Refine Your Search

Search Results

Viewing 1 to 5 of 5
Journal Article

Application of High-Speed PIV Diagnostics for Simultaneous Investigation of Flow Field and Spark Ignited Flame inside an Optical SI Engine

2017-03-28
2017-01-0656
High speed, time resolved Particle Image Velocimetry (PIV) diagnostics was applied to an optical SI engine to study the interactions between in-cylinder flow field and flame development. Optimisation and certain adaptations have been made to the diagnostic setup to enable time-resolved, simultaneous measurements of both PIV data and flame tomography imaging from the same original captured image set. In this particular study, interactions between flow and flame during lean-burn operating conditions at various tumble strength have been investigated and compared to a standard stoichiometric operation. Diagnostics were performed for both the vertical plane (x-y) and the horizontal plane (r-⊖) of the combustion chamber with a particular focus in the pent-roof area. Some major differences in the tumble flow-field prior to ignition has been observed between the lean and stoichiometric conditions.
Technical Paper

Ignition of Propane-Air Mixtures by Miniaturized Resonating Microwave Flat-Panel Plasma Igniter

2017-09-04
2017-24-0150
Recent trend in gasoline-powered automobiles focuses heavily on reducing the CO2 emissions and improving fuel efficiency. Part of the solutions involve changes in combustion chamber geometry to allow for higher turbulence, higher compression ratio which can greatly improve efficiencies. However, the changes are limited by the ignition-source and its location constraint, especially in the case of direct injection SI engines where mixture stratification is important. A new compact microwave plasma igniter based on the principle of microwave resonance was developed and tested for propane combustion inside a constant volume chamber. The igniter was constructed from a thin ceramic panel with metal inlay tuned to the corresponding resonance frequency. Microwaves generated by semiconductor based oscillator were utilized for initiation of discharge. The small and flat form factor of the flat panel igniter allows it to be installed at any locations on the surface of the combustion chamber.
Technical Paper

Effects of Microwave Enhanced Plasma on Diesel Spray Combustion

2017-03-28
2017-01-0707
The effect of microwave enhanced plasma (MW Plasma) on diesel spray combustion was investigated inside a constant volume high pressure chamber. A microwave-enhanced plasma system, in which plasma discharge generated by a spark plug was amplified using microwave pulses, was used as plasma source. This plasma was introduced to the soot cloud after the occurrence of autoignition, downstream of the flame lift-off position to allow additional plasma-generated oxidizers to be entrained into the hot combustion products. Planar laser induced incandescence (PLII) diagnostics were performed with laser sheet formed from 532 nm Nd:YAG laser to estimate possible soot reduction effect of MW plasma. A semi-quantitative comparison was made between without-plasma conventional diesel combustion and with-plasma combustion; with LII performed at different jet cross-sections in the combustion chamber.
Technical Paper

Development of Innovative Microwave Plasma Ignition System with Compact Microwave Discharge Igniter

2015-09-06
2015-24-2434
Extending the lean limit or/and exhaust-gas-recirculation (EGR) limit/s are necessary for improving fuel economy in spark ignition engines. One of the major problems preventing the engine to operate at lean conditions is stable and successful initial ignition kernel formation. A repeatable, stabilized ignition and early flame development are quite important for the subsequent part of the combustion cycle to run smooth without partial burn or cycle misfire. This study aims to develop an innovative plasma ignition system for reciprocating combustion engines with an aim to extend lean limit and for high pressure applications. This ignition system utilizes microwaves to generate plasma as an ignition source. This microwave plasma igniter is much simplified device compared to conventional spark plug. The microwave plasma ignition system consists of microwave oscillator, co-axial cable and microwave discharge igniter (MDI).
Technical Paper

Local A/F Measurement by Chemiluminescence OH*, CH* and C2* in SI Engine

2001-03-05
2001-01-0919
The chemiluminescence emission intensity can be measured with high temporal resolution, leading to understanding the chemical reaction. Time-series chemiluminescence measurements of OH*, CH* and C2* were carried out to understand flame propagation speed, its thickness and A/F ratio of combustion status. The optical piston head (quartz) allows us to visualize combustion chamber. It is found that the chemiluminescence intensity ratio of CH*/OH* and C2*/OH* can estimate local A/F. The A/F measured by O2 sensor was used for evaluation and the results indicate this method can be applicable to estimate A/F.