Technical Paper

Simulation of Freezing and Frozen Precipitation for the Evaluation of De/anti-icing Systems

2007-09-24
2007-01-3318
Simulating freezing and frozen precipitation in an indoor laboratory setting can permit year round evaluation of de/anti-icing systems and fluids. At AMIL, freezing rain, freezing drizzle, icing fog and in-cloud icing as well as frost, snow, ice pellets and icing clouds can be simulated in a variety of cold chambers of different heights and with different wind conditions using specialized spraying systems and temperature set-ups. Freezing rain is simulated using a 9 m high vertical chamber capable of supercooling water droplets from 100 to 1000 μm, so they freeze not long after impact. The freezing drizzle is simulated in a 4 m high chamber where supercooled droplets from 50 to 250 μm freeze on impact. Icing fog and in-cloud icing are simulated with the help of a pneumatic spray nozzle system which allows for a finer water spray, in the 20 μm diameter range. The frost is simulated by saturating a cold room with humidity generated from a heated, temperature controlled water bath.