Refine Your Search

Search Results

Viewing 1 to 9 of 9
Journal Article

Removal of EGR Cooler Deposit Material by Flow-Induced Shear

2013-04-08
2013-01-1292
A number of studies have identified a tendency for exhaust gas recirculation (EGR) coolers to foul to a steady-state level and subsequently not degrade further. One possible explanation for this behavior is that the shear force imposed by the gas velocity increases as the deposit thickens. If the shear force reaches a critical level, it achieves a removal of the deposit material that can balance the rate of deposition of new material, creating a stabilized condition. This study reports efforts to observe removal of deposit material in-situ during fouling studies as well as an ex-situ removal through the use of controlled air flows. The critical gas velocity and shear stress necessary to cause removal of deposit material is identified and reported. In-situ observations failed to show convincing evidence of a removal of deposit material. The results show that removal of deposit material requires a relatively high velocity of 40 m/s or higher to cause removal.
Technical Paper

Direct Measurement of EGR Cooler Deposit Thermal Properties for Improved Understanding of Cooler Fouling

2009-04-20
2009-01-1461
Exhaust gas recirculation (EGR) cooler fouling has become a significant issue for compliance with NOx emissions standards. This paper reports results of a study of fundamental aspects of EGR cooler fouling. An apparatus and procedure were developed to allow surrogate EGR cooler tubes to be exposed to diesel engine exhaust under controlled conditions. The resulting fouled tubes were removed and analyzed. Volatile and non-volatile deposit mass was measured for each tube. Thermal diffusivity of the deposited soot cake was measured by milling a window into the tube and using the Xenon flash lamp method. The heat capacity of the deposit was measured at temperatures up to 430°C and was slightly higher than graphite, presumably due to the presence of hydrocarbons. These measurements were combined to allow calculation of the deposit thermal conductivity, which was determined to be 0.041 W/mK, only ∼1.5 times that of air and much lower than the 304 stainless steel tube (14.7 W/mK).
Technical Paper

Emission Performance of Low Cetane Naphtha as Drop-In Fuel on a Multi-Cylinder Heavy-Duty Diesel Engine and Aftertreatment System

2017-03-28
2017-01-1000
Greenhouse gas regulations and global economic growth are expected to drive a future demand shift towards diesel fuel in the transportation sector. This may create a market opportunity for cost-effective fuels in the light distillate range if they can be burned as efficiently and cleanly as diesel fuel. In this study, the emission performance of a low cetane number, low research octane number naphtha (CN 34, RON 56) was examined on a production 6-cylinder heavy-duty on-highway truck engine and aftertreatment system. Using only production hardware, both the engine-out and tailpipe emissions were examined during the heavy-duty emission testing cycles using naphtha and ultra-low-sulfur diesel (ULSD) fuels. Without any modifications to the hardware and software, the tailpipe emissions were comparable when using either naphtha or ULSD on the heavy duty test cycles.
Technical Paper

Impact of Fuel Metal Impurities on the Durability of a Light-Duty Diesel Aftertreatment System

2013-04-08
2013-01-0513
Alkali and alkaline earth metal impurities found in diesel fuels are potential poisons for diesel exhaust catalysts. Using an accelerated aging procedure, a set of production exhaust systems from a 2011 Ford F250 equipped with a 6.7L diesel engine have been aged to an equivalent of 150,000 miles of thermal aging and metal exposure. These exhaust systems included a diesel oxidation catalyst (DOC), selective catalytic reduction (SCR) catalyst, and diesel particulate filter (DPF). Four separate exhaust systems were aged, each with a different fuel: ULSD containing no measureable metals, B20 containing sodium, B20 containing potassium and B20 containing calcium. Metals levels were selected to simulate the maximum allowable levels in B100 according to the ASTM D6751 standard. Analysis of the aged catalysts included Federal Test Procedure emissions testing with the systems installed on a Ford F250 pickup, bench flow reactor testing of catalyst cores, and electron probe microanalysis (EPMA).
Technical Paper

