Refine Your Search

Search Results

Viewing 1 to 5 of 5
Standard

Design and Performance Specifications for a Generic Buck Representing a Small Family Car Used in the Assessment of Pedestrian Dummy Whole Body Impact Response

2019-01-08
CURRENT
J3093_201901
This Information Report addresses the design and performance specifications for a generic buck to be used in full-scale vehicle to pedestrian tests conducted to evaluate pedestrian dummy performance. Specifically, the buck is designed to mimic the impact response of the front end of a sedan within the small family car class during a collision with a pedestrian. The goal is to develop a generic buck with simplified geometry and a limited number of components made of clearly defined and readily available engineering materials to facilitate fabrication and reproducibility. To ensure performance of the buck, it is specified that the buck mimics the maximum crush distance, absorbed energy, and maximum force corresponding to a sedan within the small family car class during a pedestrian impact.
Standard

Performance Specifications for a Midsize Male Pedestrian Research Dummy

2010-10-14
HISTORICAL
J2782_201010
While it is recognized that collisions involve pedestrians of all sizes, this Information Report addresses performance specifications for a midsize adult male research dummy. This approach stems from the greater knowledge of biomechanics and existing dummy technologies for the midsize male relative to other adult sizes and children. While not the initial objective, it is envisioned that additional performance specifications for other sizes of pedestrian research dummies will be developed in the future based on accepted scaling procedures. The specific requirements for the pedestrian dummy have been based on a collective assessment of pedestrian injury, response, and anthropometry priorities from the experimental, epidemiologic, and computational literature. In general, the objective was to specify performance specifications based on human characteristics and the impact response of post-mortem human subjects rather than to specify the design of a particular physical device.
Standard

Performance Specifications for a Midsize Male Pedestrian Research Dummy

2019-11-26
CURRENT
J2782_201911
While it is recognized that collisions involve pedestrians of all sizes, this Information Report addresses performance specifications for a midsize adult male research dummy. This approach stems from the greater knowledge of biomechanics and existing dummy technologies for the midsize male relative to other adult sizes and children. While not the initial objective, it is envisioned that additional performance specifications for other sizes of pedestrian research dummies will be developed in the future based on accepted scaling procedures. The specific requirements for the pedestrian dummy have been based on a collective assessment of pedestrian injury, response, and anthropometry priorities from the experimental, epidemiologic, and computational literature. In general, the objective was to specify performance specifications based on human characteristics and the impact response of post-mortem human subjects rather than to specify the design of a particular physical device.
Standard

Pedestrian Dummy Full Scale Test Results and Resource Materials

2010-10-14
HISTORICAL
J2868_201010
The materials included in this J document are not intended to represent a complete summary of pedestrian safety research activities, but are rather a collection of materials which can be helpful to users of SAE J2782.
Standard

Human Tolerance to Impact Conditions as Related to Motor Vehicle Design

2011-02-21
CURRENT
J885_201102
This report reviews current1 quantitative data on human tolerance levels without recommending specific limits. Data developed on humans (including cadavers) are presented where available; however, in many cases animal data are provided where no suitable human results have been reported. This report confines itself, as much as possible, to information of direct use to the automotive designer and tester. Data of only academic interest are largely omitted; therefore, J885 should not be considered as a complete summary of all available biomechanical data. Most of the data cited in this report applies to adult males since little information is available on women or children. The summary data provided in the tables should be considered in conjunction with the accompanying descriptive test. This material explains the manner in which the data were obtained and provides an insight as to their limitations.