Refine Your Search

Search Results

Viewing 1 to 10 of 10
Technical Paper

Development of a New Ejector Performance Map for Design of an Automotive Air Conditioning System

2020-04-14
2020-01-1244
Ejector as a work recovery device offers potential for developing energy efficient heating and cooling systems based on vapor compression technology. For applications like automobile air conditioning, the operating conditions vary significantly which can lead to considerable performance degradation when the system is operated in off-design conditions. Therefore, system designing warrants development of accurate ejector performance models for a wide range of operating conditions. In this paper, a novel methodology for ejector performance maps is proposed using ejector efficiency as performance parameter and volumetric entrainment ratio as characterization parameter. The proposed performance map is developed after conducting experiments to find appropriate performance representation where ejector driven flow can be characterized using ejector motive flow. The developed performance map can predict ejector pressure lift within an accuracy of 20% using an iterative solver.
Technical Paper

Sound Evaluation of Flow-Induced Noise with Simultaneous Measurement of Flow Regimes at TXV Inlet of Automotive Evaporators

2020-04-14
2020-01-1255
In the air conditioning system, flow-induced noise is very disturbing, including the noise generated in the expansion device and the heat exchangers. In the past few decades, most researches related to flow-induced noise focused on the relationship between the flow regimes near the expansion device and the amplitude of flow-induced noise when the measurements are not synched. In this paper, an experimental approach is used to explore the simultaneous relationships between flow-induced noise characteristics and flow regimes at the inlet of TXV of evaporators used in automobiles. A pumped R134a loop with microphones and transparent visualization sections is used to simulate the vapor compression system. Also, the paper evaluates the severity of flow-induced noise from not only the amplitude of noise but also the frequency of noise with a parameter called psychoacoustic annoyance (PA).
Technical Paper

Analysis of the Spray Numerical Injection Modeling for Gasoline Applications

2020-04-14
2020-01-0330
The modeling of fuel jet atomization is key in the characterization of Internal Combustion (IC) engines, and 3D Computational Fluid Dynamics (CFD) is a recognized tool to provide insights for design and control purposes. Multi-hole injectors with counter-bored nozzle are the standard for Gasoline Direct Injection (GDI) applications and the Spray-G injector from the Engine Combustion Network (ECN) is considered the reference for numerical studies, thanks to the availability of extensive experimental data. In this work, the behavior of the Spray-G injector is simulated in a constant volume chamber, ranging from sub-cooled (nominal G) to flashing conditions (G2), validating the models on Diffused Back Illumination and Phase Doppler Anemometry data collected in vaporizing inert conditions.
Technical Paper

NOx Reduction in Compression-Ignition Engine by Inverted Ignition Phi-Sensitivity

2017-03-28
2017-01-0749
A new approach of NOx reduction in the compression-ignition engine is introduced in this work. The previous research has shown that during the combustion stage, the high temperature ignition tends to occur early at the near-stoichiometric region where the combustion temperature is high and majority of NOx is formed; Therefore, it is desirable to burn the leaner region first and then the near-stoichiometric region, which inhibits the temperature rise of the near-stoichiometric region and consequently suppresses the formation of NOx. Such inverted ignition sequence requires mixture with inverted phi-sensitivity. Fuel selection is performed based on the criteria of strong ignition T-sensitivity, negligible negative temperature coefficient (NTC) behavior, and large heat of vaporization (HoV).
Journal Article

Modeling of a Reversible Air Conditioning-Heat Pump System for Electric Vehicles

2016-04-05
2016-01-0261
This paper presents a simulation model for a reversible air conditioning and heat pump system for electric vehicles. The system contains a variable speed compressor, three microchannel heat exchangers, an accumulator, and two electronic expansion valves. Heat exchangers are solved by discretizing into cells. Compressor and accumulator models are developed by fitting data with physical insights. Expansion valves are modeled by isenthalpic processes. System performance is calculated by connecting all parts in the same way as the physical system and solved iteratively. The model is reasonably validated against experimental data from a separate experimental study. Future improvement is needed to take into account maldistribution in outdoor heat exchanger working as an evaporator in HP mode. Charge retention in components also requires further study.
Technical Paper

