Journal Article

Improving Cabin Thermal Comfort by Controlling Equivalent Temperature

2009-11-10
2009-01-3265
An aircraft environmental control system (ECS) is commonly designed for a cabin that has been divided into several thermal control zones; each zone has an air flow network that pulls cabin air over an isolated thermocouple. This single point measurement is used by the ECS to control the air temperature and hence the thermal environment for each zone. The thermal environment of a confined space subjected to asymmetric thermal loads can be more fully characterized, and subsequently better controlled, by determining its “equivalent temperature.” This paper describes methodology for measuring and controlling cabin equivalent temperature. The merits of controlling a cabin thermal zone based on its equivalent temperature are demonstrated by comparing thermal comfort, as predicted by a “virtual thermal manikin,” for both air-temperature and equivalent-temperature control strategies.
Technical Paper

Evaluating a Vehicle Climate Control System with a Passive Sensor Manikin coupled with a Thermal Comfort Model

2018-04-03
2018-01-0065
In a previous study, a passive sensor (HVAC) manikin coupled with a human thermal model was used to predict the thermal comfort of human test participants. The manikin was positioned among the test participants while they were collectively exposed to a mild transient heat up within a thermally asymmetric chamber. Ambient conditions were measured using the HVAC manikin’s distributed sensor system, which measures air velocity, air temperature, radiant heat flux, and relative humidity. These measurements were supplied as input to a human thermal model to predict thermophysiological response and subsequently thermal sensation and comfort. The model predictions were shown to accurately reproduce the group trends and the “time to comfort” at which a transition occurred from a state of thermal discomfort to comfort. In the current study, the effectiveness of using a coupled HVAC manikin-model system to evaluate a vehicle climate control system was investigated.
Technical Paper

Simulating Physiological Response with a Passive Sensor Manikin and an Adaptive Thermal Manikin to Predict Thermal Sensation and Comfort

2015-04-14
2015-01-0329
Reliable assessment of occupant thermal comfort can be difficult to obtain within automotive environments, especially under transient and asymmetric heating and cooling scenarios. Evaluation of HVAC system performance in terms of comfort commonly requires human subject testing, which may involve multiple repetitions, as well as multiple test subjects. Instrumentation (typically comprised of an array of temperature sensors) is usually only sparsely applied across the human body, significantly reducing the spatial resolution of available test data. Further, since comfort is highly subjective in nature, a single test protocol can yield a wide variation in results which can only be overcome by increasing the number of test replications and subjects. In light of these difficulties, various types of manikins are finding use in automotive testing scenarios.
Technical Paper

Evaluating a Heavy-Duty Truck Climate Control System Using Thermal Comfort-Focused Testing and Simulation Techniques

2019-04-02
2019-01-0696
A test protocol previously developed for automotive applications was adapted to evaluate the performance of a climate control system for a heavy-duty truck. Human subjects, as well as a test system composed of a high-resolution passive sensor manikin and a human thermal model, were employed to evaluate thermal comfort perception. Testing was performed in a climate-controlled wind tunnel equipped with a dynamometer. The truck’s HVAC system performance was evaluated in a −10 °C environment. Additionally, the test protocol was designed to explore a large range of thermal sensation and comfort states. Subjective responses, including thermal sensation and comfort, as well as thermo-physiological state information, quantified by skin temperatures measured across the body, were obtained from the human test participants and compared to that which was indicated by the test system.
Journal Article

Coupling a Passive Sensor Manikin with a Human Thermal Comfort Model to Predict Human Perception in Transient and Asymmetric Environments

2017-03-28
2017-01-0178
Passive sensor (HVAC) manikins have been developed to obtain high-resolution measurements of environmental conditions across a representative human body form. These manikins incorporate numerous sensors that measure air velocity, air temperature, radiant heat flux, and relative humidity. The effect of a vehicle’s climate control system on occupant comfort can be characterized from the data collected by an HVAC manikin. Equivalent homogeneous temperature (EHT) is often used as a first step in a cabin comfort analysis, particularly since it reduces a large data set to a single intuitive number. However, the applicability of the EHT for thermal comfort assessment is limited since it does not account for human homeostasis, i.e., that the human body actively counter-balances heat flow with the environment to maintain a constant core temperature. For this reason, a thermo-physiological human model is required to accurately simulate the body’s dynamic response to a changing environment.