Refine Your Search

Search Results

Viewing 1 to 6 of 6
Journal Article

A Work-Based Window Method for Calculating In-Use Brake-Specific NOx Emissions of Heavy-Duty Diesel Engines

2008-04-14
2008-01-1301
A work-based window method has been developed to calculate in-use brake-specific oxides of nitrogen (NOx) emissions for all engine speeds and engine loads. During an in-use test, engine speed and engine torque are read from the engine's electronic control unit, and along with time, are used to determine instantaneous engine power. Instantaneous work is calculated using this power and the time differential in the data collection. Work is then summed until the target amount of work is accumulated. The emissions levels are then calculated for that window of work. It was determined that a work window equal to the theoretical Federal Test Procedure (FTP) cycle work best provides a means of comparison to the FTP certification standard. Also, a failure criterion has been established based on the average amount of power generated in the work window and the amount of time required to achieve the target work window to determine if a particular work window is valid.
Technical Paper

Measurement of Brake-specific NOX Emissions using Zirconia Sensors for In-use, On-board Heavy-duty Vehicle Applications

2002-05-06
2002-01-1755
Emissions tests for heavy -duty diesel-fueled engines and vehicles are normally performed using engine dynamometers and chassis dynamometers, respectively, with laboratory grade gaseous concentration measurement analyzers and supporting test equipment. However, a considerable effort has been recently expended on developing in-use, on-board tools to measure brake-specific emissions from heavy -duty vehicles with the highest degree of accuracy and precision. This alternative testing methodology would supplement the emissions data that is collected from engine and chassis dynamometer tests. The on-board emissions testing methodology entails actively recording emissions and vehicle operating parameters (engine speed and load, vehicle speed etc.) from vehicles while they are operating on the road. This paper focuses on in-use measurements of NOX with zirconium oxide sensors and other portable NOX detectors.
Technical Paper

Measurement of In-Use, On-Board Emissions from Heavy-Duty Diesel Vehicles:Mobile Emissions Measurement System

2001-09-24
2001-01-3643
Emissions tests for heavy-duty diesel-fueled vehicles are normally performed using an engine dynamometer or a chassis dynamometer. Both of these methods generally entail the use of laboratory-grade emissions measurement instrumentation, a CVS system, an environment control system, a dynamometer, and associated data acquisition and control systems. The results obtained from such tests provide a means by which engines may be compared to the emissions standards, but may not be truly indicative of an engine's in-vehicle performance while operating on the road. An alternative to such a testing methodology would be to actively record the emissions from a vehicle while it was operating on-road. A considerable amount of discussion has been focused on the development of on-road emissions measurement systems (OREMS) that would provide for such in-use emissions data collection.
Technical Paper

Comparison of Particulate Matter Emissions from Different Aftertreatment Technologies in a Wind Tunnel

2013-09-08
2013-24-0175
Stringent emission regulations have forced drastic technological improvements in diesel after treatment systems, particularly in reducing Particulate Matter (PM) emissions. Those improvements generally regard the use of Diesel Oxidation Catalyst (DOC), Diesel Particulate Filter (DPF) and lately also the use of Selective Catalyst Reduction (SCR) systems along with improved engine control strategies for reduction of NOx emissions from these engines. Studies that have led to these technological advancements were made in controlled laboratory environment and are not representative of real world emissions from these engines or vehicles. In addition, formation and evolution of PM from these engines are extremely sensitive to overall changes in the dilution process.
Technical Paper

Design of a Portable Micro-Dilution Tunnel Particulate Matter Emissions Measurement System

2005-10-24
2005-01-3795
The Federal Test Procedure (FTP) for heavy-duty engines requires the use of a full-flow tunnel based constant volume sampler (CVS). These are costly to build and maintain, and require a large workspace. A small portable micro-dilution system that could be used on-board, for measuring emissions of in-use, heavy-duty vehicles would be an inexpensive alternative. This paper presents the rationale behind the design of such a portable particulate matter measuring system. The presented micro-dilution tunnel operates on the same principle as a full-flow tunnel, however given the reduced size dilution ratios can be more easily controlled with the micro dilution system. The design targets dilution ratios of at least four to one, in accordance with the ISO 8178 requirements. The unique features of the micro-dilution system are the use of only a single pump and a porous sintered stainless steel tube for mixing dilution air and raw exhaust sample.
Technical Paper

Evaluation of a Portable Micro-Dilution Tunnel Particulate Measurement System

2005-10-24
2005-01-3789
The Federal Test Procedure (FTP) for heavy-duty engines requires the use of a full-flow tunnel based constant volume sampler (CVS) which is costly to build and maintain, and requires a large workspace. A portable micro-dilution system that could be used for measuring on-board, in use emissions from heavy duty vehicles would be an inexpensive alternative compared to a full-flow CVS tunnel, as well as requiring significantly less workspace. This paper evaluates such a portable particulate matter measuring system. This micro-dilution tunnel operates on the same principle as a full-flow tunnel, however dilution ratios can be more easily controlled with the micro dilution system. The dilution ratios for the micro-dilution system were maintained at least four to one, as per ISO 8178 requirements, by measuring the mass flow rates of the dilution air and dilute exhaust.
X