Refine Your Search

Search Results

Viewing 1 to 2 of 2
Technical Paper

Real-Time and Direct Measurement of Pollutants in Exhaust Gas Utilizing Supersonic Jet / Resonance Enhanced Multi-Photon Ionization

2008-04-14
2008-01-0761
Supersonic jet / resonance enhanced multi-photon ionization (Jet-REMPI) technique was focused on the analyzing method for gas mixture like exhaust gas from automobiles. In this method, when the mass number and wavelength of excitation laser are determined adequately, the target compound can be monitored selectively. We developed a new analyzer utilizing REMPI method. Using this analyzer, real-time monitoring of exhaust gas from a motorcycle and diesel vehicles was conducted. As a result of real-time monitoring test of the vehicles, concentrations of aromatic compounds like benzene toluene etc. were quantified and real-time changes of their concentrations were observed.
Technical Paper

Real-time Analysis of Benzene in Exhaust Gas from Driving Automobiles Using Jet-REMPI Method

2009-11-02
2009-01-2740
Real-time analysis of benzene in automobile exhaust gas was performed using the Jet-REMPI (supersonic jet / resonance enhanced multi-photon ionization) method. Real-time benzene concentration of two diesel trucks and one gasoline vehicle driving in Japanese driving modes were observed under ppm level at 1 s intervals. As a result, it became obvious that there were many differences in their emission tendencies, because of their car types, driving conditions, and catalyst conditions. In two diesel vehicle, benzene emission tendencies were opposite. And, in a gasoline vehicle, emission pattern were different between hot and cold conditions due to the catalyst conditions.