Technical Paper

ISS IATCS Coolant Loop Biocide Implementation

2008-06-29
2008-01-2159
The proliferation and growth of microorganisms in the Internal Active Thermal Control System (IATCS) aboard the International Space Station (ISS) has been of significant concern since 2001. Initial testing and assessments of biocides to determine bacterial disinfection capability, material compatibility, stability (rate of oxidative degradation and identification of degradation products), solubility, application methodology, impact on coolant toxicity hazard level, and impact on environmental control and life support systems identified a prioritized list of acceptable biocidal agents including glutaraldehyde, ortho-phthalaldehyde (OPA), and methyl isothiazolone. Glutaraldehyde at greater than 25 ppm was eliminated due to NASA concerns with safety and toxicity and methyl isothiazolone was eliminated from further consideration due to ineffectiveness against biofilms and toxicity at higher concentrations.
Technical Paper

Liquid Cooling Garment Adaptation to Enhance Surgical Outcomes

2003-07-07
2003-01-2339
Hypothermia is a well documented problem for surgical patients and is historically addressed by the use of a variety of warming aids and devices applied to the patient before, during, and after surgery. Their effectiveness is limited in many surgeries by practical constraints of surgical access, and hypothermia remains a significant concern. Increasing the temperature of the operating room has been proposed as an alternative solution. However, operating room temperatures must be cool enough to limit thermal stress on the surgical team despite the heat transport barriers imposed by protective sterile garments. Space technology in the form of the liquid cooling garment worn by EVA astronauts answers this need. Hamilton Sundstrand Space Systems International (HSSSI) has been working with Hartford Hospital to adapt liquid cooling garment technology for use by surgical teams in order to allow them to work comfortably in warmer operating room environments.
Technical Paper

Chameleon Suit – A Different Paradigm for Future EVA Systems

2003-07-07
2003-01-2445
The demands of future NASA exploration and scientific missions in space force the reevaluation of some of the basic assumptions and approaches that underlie current extravehicular activity (EVA) systems. Developing designs that can simultaneously achieve the advanced capabilities and the reductions in system mass and mission expendables targeted by NASA has proven to be a formidable challenge. The constraints of human needs, space environments, and current EVA system architectures demand technical capabilities beyond current expectations to achieve system goals. Under NASA Institute for Advanced Concepts (NIAC) sponsorship, Hamilton Sundstrand has been studying a new system paradigm to achieve the EVA system goals. The Chameleon Suit concept employs an active pressure suit that directly interacts between human systems and space environments.
Technical Paper

Performance Characteristics of a High Intensity Cryogenic Flow Boiler

2003-07-07
2003-01-2507
Hamilton Sundstrand has been working on the development of a new cryogenic flow boiler based on its patented compact, high-intensity cooler (CHIC) technology intended to provide low weight and volume and overcome freezing problems associated with cryogen use in EVA spacesuit cooling. Tests of the prototype device resulting from that effort have now been completed. The test data demonstrate that the design is extremely resistant to freezing the heat transport fluid as anticipated. Highly effective heat transfer is achieved in a compact device combining the functions of several conventional heat exchangers. This novel heat exchanger, a “normal flow” layered impingement arrangement should provide a very compact solution to any heat transfer applications where the cold fluid operates below the warm fluid's freezing point. Test results are generally consistent with design analyses for the prototype.
Technical Paper

Selection of an Alternate Biocide for the International Space Station Internal Active Thermal Control System Coolant Loops

2003-07-07
2003-01-2568
The International Space Station (ISS) IATCS (Internal Active Thermal Control System) includes two internal coolant loops that use an aqueous based coolant for heat transfer. A silver salt biocide was used initially as an additive in the coolant formulation to control the growth and proliferation of microorganisms in the coolant loops. Ground-based and in-flight testing has demonstrated that the silver salt is rapidly depleted and not effective as a long-term biocide. Efforts are now underway to select an alternate biocide for the IATCS coolant loop with greatly improved performance. An extensive evaluation of biocides was conducted to select several candidates for test trials.
Technical Paper

Development, Testing, and Packaging of a Redundant Regenerable Carbon Dioxide Removal System (RRCRS)

