Refine Your Search

Search Results

Viewing 1 to 5 of 5
Journal Article

Analysis of High Mileage Gasoline Exhaust Particle Filters

2016-04-05
2016-01-0941
The purpose of this work was to examine gasoline particle filters (GPFs) at high mileages. Soot levels for gasoline direct injection (GDI) engines are much lower than diesel engines; however, noncombustible material (ash) can cause increased backpressure, reduced power, and lower fuel economy. In this study, a post mortem was completed of two GPFs, one at 130,000 mi and the other at 150,000 mi, from two production 3.5L turbocharged GDI vehicles. The GPFs were ceramic wall-flow filters containing three-way catalytic washcoat and located downstream of conventional three-way catalysts. The oil consumption was measured to be approaching 23,000 mpqt for one vehicle and 30,000 mpqt for the other. The ash contained Ca, P, Zn, S, Fe, and catalytic washcoat. Approximately 50 wt% of the collected ash was non-lubricant derived. The filter capture efficiency of lubricant-derived ash was about 50% and the non-lubricant metal (mostly Fe) deposition rate was 0.9 to 1.2 g per 10,000 mi.
Technical Paper

Calibration of a LNT-SCR Diesel Aftertreatment System

2007-04-16
2007-01-1244
An investigation into the post-LNT NH3 generation and NOx slip over an LNT was completed for the purposes of determining the proper calibration for NOx reduction over a downstream SCR. Experiments were conducted in an engine dynamometer on the DW12 2.2L diesel engine that was calibrated for rich operation. The catalyst system was evaluated at 325°C for three different engine speed/load points. Engine speeds of 1750, 2000, and 2500 rpm were chosen, resulting in a LNT space velocities of 35,000 - 68,000 hr-1. Increased lean times were tested, which resulted in NOx loadings on the LNT that ranged from 0.10 - 0.50 grams NOx/L catalyst. In addition, varied degrees of richness were tested, corresponding to lambda sensor readings of 0.90, 0.92, and 0.94. LNT performance was evaluated based on it's ability to provide a stoichiometric ratio of reactants to the SCR for NOx conversion. Gross and net NOx conversion was evaluated for a LNT-SCR system.
Technical Paper

Verification of Accelerated PM Loading for DPF Qualification Studies

2009-04-20
2009-01-1089
High gas prices combined with demand for improved fuel economy have prompted increased interest in diesel engine applications for both light-duty and heavy-duty vehicles. The development of aftertreatment systems for these vehicles requires significant investments of capital and time. A reliable and robust qualification testing procedure will allow for more rapid development with lower associated costs. Qualification testing for DPFs has its basis in methods similar to DOCs but also incorporates a PM loading method and regeneration testing of loaded samples. This paper examines the effects of accelerated loading using a PM generator and compares PM generator loaded DPFs to engine dynamometer loaded samples. DPFs were evaluated based on pressure drop and regeneration performance for samples loaded slowly and for samples loaded under accelerated conditions. A regeneration reactor was designed and built to help evaluate the DPFs loaded using the PM generator and an engine dynamometer.
Technical Paper

Impact of Fuel Metal Impurities on the Durability of a Light-Duty Diesel Aftertreatment System

2013-04-08
2013-01-0513
Alkali and alkaline earth metal impurities found in diesel fuels are potential poisons for diesel exhaust catalysts. Using an accelerated aging procedure, a set of production exhaust systems from a 2011 Ford F250 equipped with a 6.7L diesel engine have been aged to an equivalent of 150,000 miles of thermal aging and metal exposure. These exhaust systems included a diesel oxidation catalyst (DOC), selective catalytic reduction (SCR) catalyst, and diesel particulate filter (DPF). Four separate exhaust systems were aged, each with a different fuel: ULSD containing no measureable metals, B20 containing sodium, B20 containing potassium and B20 containing calcium. Metals levels were selected to simulate the maximum allowable levels in B100 according to the ASTM D6751 standard. Analysis of the aged catalysts included Federal Test Procedure emissions testing with the systems installed on a Ford F250 pickup, bench flow reactor testing of catalyst cores, and electron probe microanalysis (EPMA).
Technical Paper

Lean NOx Trap Desulfation Through Rapid Air Fuel Modulation

2000-03-06
2000-01-1200
A novel method of desulfating lean NOx traps has been developed. Rapid, large amplitude modulation of the air to fuel ratio creates an exotherm of approximately 300°C in the LNT. AFR modulation results in oxidant and reductant breakthough in a three-way catalyst mounted upstream of the LNT. During lean modulation, oxygen is stored in the LNT. During rich modulation, the reductant reacts catalytically with the stored oxygen in the LNT, generating a substantial exotherm. Rich and lean AFR events are selected commensurate with the number of cylinders in the engine, resulting in each cylinder having exactly the same AFR history. This permits a deterministic programming of spark advance and precise coordination of spark advance with the transient fueling effect. The spark advance is retarded for the rich events and increases stepwise for groups of lean events. This strategy results in minimal disturbances in the engine imep.
X