Refine Your Search

Search Results

Technical Paper

Development of an Unbiased Validation Protocol to Assess the Biofidelity of Finite Element Head Models used in Prediction of Traumatic Brain Injury

2016-11-07
2016-22-0013
This study describes a method to identify laboratory test procedures and impact response requirements suitable for assessing the biofidelity of finite element head models used in prediction of traumatic brain injury. The selection of the experimental data and the response requirements were result of a critical evaluation based on the accuracy, reproducibility and relevance of the available experimental data. A weighted averaging procedure was chosen in order to consider different contributions from the various test conditions and target measurements based on experimental error. According to the quality criteria, 40 experimental cases were selected to be a representative dataset for validation. Based on the evaluation of response curves from four head finite element models, CORA was chosen as a quantitative method to compare the predicted time history response to the measured data.