 15.4 μm spectral coverage required for space-based measurements to profile essentially all infrared-active molecules present in the Earth's lower atmosphere. The nominal on-orbit mission lifetime is 5 years. The Aura spacecraft flies in a sun-synchronous near-circular polar orbit with 1:38 pm ascending node.
Technical Paper

Operation of Third Generation JPL Electronic Nose on the International Space Station

2009-07-12
2009-01-2522
The Third Generation ENose is an air quality monitor designed to operate in the environment of the US Lab on the International Space Station (ISS). It detects a selected group of analytes at target concentrations in the ppm regime at an environmental temperature range of 18 – 30 °C, relative humidity from 25 – 75% and pressure from 530 to 760 torr. This device was installed and activated on ISS on Dec. 9, 2008 and has been operating continuously since activation. Data are downlinked and analyzed weekly. Results of analysis of ENose monitoring data show the short term presence of low concentration of alcohols, octafluoropropane and formaldehyde as well as frequent short term unknown events.
Technical Paper

Operation of an Electronic Nose Aboard the Space Shuttle and Directions for Research for a Second Generation Device

2000-07-10
2000-01-2512
A flight experiment to test the operation of an Electronic Nose developed and built at JPL and Caltech was done aboard STS-95 in October-November, 1998. This ENose uses conductometric sensors made of insulating polymer-carbon composite films; it has a volume of 1.7 liters, weighs 1.4 kg including the operating computer and operates on 1.5 W average power. In the flight experiment, the ENose was operated continuously for 6 days and recorded the sensors' response to changes in air in the mid-deck of the orbiter. The ENose had been trained to identify and quantify ten common contaminants at the 24-hour Spacecraft Maximum Allowable Concentration (SMAC) level. Most SMACs are on the order of 10-100 ppm. The experiment was controlled by collecting air samples daily and analyzing them using standard analytical techniques after the flight. The device is microgravity insensitive.
Technical Paper

Operational Thermal Control of Cassini Titan Flybys

2003-07-07
2003-01-2685
The Cassini spacecraft will make 45 targeted flybys of Saturn's largest moon, Titan. 25 flybys will have a relatively low closest approach target altitude in Titan's atmosphere. An operational thermal control strategy has been developed for these flybys. The challenge met was to provide flyby operational thermal control that enabled science and remained within design limitations and Project constraints. Thermal engineers adopted a Systems-level approach that insured appropriate risk mitigation and information accuracy. This paper focuses on the technical thermal control evaluation and strategy, the Systems-level approach taken, and lessons learned and recommendations in an operations environment.
Technical Paper

Overview of the Vehicle Cabin Atmosphere Monitor, a Miniature Gas Chromatograph/Mass Spectrometer for Trace Contamination Monitoring on the ISS and CEV

2007-07-09
2007-01-3150
Work is underway to deliver an instrument for analysis of the atmosphere aboard the International Space Station. The Vehicle Cabin Atmosphere Monitor (VCAM) is based on a low-mass, low-power miniature preconcentrator gas chromatograph/mass spectrometer (PCGC/MS) capable of providing sub-ppm measurements of volatile constituents in a space vehicle or outpost. VCAM is designed to operate autonomously, maintenance-free, once per day, with its own carrier and calibration gas supplies sufficient for a one-year lifetime. VCAM performance is sufficient to detect and identify 90% of the target compounds specified at their 180-day Spacecraft Maximum Allowable Concentration (SMAC) levels. The flight units will be delivered in mid-2008 and be operated in the ISS EXPRESS rack.
Technical Paper

Performance Characteristics of Lithium-Ion Cells for Mars Sample Return Athena Rover

1999-08-02
1999-01-2639
In contrast to the primary batteries (lithium thionyl chloride) on the Sojourner Mars Rover and the upcoming 2001 Mars Rover, the Mars Sample Return (MSR) Athena Rover will utilize rechargeable lithium ion batteries, following the footsteps of MSP 2001 Lander. The MSR Athena Rover will contain a rechargeable lithium ion battery of 16 V and a total energy of 150 Wh. The mass and volume of the projected power system will be a maximum of 3 kg and 2 liters, respectively. Each battery consists of twelve cells (6-7 Ah), combined in three parallel strings of four cells (16 V) each, such that the capability of the Rover shall be maintained even in the event of one string failure. In addition to usual requirements of high specific energy and energy density and long cycle life (100 cycles), the battery is required to operate at wide range of temperatures, especially at sub-zero temperatures down to -20°C.
Technical Paper

Performance Characteristics of Lithium-Ion Cells for NASA’s Mars 2001 Lander Application

