Refine Your Search

Search Results

Technical Paper

New Asymmetric Plugging Layout of Diesel Particulate Filters for the Pressure Drop Reduction

2014-04-01
2014-01-1512
Diesel particulate filters (DPFs) equipped with diesel vehicles have become indispensable components to capture the soot emitted from the engines from a viewpoint of both human health and global warming problems as well as the prevailing regulations. Meanwhile, the pressure drop caused by them leads to a direct increase of fuel consumption. In order to reduce it guaranteeing the sufficient soot filtration efficiency, we have developed the new concept of asymmetric plugging layout for the DPF design, so-called Valuable Plugging Layout (VPL), on the basis of octosquare (OS) structure and have clarified the advantage of the pressure drop reduction both experimentally and theoretically. The VPL-DPF consists of two kinds of octagonal/square inlet channels and octagonal outlet channels, and there are thought to be five filtration velocity modes as well as four kinds of soot deposit layers on each side of the inlet channel walls.