Refine Your Search

Search Results

Journal Article

Measurement of Equivalence Ratio in a Light-Duty Low Temperature Combustion Diesel Engine by Planar Laser Induced Fluorescence of a Fuel Tracer

2011-09-11
2011-24-0064
The spatial distribution of the mixture equivalence ratio within the squish volume is quantified under non-combusting conditions by planar laser-induced fluorescence (PLIF) of a fuel tracer (toluene). The measurements were made in a single-cylinder, direct-injection, light-duty diesel engine at conditions matched to an early-injection low temperature combustion mode. A fuel amount corresponding to a low load (3.0 bar indicated mean effective pressure) operating condition was introduced with a single injection. Data were acquired during the mixture preparation period from near the start of injection (-22.5° aTDC) until the crank angle where the start of high-temperature heat release normally occurs (-5° aTDC). Despite the opposing squish flow, the fuel jets penetrate through the squish region to the cylinder bore. Although rapid mixing is observed in the head of each jet, rich regions remain at the head at the start of high-temperature heat release.
X