Refine Your Search

Search Results

Viewing 1 to 5 of 5
Journal Article

Wind Noise Measurements for Automotive Mirrors

2009-04-20
2009-01-0184
In order to understand the flow and wind noise characteristics generated by the outside rearview (OSRV) mirror, a series of wind noise measurements for two production mirrors was conducted at the GM Aerodynamics Lab (GMAL) wind tunnel. These measurements included the time-averaged static pressures, surface noise sources, and far field propagation noise. The data obtained in this investigation will be used for future CFD numerical validations. The two mirrors chosen for the test are the GMT360 (a truck mirror) and the GMX320 (a sedan mirror). The test mirror was mounted on an elevated table which was specially designed for the current project to avoid any significant flow boundary layer buildup on the wind tunnel floor. The test conditions reported in this paper include four inlet speeds of 30, 50, 70 and 90 mph at 0 yaw angle. To record the wind noise sources, nine surface flush-mount microphones were used.
Journal Article

Energy Efficient HVAC System with Spot Cooling in an Automobile - Design and CFD Analysis

2012-04-16
2012-01-0641
Spot, or distributed, cooling and heating is an energy efficient way of delivering comfort to an occupant in the car. This paper describes an approach to distributed cooling in the vehicle. A two passenger CFD model of an SUV cabin was developed to obtain the solar and convective thermal loads on the vehicle, characterize the interior thermal environment and accurately evaluate the fluid-thermal environment around the occupants. The present paper focuses on the design and CFD analysis of the energy efficient HVAC system with spot cooling. The CFD model was validated with wind tunnel data for its overall accuracy. A baseline system with conventional HVAC air was first analyzed at mid and high ambient conditions. The airflow and cooling delivered to the driver and the passenger was calculated. Subsequently, spot cooling was analyzed in conjunction with a much lower conventional HVAC airflow.
Technical Paper

The Immersed Boundary CFD Approach for Complex Aerodynamics Flow Predictions

2007-04-16
2007-01-0109
Standard CFD methods require a mesh that fits the boundaries of the computational domain. For a complex geometry the generation of such a grid is time-consuming and often requires modifications to the model geometry. This paper evaluates the Immersed Boundary (IB) approach which does not require a boundary-conforming mesh and thus would speed up the process of the grid generation. In the IB approach the CAD surfaces (in Stereo Lithography -STL- format) are used directly and this eliminates the surface meshing phase and also mitigates the process of the CAD cleanup. A volume mesh, consisting of regular, locally refined, hexahedrals is generated in the computational domain, including inside the body. The cells are then classified as fluid, solid and interface cells using a simple ray-tracing scheme. Interface cells, correspond to regions that are partially fluid and are intersected by the boundary surfaces.
Technical Paper

Exterior Water Management Using a Custom Euler-Lagrange Simulation Approach

2007-04-16
2007-01-0101
The reduction of hardware vehicle models during development drives the necessity to transfer most hardware tests to VR Simulation. Exterior water management is one of the topics, where complex physics meet everyday situations. A vehicle contamination test conducted in a wind tunnel is selected to be transferred to numerical simulation. The method of choice is the Euler-Lagrange approach with modeled ‘liquid’ wall particles. A new wall film model has been developed in the present study to include the observed liquid properties in physical test. This model takes the local wetting conditions into account and constitutes a reformulation of the local force balance of the wall liquid. Also the wall film separation model has been refined and improved. With this new approach, the gas/liquid, liquid/solid and liquid/liquid interaction has been remodeled.
Technical Paper

Thermal Comfort Prediction and Validation in a Realistic Vehicle Thermal Environment

2012-04-16
2012-01-0645
The focus of this study is to validate the predictive capability of a recently developed physiology based thermal comfort modeling tool in a realistic thermal environment of a vehicle passenger compartment. Human subject test data for thermal sensation and comfort was obtained in a climatic wind tunnel for a cross-over vehicle in a relatively warm thermal environment including solar load. A CFD/thermal model that simulates the vehicle operating conditions in the tunnel, is used to provide the necessary inputs required by the stand-alone thermal comfort tool. Comparison of the local and the overall thermal sensation and comfort levels between the human subject test and the tool's predictions shows a reasonably good agreement. The next step is to use this modeling technique in designing and developing energy-efficient HVAC systems without compromising thermal comfort of the vehicle occupants.