Refine Your Search

Topic

Search Results

Standard

Ambulance Equipment Mount Device or Systems

2014-07-14
CURRENT
J3043_201407
Its purpose is to provide equipment manufacturers, ambulance builders, and end-users with testing procedures and, where appropriate, acceptance criteria that, to a great extent, ensure equipment mount devices or systems meet the same performance criteria across the industry.
Standard

Ambulance Interior Storage Compartment Integrity

2022-06-21
CURRENT
J3058_202206
Its purpose is to provide component manufacturers, ambulance builders, and end-users with testing procedures and, where appropriate, acceptance criteria that, to a great extent, ensure interior Storage Compartments or systems meet the same performance criteria across the industry.
Standard

Ambulance Litter Integrity, Retention, and Patient Restraint

2022-06-21
CURRENT
J3027_202206
Its purpose is to provide litter manufacturers, ambulance builders, and end-users with testing procedures and, where appropriate, acceptance criteria that, to a great extent ensures the patient litter, litter retention system, and patient restraint utilizes a similar dynamic performance test methodology to that which is applied to other vehicle seating and occupant restraint systems.
Standard

Ambulance Modular Body Evaluation - Quasi-Static Loading for Type I and Type III Modular Ambulance Bodies

2023-02-06
CURRENT
J3057_202302
This SAE Recommended Practice describes the test procedures for conducting quasi-static modular body strength tests for ambulance applications. Its purpose is to establish recommended test practices which standardize the procedure for Type I and Type III bodies, provide ambulance builders and end-users with testing procedures and, where appropriate, provide acceptance criteria that, to a great extent, ensures the ambulance structure meets the same performance criteria across the industry. ...Its purpose is to establish recommended test practices which standardize the procedure for Type I and Type III bodies, provide ambulance builders and end-users with testing procedures and, where appropriate, provide acceptance criteria that, to a great extent, ensures the ambulance structure meets the same performance criteria across the industry. ...Its purpose is to establish recommended test practices which standardize the procedure for Type I and Type III bodies, provide ambulance builders and end-users with testing procedures and, where appropriate, provide acceptance criteria that, to a great extent, ensures the ambulance structure meets the same performance criteria across the industry. Descriptions of the test set-up, test instrumentation, photographic/video coverage, and the test fixtures are included.
Standard

Ambulance Patient Compartment Seating Integrity and Occupant Restraint

2016-11-01
CURRENT
J3026_201611
Its purpose is to provide ambulance seating manufacturers, ambulance occupant restraint manufacturers, ambulance builders, and end-users with testing procedures and, where appropriate, acceptance criteria that, to a great extent ensures the occupant seating and occupant restraint system meet similar performance criteria as FMVSS 208 requires for seat belted passengers in light vehicles. ...This SAE Recommended Practice describes the testing procedures that may be used to evaluate the integrity of ground ambulance-based occupant seating and occupant restraint systems for workers and civilians transported in the patient compartment of an ambulance when exposed to a frontal or side impact. This Recommended Practice was based on ambulance patient compartment dynamics and is not applicable to other vehicle applications or seating positions.
Standard

Ambulance Patient Compartment Seated Occupant Excursion Zone Evaluation

2024-01-19
CURRENT
J3059_202401
This SAE Information Report describes the testing and reporting procedures that may be used to evaluate and document the excursion of a worker or civilian when transported in a seated and restrained position in the patient compartment of a ground ambulance when exposed to a front, side, or rear impact. Its purpose is to provide seating and occupant restraint manufacturers, ambulance builders, and end-users with testing procedures and documentation methods needed to identify head travel paths in crash loading events. ...Its purpose is to provide seating and occupant restraint manufacturers, ambulance builders, and end-users with testing procedures and documentation methods needed to identify head travel paths in crash loading events. ...Rather, the goal is to provide ambulance manufacturers with the data needed to design safer and functionally sound workstations for Emergency Medical Service workers so that workers are better able to safely perform patient care tasks in a moving ambulance.
Standard

Ambulance Patient Compartment Structural Integrity Test to Support SAE J3027 Compliant Litter Systems

