High Frame Rate Flow Visualization and LDV Measurements in a Steady Flow Cylinder Head Assembly

1991-02-01
910473
The purpose of this work was to develop a high speed flow visualization system which could be used to observe the behavior of the air flow in a steady flow cylinder head assembly. This type of experimental rig has been used by engineers for many years to evaluate valve discharge coefficients. This study is believed to be the first high speed flow visualization of the air flow in a system of this type. Particular emphasis was placed on the characterization of intake generated swirl and tumble motions within the cylinder. A 40 watt copper vapor laser was used to expose motion picture films at 5000 frames per second. The light scattering medium was phenolic microballoons. Based on the flow visualization results, selected LDV measurements were made to quantify the visual observations. A propylene glycol aerosol was used for seeding in the LDV experiments.