2002-07-15
2002-01-2530
Enhancements to the Regenerable Carbon Dioxide Removal System (RCRS) have undergone full-scale, pre-prototype development and testing to demonstrate a redundant system within the volume allotted for the RCRS on the Space Shuttle Orbiter. The concept for a Redundant Regenerable Carbon Dioxide Removal System (RRCRS) utilizes the existing canister of the RCRS, but partitions it into two, independent, two-bed systems. This partitioning allows for two, fully capable RCRS units to be packaged within the original volume, thus reducing stowage volume and launch weight when compared to the flight RCRS plus the backup LiOH system. This paper presents the results of development and testing of a full-scale, pre-prototype RRCRS and includes an overview of the design concept for a redundant system that can be packaged within the existing envelope.
Technical Paper

Multi-Purpose Logistics Module (MPLM) Cargo Heat Exchanger

2002-07-15
2002-01-2415
This paper describes the New Shuttle Orbiter's Multi-Purpose Logistics Module (MPLM) Cargo Heat Exchanger (HX) and associated MPLM cooling system. Heat Exchanger (HX) design and system performance characteristics of the system are presented.
Technical Paper

An Improved Pyrolyzer for Solid Waste Resource Recovery in Space

2002-07-15
2002-01-2402
Pyrolysis processing is one of several options for solid waste resource recovery in space. It has the advantage of being relatively simple and adaptable to a wide variety of feedstocks and it can produce several usable products from typical waste streams. The overall objective of this study was to produce a prototype mixed solid waste pyrolyzer for spacecraft applications. A two-stage reactor system was developed which can process a maximum of about 0.5 kg of waste per cycle. The reactor includes a pyrolysis chamber where the waste is heated to temperatures above 600 °C for primary pyrolysis. The volatile products (liquids, gases) are transported by a N2 purge gas to a second chamber which contains a catalyst bed for cracking the tars at temperatures of about 1000-1100 °C. The tars are cracked into carbon and additional gases. Most of the deposited carbon is subsequently gasified by oxygenated volatiles (CO2, H2O) from the first stage.
Technical Paper

Rotary Drum Separator and Pump for the Sabatier Carbon Dioxide Reduction System

2005-07-11
2005-01-2863
A trade study conducted in 2001 selected a rotary disk separator as the best candidate to meet the requirements for an International Space Station (ISS) Carbon Dioxide Reduction Assembly (CRA). The selected technology must provide micro-gravity gas/liquid separation and pump the liquid from 69 kPa (10 psia) at the gas/liquid interface to 124 kPa (18 psia) at the wastewater bus storage tank. The rotary disk concept, which has pedigree in other systems currently being built for installation on the ISS, failed to achieve the required pumping head within the allotted power. The separator discussed in this paper is a new design that was tested to determine compliance with performance requirements in the CRA. The drum separator and pump (DSP) design is similar to the Oxygen Generator Assembly (OGA) Rotary Separator Accumulator (RSA) in that it has a rotating assembly inside a stationary housing driven by a integral internal motor[1].
Technical Paper

Assessment of Technology Readiness Level of a Carbon Dioxide Reduction Assembly (CRA) for Use on International Space Station

2004-07-19
2004-01-2446
When technologies are traded for incorporation into vehicle systems to support a specific mission scenario, they are often assessed in terms of “Technology Readiness Level” (TRL). TRL is based on three major categories of Core Technology Components, Ancillary Hardware and System Maturity, and Control and Control Integration. This paper describes the Technology Readiness Level assessment of the Carbon Dioxide Reduction Assembly (CRA) for use on the International Space Station. A team comprising of the NASA Johnson Space Center, Marshall Space Flight Center, Southwest Research Institute and Hamilton Sundstrand Space Systems International have been working on various aspects of the CRA to bring its TRL from 4/5 up to 6. This paper describes the work currently being done in the three major categories. Specific details are given on technology development of the Core Technology Components including the reactor, phase separator and CO2 compressor.
Technical Paper

Selection of an Alternate Biocide for the ISS Internal Thermal Control System Coolant - Phase II

2004-07-19
2004-01-2472
The ISS (International Space Station) ITCS (Internal Thermal Control System) includes two internal coolant loops that utilize an aqueous based coolant for heat transfer. A silver salt biocide had previously been utilized as an additive in the coolant formulation to control the growth and proliferation of microorganisms within the coolant loops. Ground-based and in-flight testing demonstrated that the silver salt was rapidly depleted, and did not act as an effective long-term biocide. Efforts to select an optimal alternate biocide for the ITCS coolant application have been underway and are now in the final stages. An extensive evaluation of biocides was conducted to down-select to several candidates for test trials and was reported on previously.