2022-06-21
CURRENT
J3102_202206
This SAE Recommended Practice describes the dynamic and static testing procedures required to evaluate the integrity of the ambulance substructure, to support the safe mounting of an SAE J3027 compliant litter retention device or system, when exposed to a frontal, side or rear impact (i.e., a crash impact). ...Its purpose is to provide manufacturers, ambulance builders, and end-users with testing procedures and, where appropriate, acceptance criteria that to a great extent ensure the ambulance substructure meets the same performance criteria across the industry. ...Its purpose is to provide manufacturers, ambulance builders, and end-users with testing procedures and, where appropriate, acceptance criteria that to a great extent ensure the ambulance substructure meets the same performance criteria across the industry. Prospective manufacturers or vendors have the option of performing either dynamic testing or static testing.
Standard

Occupant Restraint and Equipment Mounting Integrity – Side Impact Ambulance Patient Compartment

2022-06-20
CURRENT
J2956_202206
This SAE Recommended Practice describes the test procedures for conducting side impact occupant restraint and equipment mounting integrity tests for ambulance patient compartment applications. Its purpose is to describe crash pulse characteristics and establish recommended test procedures that will standardize restraint system and equipment mounting testing for ambulances. ...Its purpose is to describe crash pulse characteristics and establish recommended test procedures that will standardize restraint system and equipment mounting testing for ambulances. Descriptions of the test set-up, test instrumentation, photographic/video coverage, and the test fixtures are included.
Standard

Occupant Restraint and Equipment Mounting Integrity – Frontal Impact Ambulance Patient Compartment

2022-06-20
CURRENT
J2917_202206
This SAE Recommended Practice describes the test procedures for conducting frontal impact occupant restraint and equipment mounting integrity tests for ambulance patient compartment applications. Its purpose is to describe crash pulse characteristics and establish recommended test procedures that will standardize restraint system and equipment mounting testing for ambulances. ...Its purpose is to describe crash pulse characteristics and establish recommended test procedures that will standardize restraint system and equipment mounting testing for ambulances. Descriptions of the test set-up, test instrumentation, photographic/video coverage, and the test fixtures are included.
Standard

Occupant Restraint and Equipment Mounting Integrity - Rear Impact Ambulance Patient Compartment

2022-06-21
CURRENT
J3044_202206
This SAE Recommended Practice describes the test procedures for conducting rear impact occupant restraint and equipment mounting integrity tests for ambulance patient compartment applications. Its purpose is to describe crash pulse characteristics and establish recommended test procedures that will standardize restraint system and equipment mount testing for ambulances. ...Its purpose is to describe crash pulse characteristics and establish recommended test procedures that will standardize restraint system and equipment mount testing for ambulances. Descriptions of the test set-up, test instrumentation, photographic/video coverage, and the test fixtures are included.
Technical Paper

Crash Testing of Ambulance Chassis Cab Vehicles

2007-10-30
2007-01-4267
This program consisted of testing one Type I ambulance mounted on a Ford F-350 truck chassis (1994 vintage), and three Type III ambulances mounted on Ford E-350 van chassis (two 1993, and one 1999 vintage). ...Army Tank-Automotive and Armaments Command (TACOM), and the Ministry of Health & Long-Term Care, Ontario (Canada), conducted a test program to evaluate the capability of mobile restraint systems to protect occupants in the patient compartment of an ambulance. This paper focuses on the vehicle chassis behavior and acceleration pulses as seen in each test conducted to support the program. ...A vehicle-to-vehicle side impact test was conducted using the Type I ambulance with a targeted change in velocity of 27.4 kph (17 mph). A 1984 Chevrolet Sierra 2500 was the impacting vehicle for the side test.
Journal Article

Ambulance Vehicle Crashworthiness and Passive Safety Design: A Comparative Evaluation

2008-10-07
2008-01-2695
This comparative evaluation of USA ‘concept safety’ ambulances and a standard Australian ambulance is based on basic principles of crashworthiness and available crash test data. ...Ambulances are largely exempt from crashworthiness and occupant protection passive safety design standards in the USA, and have a poor road safety record. ...There are features of USA ambulance design that are not within known principles and technical aspects of crashworthiness and safety design, and include some predictable serious occupant protection hazards.
Standard

Ambulance Interior Storage Compartment Integrity

2016-11-01
HISTORICAL
J3058_201611
Its purpose is to provide component manufacturers, ambulance builders, and end-users with testing procedures and, where appropriate, acceptance criteria that, to a great extent, ensure interior Storage Compartments or systems meet the same performance criteria across the industry.
Standard

