Refine Your Search

Search Results

Viewing 1 to 8 of 8
Technical Paper

Parametric Study of 2007 Standard Heavy-Duty Diesel Engine Particulate Matter Sampling System

2007-01-23
2007-01-0060
Heavy-Duty Diesel (HDD) engines' particulate matter (PM) emissions are most often measured quantitatively by weighing filters that collect diluted exhaust samples pre- and post-test. PM sampling systems that dilute exhaust gas and collect PM samples have different effects on measured PM data. Those effects usually contribute to inter-laboratory variance. The U.S. Environmental Protection Agency (EPA)'s 2007 PM emission measurement regulations for the test of HDD engines should reduce variability, but must also cope with PM mass that is an order of magnitude lower than legacy engine testing. To support the design of a 2007 US standard HDD PM emission sampling system, a parametric study based on a systematic Simulink® model was performed. This model acted as an auxiliary design tool when setting up a new 2007 HDD PM emission sampling system in a heavy-duty test cell at West Virginia University (WVU). It was also designed to provide assistance in post-test data processing.
Technical Paper

Nano Particulate Matter Evolution in a CFR1065 Dilution Tunnel

2009-11-02
2009-01-2672
Dual primary full-flow dilution tunnels represent an integral part of a heavy-duty transportable emissions measurement laboratory designed and constructed to comply with US Code of Federal Regulations (CFR) 40 Part 1065 requirements. Few data exist to characterize the evolution of particulate matter (PM) in full scale dilution tunnels, particularly at very low PM mass levels. Size distributions of ultra-fine particles in diesel exhaust from a naturally aspirated, 2.4 liter, 40 kW ISUZU C240 diesel engine equipped with a diesel particulate filter (DPF) were studied in one set of standard primary and secondary dilution tunnels with varied dilution ratios. Particle size distribution data, during steady-state engine operation, were collected using a Cambustion DMS500 Fast Particulate Spectrometer. Measurements were made at four positions that spanned the tunnel cross section after the mixing orifice plate for the primary dilution tunnel and at the outlet of the secondary dilution tunnel.
Technical Paper

Determination of In-Use Brake-Specific Emissions from Off-Road Equipment Powered by Mechanically Controlled Diesel Engines

2002-05-06
2002-01-1756
Exhaust emissions from off-highway diesel engines are a significant contributor of both oxides of nitrogen (NOx) and particulate matter (PM) to air inventories. Yet, emissions research activities aimed solely at the off-highway arena have been minimal - largely overshadowed by the extensive efforts directed toward the on-highway sector. However, with current trends indicating that the performance of these off-highway vehicles will become increasingly more scrutinized by federal regulatory agencies, augmentation of current research efforts will be necessary. The global objective for this study was to collect vehicle activity information for diesel-powered off-highway vehicles while they were operated in the field. Engine speed and raw exhaust CO2 concentrations were recorded and then used to create engine dynamometer test cycles. The engine was exercised according to these cycles in the laboratory so that the mass emissions rates of exhaust gas pollutants could be measured.
Technical Paper

Fresh and Aged SCRT Systems Retrofitted on a MY 1998 Class-8 Tractor: Investigation on In-use Emissions

2011-09-11
2011-24-0175
In order to comply with stringent 2010 US-Environmental Protection Agency (EPA) on-road, Heavy-Duty Diesel (HDD) emissions regulations, the Selective Catalytic Reduction (SCR) aftertreatment system has been judged by a multitude of engine manufacturers as the primary technology for mitigating emissions of oxides of nitrogen (NOx). As virtually stand-alone aftertreatment systems, SCR technology further represents a very flexible and efficient solution for retrofitting legacy diesel engines as the most straightforward means of cost-effective compliance attainment. However, the addition of a reducing agent injection system as well as the inherent operation limitations of the SCR system due to required catalyst bed temperatures introduce new, unique problems, most notably that of ammonia (NH₃) slip.
Technical Paper

Characteristics of Exhaust Emissions from a Heavy-Duty Diesel Engine Retrofitted to Operate in Methane/Diesel Dual-Fuel Mode

2013-09-08
2013-24-0181
The need for a cleaner and less expensive alternative energy source to conventional petroleum fuels for powering the transportation sector has gained increasing attention during the past decade. Special attention has been directed towards natural gas (NG) which has proven to be a viable option due to its clean-burning properties, reduced cost and abundant availability, and therefore, lead to a steady increase in the worldwide vehicle population operated with NG. The heavy-duty vehicle sector has seen the introduction of natural gas first in larger, locally operated fleets, such as transit buses or refuse-haulers. However, with increasing expansion of the NG distribution network more drayage and long-haul fleets are beginning to adopt natural gas as a fuel.
Technical Paper

Comparison of Particulate Matter Emissions from Different Aftertreatment Technologies in a Wind Tunnel

2013-09-08
2013-24-0175
Stringent emission regulations have forced drastic technological improvements in diesel after treatment systems, particularly in reducing Particulate Matter (PM) emissions. Those improvements generally regard the use of Diesel Oxidation Catalyst (DOC), Diesel Particulate Filter (DPF) and lately also the use of Selective Catalyst Reduction (SCR) systems along with improved engine control strategies for reduction of NOx emissions from these engines. Studies that have led to these technological advancements were made in controlled laboratory environment and are not representative of real world emissions from these engines or vehicles. In addition, formation and evolution of PM from these engines are extremely sensitive to overall changes in the dilution process.
Technical Paper

Design of a Portable Micro-Dilution Tunnel Particulate Matter Emissions Measurement System

2005-10-24
2005-01-3795
The Federal Test Procedure (FTP) for heavy-duty engines requires the use of a full-flow tunnel based constant volume sampler (CVS). These are costly to build and maintain, and require a large workspace. A small portable micro-dilution system that could be used on-board, for measuring emissions of in-use, heavy-duty vehicles would be an inexpensive alternative. This paper presents the rationale behind the design of such a portable particulate matter measuring system. The presented micro-dilution tunnel operates on the same principle as a full-flow tunnel, however given the reduced size dilution ratios can be more easily controlled with the micro dilution system. The design targets dilution ratios of at least four to one, in accordance with the ISO 8178 requirements. The unique features of the micro-dilution system are the use of only a single pump and a porous sintered stainless steel tube for mixing dilution air and raw exhaust sample.
Technical Paper

Evaluation of a Portable Micro-Dilution Tunnel Particulate Measurement System

2005-10-24
2005-01-3789
The Federal Test Procedure (FTP) for heavy-duty engines requires the use of a full-flow tunnel based constant volume sampler (CVS) which is costly to build and maintain, and requires a large workspace. A portable micro-dilution system that could be used for measuring on-board, in use emissions from heavy duty vehicles would be an inexpensive alternative compared to a full-flow CVS tunnel, as well as requiring significantly less workspace. This paper evaluates such a portable particulate matter measuring system. This micro-dilution tunnel operates on the same principle as a full-flow tunnel, however dilution ratios can be more easily controlled with the micro dilution system. The dilution ratios for the micro-dilution system were maintained at least four to one, as per ISO 8178 requirements, by measuring the mass flow rates of the dilution air and dilute exhaust.
X