1999-08-02
1999-01-2638
NASA requires lightweight rechargeable batteries for future missions to Mars and the outer planets that are capable of operating over a wide range of temperatures, with high specific energy and energy densities. Due to the attractive performance characteristics, lithium-ion batteries have been identified as the battery chemistry of choice for a number of future applications, including Mars rovers and landers. The Mars 2001 Lander (Mars Surveyor Program MSP 01) will be among one of the first missions which will utilize lithium-ion technology. This application will require two lithium-ion batteries, each being 28 V (eight cells), 25 Ah and 8 kg. In addition to the requirement of being able to supply at least 200 cycles and 90 days of operation upon the surface of Mars, the battery must be capable of operation (both charge and discharge) at temperatures as low as -20°C.
Technical Paper

Physical and Environmental Effects on the Energy Dissipating Characteristics of Balsa Wood

1966-02-01
660657
This paper presents the results of a developmental program designed to determine physical and environmental effects on the response of balsa wood as an energy dissipator. Specifically, the effects of moisture content, density, temperature, and pressure on the energy dissipating characteristics of balsa wood are presented. It is shown that the response of balsa wood is critically dependent on physical and environmental conditions, and that the energy dissipating capacity of the material increases significantly under certain combinations of these conditions.
Technical Paper

Planar Array REDOX Cells and pH Sensors for ISS Water Quality and Microbe Detection

2003-07-07
2003-01-2553
This paper describes results acquired from E-Tongue 2 and E-Tongue 3 which are arrays of planar three-element electrochemical cells and pH sensors. The approach uses ASV (Anodic Stripping Voltammery) to achieve a detection limit, which in the case of Pb, is below one μM which is needed for water quality measurements. The richness of the detectable species is illustrated with Fe where seven species are identified using the Pourbiax diagram. The detection of multiple species is illustrated using Pb and Cu. The apparatus was used to detect the electroactivity of the metabolic-surrogate, PMS (phenazine-methosulphate). Finally, four types of pH sensors were fabricated and characterized for linearity, sensitivity, and responsiveness.
Technical Paper

Propellant Expulsion in Unmanned Spacecraft

1964-01-01
640792
Bladders, diaphragms, and pistons used for the positive expulsion of earth-storable liquid rocket propellants are discussed in general terms. The history of PL's work on these devices is reviewed as a background to the current programs. A detailed account of the development and use of bladders in Ranger and Mariner spacecraft is presented. The final section describes an advanced development program aimed at providing technology for future spacecraft.
Technical Paper

Q-PCR Based Bioburden Assessment of Drinking Water Throughout Treatment and Delivery to the International Space Station

2005-07-11
2005-01-2932
Previous studies indicated evidence of opportunistic pathogens in samples obtained during missions to the International Space Station (ISS). This study utilized TaqMan quantitative PCR to determine specific gene abundance in potable and non-potable ISS waters. Probe and primer sets specific to the small subunit rRNA genes were designed and used to elucidate overall bacterial rRNA gene numbers. In addition, primer-probe sets specific for Burkholderia cepacia and Stenotrophomonas maltophilia were optimized and genes of these two opportunistic pathogens quantified in the pre- and post-flight drinking water as well as coolant waters. This Q-PCR approach supports findings of previous culture-based studies however; the culture based studies may have underestimated the microbial burden of ISS drinking water.
Technical Paper

Results from the Vehicle Cabin Atmosphere Monitor: A Miniature Gas Chromatograph/Mass Spectrometer for Trace Contamination Monitoring on the ISS and Orion

2008-01-29
2008-01-2045
Progress on the delivery of the Vehicle Cabin Atmosphere Monitor (VCAM) is reported. VCAM is an autonomous trace-species detector to be used aboard the International Space Station (ISS) for atmospheric analysis. The instrument is based on a low-mass, low-power miniature preconcentrator, gas chromatograph, and Paul ion trap mass spectrometer (PCGC/MS) capable of measuring volatile constituents in a space vehicle or planetary outpost at sub-ppm levels. VCAM detects and quantifies 40 target compounds at their 180-day Spacecraft Maximum Allowable Concentration (SMAC) levels. It is designed to operate autonomously, maintenance-free, with a self-contained carrier and calibration gas supplies sufficient for a one-year lifetime. Two flight units will be delivered for operation in the ISS EXPRESS rack.
Technical Paper

Self-Deployable Foam Antenna Structures for Earth Observation Radiometer Applications

2006-07-17
2006-01-2064
The overall goal of this program was the development of a 10 m. diameter, self-deployable antenna based on an open-celled rigid polyurethane foam system. Advantages of such a system relative to current inflatable or self-deploying systems include high volumetric efficiency of packing, high restoring force, low (or no) outgassing, low thermal conductivity, high dynamic damping, mechanical isotropy, infinite shelf life, and easy fabrication with methods amenable to construction of large structures (i.e., spraying). As part of a NASA Phase II SBIR, Adherent Technologies and its research partners, Temeku Technologies, and NASA JPL/Caltech, conducted activities in foam formulation, interdisciplinary analysis, and RF testing to assess the viability of using open cell polyurethane foams for self-deploying antenna applications.