Refrigerant-Oil Flow at the Compressor Discharge

2016-04-05
2016-01-0247
Automotive air conditioning compressor produces an annular-mist flow consisting of gas-phase refrigerant flow with oil film and oil droplets. This paper reports a method to calculate the oil retention and oil circulation ratio based on oil film thickness, wave speed, oil droplet size, oil droplet speed, and mass flow rate. Oil flow parameters are measured by high-speed camera capture and video processing in a non-invasive way. The estimated oil retention and oil circulation ratio results are compared quantitatively with the measurements from system experiments under different compressor outlet gas superficial velocity. The agreement between video result and sampling measurement shows that this method can be applied in other annular-mist flow analysis. It is also shown that most of the oil exists in film from the mass point of view while oil droplets contributes more to the oil mass flow rate because they travel in a much higher speed.
Technical Paper

Numerical Investigation of the Effect of Microchannel Evaporator Design on the Performance of Two-Phase Ejector Automotive Air Conditioning Cycles

2015-04-14
2015-01-0362
Much attention has been given in recent years to the use of two-phase ejectors and particularly to the performance of the standard ejector cycle with a liquid-vapor separator. However, this cycle may not be the best choice for automotive applications due to the large size required by an efficient separator as well as the cycle's performance at conditions of lower ejector potential. A limited amount of recent research has focused on alternate two-phase ejector cycles that may be better suited for automotive applications. One of these cycles, using the ejector to allow for evaporation at two different temperatures and eliminating the need for a separator, will be the subject of investigation in this paper. Previous investigations of this cycle have been mainly theoretical or experimental; this paper aims to provide a numerical analysis of the effect of evaporator design on the performance of the ejector cycles.
Journal Article

An Experimentally Validated Model for Predicting Refrigerant and Lubricant Inventory in MAC Heat Exchangers

2014-04-01
2014-01-0694
The paper presents a semi-empirical model to predict refrigerant and lubricant inventory in both evaporator and condenser of an automotive air conditioning (MAC) system. In the model, heat exchanger is discretized into small volumes. Temperature, pressure and mass inventory are calculated by applying heat transfer, pressure drop and void fraction correlations to these volumes respectively. Refrigerant and lubricant are treated as a zeotropic mixture with a temperature glide. As refrigerant evaporates or condenses, thermophysical properties are evaluated accordingly with the change of lubricant concentration. Experimental data is used to validate the model. As a result, refrigerant and lubricant mass is predicted within 20% in the evaporator. However, in the condenser, lubricant mass was consistently under-predicted while refrigerant mass was predicted within 15% error. Moreover, the lubricant under-prediction becomes more significant at higher Oil Circulation Ratio (OCR).
Technical Paper

Numerical study on wall film formation and evaporation

2014-04-01
2014-01-1112
The numerical models presented in this study are established based on discrete phase model (DPM) of spray dispersion and evaporation considering the cold wall operating condition of port injection system. All the models were implemented into the CFD software FLUENT. Gas flow and film flow and spray are coupled by mass, momentum and energy transfer due to spray impingement, film evaporation and surface shear stress. Influences of impact parameters including injection height, injection duration and injection angle on the formation and evaporation of wall-film are discussed. The results show that, with the increase of injection height, the maximum film thickness and wall film ratio decrease, and fuel vapor mass ratio increases. The reductions of film thickness and wall film ratio are not obvious as the increasing of injection height. Extending the injection duration could add the maximum film thickness and film area.
Technical Paper

Comparison of CO2 and R134a Two-Phase Ejector Performance for Use in Automotive Air Conditioning Applications

2014-04-01
2014-01-0689
Two-phase ejectors are devices capable of recovering the expansion power that is lost by the throttling process in air conditioning cycles, resulting in improved system performance. High-pressure fluids such as CO2 have received the majority of attention in two-phase ejector studies in recent years due to the fluid's high throttling loss and high potential for improvement. However, low-pressure working fluids such as R134a, commonly used in automotive applications, have received considerably less attention owing to their lower recovery potential. While the two fluids have very different properties, both offer the potential for noticeable COP improvement with ejector cycles. Thus, understanding the operation and performance of ejectors with both fluids can be important to the design of ejector air conditioning cycles. This paper compares available experimental data for the performance of two-phase ejectors using CO2 and R134a.
X