Refine Your Search

Search Results

Viewing 1 to 5 of 5
Journal Article

The Effect of Cooled Exhaust Gas Recirculation for a Naturally Aspirated Stationary Gas Engine

2016-11-08
2016-32-0093
Small natural gas cogeneration engines frequently operate with lean mixture and late ignition timing to comply with NOx emission standards. Late combustion phasing is the consequence, leading to significant losses in engine efficiency. When substituting a part of the excess air with exhaust gas, heat capacity increases, thus reducing NOx emissions. Combustion phasing can be advanced, resulting in a thermodynamically more favourable heat release without increasing NOx but improving engine efficiency. In this work, the effect of replacing a part of excess air with exhaust gas was investigated first in a constant volume combustion chamber. It enabled to analyse the influence of the exhaust gas under motionless initial conditions for several relative air-fuel ratios (λ = 1.3 to 1.7). Starting from the initial value of λ, the amount of CH4 was maintained constant as a part of the excess air was replaced by exhaust gas.
Technical Paper

Controlled Hot Surface Ignition in Stationary Petrol and Natural Gas Operation

2012-10-23
2012-32-0006
An operation with a lean air-fuel mixture enables smaller cogeneration gas engines to operate at both high efficiency and low NOx emissions. Conventionally, the combustion process is induced through spark ignition. However, its small reactive mixture volume sets limits on increasing the air-fuel ratio, as a higher dilution reduces mixture inflammability as well as flame propagation speed. In addition, the spark plug durability is limited due to electrode wear, particularly through spark erosion, causing high maintenance costs. The ignition by means of a hot surface has great potential to extend the frequency of servicing intervals as well as to improve the trade-off between engine efficiency and NOx emissions. Compared to conventional spark ignition, ignition by means of a hot surface is achieved by accelerated combustion. The latter is produced by an increased initial reactive mixture volume.
Journal Article

High Efficiency by Miller Valve Timing and Stoichiometric Combustion for a Naturally Aspirated Single Cylinder Gas Engine

2020-01-24
2019-32-0588
Small-scale cogeneration units (Pel < 50 kW) frequently use lean mixture and late ignition timing to comply with current NOx emission limits. Future tightened NOx limits might still be met by means of increased dilution, though both indicated and brake efficiency drop due to further retarded combustion phasing and reduced brake power. As an alternative, when changing the combustion process from lean burn to stoichiometric, a three-way-catalyst allows for a significant reduction of NOx emissions. Combustion timing can be advanced, resulting in enhanced heat release and thus increased engine efficiency. Based on this approach, this work presents the development of a stoichiometric combustion process for a small naturally aspirated single cylinder gas engine (Pel = 5.5 kW) originally operated with lean mixture. To ensure low NOx emissions, a three-way-catalyst is used.
Technical Paper

Miller/Atkinson Valve Timing as Full Load Concept for a Naturally Aspirated Cogeneration Engine

2015-11-17
2015-32-0713
Lean burn operation allows small cogeneration engines to achieve both high efficiency and low NOx emissions. While further mixture dilution enables future emission standards to be met, it leads to retarded combustion phasing and losses in indicated engine efficiency. In the case of naturally aspirated engines, IMEP drops due to lower fuel fraction, increasing brake specific fuel consumption. In this work, an alternative engine configuration was investigated that improves the trade-off between engine efficiency, NOx emissions and IMEP. It combines well-established means such as Miller/Atkinson valve timing and optimised intake system for a single-cylinder cogeneration engine, operating with homogenous lean air-natural gas mixture. First, the engine configuration was analysed using a detailed 1D CFD model, implying a significant potential in reaching the project target.
Technical Paper

Effects of Intake Pressure and Air-Fuel Ratio on Controlled Hot Surface Ignition Operating with Natural Gas

2015-11-17
2015-32-0721
In an effort to reduce both maintenance costs and NOx emissions of small cogeneration engines operated with natural gas, an alternative ignition system that allows stable operation at very lean homogeneous air-fuel mixtures has been developed. Combustion is induced by an electrically heated ceramic glow plug, whose temperature is controlled by an ECU. Adjusting hot surface temperature allows shifting the inflammation timing of the mixture and, therefore, the phasing of combustion in the engine cycle. The main aim of this work was to determine the effect of intake pressure and air-fuel ratio on the parameters of hot surface ignition (HSI) and understand which are the factors limiting stable HSI operation in terms of cycle-by-cycle variations.