Influence of Soot Surface Changes on DPF Regeneration

2004-10-25
2004-01-3043
Soot oxidation has been a critical issue for regeneration of diesel particulate filters (DPFs). The design of the regeneration strategy and the durability requirement for DPFs depend on an understanding of soot burning. Raman and thermal analysis have been used to monitor surface configuration changes. Under thermal aging, engine soot undergoes a transformation from a mostly amorphous carbon structure into more orderly polyaromatic structures which exhibit resistance towards oxidation. Certain neutralization products, such as thio-phosphorous and phosphorous derivatives, can also alter the thermal behavior of soot through interactions between ash and soot adsorbed species. The incomplete regeneration can be attributed to a buildup of a physical barrier that prevents oxygen or NO2 from diffusing effectively onto the carbon surface.
Technical Paper

Effectiveness Stabilization and Plugging in EGR Cooler Fouling

2014-04-01
2014-01-0640
Fouling in EGR coolers occurs because of the presence of soot and condensable species (such as hydrocarbons) in the gas stream. Fouling leads to one of two possible outcomes: stabilization of effectiveness and plugging of the gas passages within the cooler. Deposit formation in the cooler under high-temperature conditions results in a fractal deposit that has a characteristic thermal conductivity of ∼0.033 W/m*K and a density of 0.0224 g/cm3. Effectiveness becomes much less sensitive to changes in thermal resistance as fouling proceeds, creating the appearance of “stabilization” even in the presence of ongoing, albeit slow, deposit growth. Plugging occurs when the deposit thermal resistance is several times lower because of the presence of large amounts of condensed species. The deposition mechanism in this case appears to be soot deposition into a liquid film, which results in increased packing efficiency and decreased void space in the deposit relative to high-temperature deposits.
Technical Paper

Analysis of Lacquer Deposits and Plugging Found in Field-Tested EGR Coolers

2014-04-01
2014-01-0629
All high-pressure exhaust gas recirculation (EGR) coolers become fouled during operation due to thermophoresis of particulate matter and condensation of hydrocarbons present in diesel exhaust. In some EGR coolers, fouling is so severe that deposits form plugs strong enough to occlude the gas passages thereby causing a complete failure of the EGR system. In order to better understand plugging and means of reducing its undesirable performance degradation, EGR coolers exhibiting plugging were requested from and provided by industry EGR engineers. Two of these coolers contained glassy, brittle, lacquer-like deposits which were analyzed using gas chromatography-mass spectrometry (GC-MS) which identified large amounts of oxygenated polycyclic aromatic hydrocarbons (PAHs). Another cooler exhibited similar species to the lacquer but at a lower concentration with more soot.
Technical Paper

Neutron Tomography of Exhaust Gas Recirculation Cooler Deposits

2014-04-01
2014-01-0628
Exhaust gas recirculation (EGR) cooler fouling has become a significant issue for compliance with NOx emissions standards. Exhaust gas laden with particulate matter flows through the EGR cooler which causes deposits to form through thermophoresis and condensation. The low thermal conductivity of the resulting deposit reduces the effectiveness of the EGR system. In order to better understand this phenomenon, industry-provided coolers were characterized using neutron tomography. Neutrons are strongly attenuated by hydrogen but only weakly by metals which allows for non-destructive imaging of the deposit through the metal heat exchanger. Multiple 2-D projections of cooler sections were acquired by rotating the sample around the axis of symmetry with the spatial resolution of each image equal to ∼70 μm. A 3-D tomographic set was then reconstructed, from which slices through the cooler sections were extracted across different planes.
Journal Article

Characterization of Field-Aged EGR Cooler Deposits

2010-10-25
2010-01-2091
Exhaust gas recirculation (EGR) cooler fouling has become a significant issue for compliance with nitrogen oxides (NOx) emissions standards. In order to better understand fouling mechanisms, eleven field-aged EGR coolers provided by seven different engine manufacturers were characterized using a suite of techniques. Microstructures were characterized using scanning electron microscopy (SEM) and optical microscopy following mounting the samples in epoxy and polishing. Optical microscopy was able to discern the location of hydrocarbons in the polished cross-sections. Chemical compositions were measured using thermal gravimetric analysis (TGA), differential thermal analysis (DTA), gas chromatography-mass spectrometry (GC-MS), x-ray photoelectron spectroscopy (XPS), energy dispersive spectroscopy (EDS) and x-ray diffraction (XRD). Mass per unit area along the length of the coolers was also measured.
X