Ambulance Patient Compartment Seating Integrity and Occupant Restraint

2014-08-11
HISTORICAL
J3026_201408
Its purpose is to provide ambulance seating manufacturers, ambulance occupant restraint manufacturers, ambulance builders, and end-users with testing procedures and, where appropriate, acceptance criteria that, to a great extent ensures the occupant seating and occupant restraint system meet similar performance criteria as FMVSS 208 requires for seat belted passengers in light vehicles. ...This SAE Recommended Practice describes the testing procedures that may be used to evaluate the integrity of ground ambulance-based occupant seating and occupant restraint systems for workers and civilians transported in the patient compartment of an ambulance when exposed to a frontal or side impact. This Recommended Practice was based on ambulance patient compartment dynamics and is not applicable to other vehicle applications or seating positions.
Standard

Ambulance Litter Integrity, Retention, and Patient Restraint

2016-11-01
HISTORICAL
J3027_201611
Its purpose is to provide litter manufacturers, ambulance builders, and end-users with testing procedures and, where appropriate, acceptance criteria that, to a great extent ensures the patient litter, litter retention system, and patient restraint utilizes a similar dynamic performance test methodology to that which is applied to other vehicle seating and occupant restraint systems.
Standard

Ambulance Litter Integrity, Retention, and Patient Restraint

2014-07-14
HISTORICAL
J3027_201407
Its purpose is to provide litter manufacturers, ambulance builders, and end-users with testing procedures and, where appropriate, acceptance criteria that, to a great extent ensures the patient litter, litter retention system, and patient restraint utilizes a similar dynamic performance test methodology to that which is applied to other vehicle seating and occupant restraint systems.
Standard

Ambulance Modular Body Evaluation-Quasi-Static Loading for Type I and Type III Modular Ambulance Bodies

2017-02-22
HISTORICAL
J3057_201702
This SAE Recommended Practice describes the test procedures for conducting quasi-static modular body strength tests for ambulance applications. Its purpose is to establish recommended test practices which standardize the procedure for Type I and Type III bodies, provide ambulance builders and end-users with testing procedures and, where appropriate, provide acceptance criteria that, to a great extent, ensures the ambulance structure meets the same performance criteria across the industry. ...Its purpose is to establish recommended test practices which standardize the procedure for Type I and Type III bodies, provide ambulance builders and end-users with testing procedures and, where appropriate, provide acceptance criteria that, to a great extent, ensures the ambulance structure meets the same performance criteria across the industry. ...Its purpose is to establish recommended test practices which standardize the procedure for Type I and Type III bodies, provide ambulance builders and end-users with testing procedures and, where appropriate, provide acceptance criteria that, to a great extent, ensures the ambulance structure meets the same performance criteria across the industry. Descriptions of the test set-up, test instrumentation, photographic/video coverage, and the test fixtures are included.
Standard

Ambulance Patient Compartment Seated Occupant Excursion Zone Evaluation

2017-04-06
HISTORICAL
J3059_201704
This SAE Information Report describes the testing and reporting procedures that may be used to evaluate and document the excursion of a worker or civilian when transported in a seated and restrained position in the patient compartment of a ground ambulance when exposed to a front, side, or rear impact. Its purpose is to provide seating and occupant restraint manufacturers, ambulance builders, and end-users with testing procedures and documentation methods needed to identify head travel paths in crash loading events. ...Its purpose is to provide seating and occupant restraint manufacturers, ambulance builders, and end-users with testing procedures and documentation methods needed to identify head travel paths in crash loading events. ...Rather, the goal is to provide ambulance manufacturers with the data needed to design safer and functionally sound workstations for Emergency Medical Service workers so that workers are better able to safely perform patient care tasks in a moving ambulance.
Standard

Ambulance Patient Compartment Structural Integrity Test to Support SAE J3027 Compliant Litter Systems

2017-03-28
HISTORICAL
J3102_201703
This SAE Recommended Practice describes the dynamic and static testing procedures required to evaluate the integrity of the ambulance substructure, to support the safe mounting of an SAE J3027 compliant litter retention device or system, when exposed to a frontal, side or rear impact (i.e., a crash impact). ...Its purpose is to provide manufacturers, ambulance builders, and end-users with testing procedures and, where appropriate, acceptance criteria that to a great extent ensure the ambulance substructure meets the same performance criteria across the industry. ...Its purpose is to provide manufacturers, ambulance builders, and end-users with testing procedures and, where appropriate, acceptance criteria that to a great extent ensure the ambulance substructure meets the same performance criteria across the industry. Prospective manufacturers or vendors have the option of performing either dynamic testing or static testing.