Technical Paper

Flight Testing of the Two-Phase Flow Flight Experiment

1998-07-13
981816
The Two Phase Flow (TPF) Experiment is an integrated two-phase thermal control system designed to address capillary pumped loop component and system performance issues. The Two Phase Flow Experiment was flown aboard the Space Shuttle Discovery (STS-85) from August 7 - 19, 1997 as part of the Technology Applications and Science-01 (TAS-01) mission. The experiment was contained in a Hitchhiker canister and consisted of a capillary pumped loop (CPL), electronics, and associated instrumentation and wiring. The CPL contained four capillary evaporators (two large diameter and two small diameter), two parallel condensers, a two-phase temperature controlled reservoir, liquid and vapor tubing, individual capillary isolators, and a capillary vapor flow valve. The system working fluid was anhydrous ammonia. The system was operated for a total of 176 hours during the mission with 61 test cycles performed.
Technical Paper

Capillary Limit in a Loop Heat Pipe with a Single Evaporator

2002-07-15
2002-01-2502
This paper describes a study on the capillary limit of a loop heat pipe (LHP) at low powers. The slow thermal response of the loop at low powers makes it possible to observe interactions among various components after the capillary limit is exceeded. The capillary limit at low powers is achieved by imposing an additional pressure drop on the vapor line through the use of a metering valve. A differential pressure transducer is also used to measure the pressure drop across the evaporator and the compensation chamber (CC). Test results show that when the capillary limit is exceeded, vapor will penetrate the primary wick, resulting in an increase of the CC temperature. Because the evaporator can tolerate vapor bubbles, the LHP will continue to function and may reach a new steady state at a higher operating temperature. Thus, the LHP will exhibit a graceful degradation in performance rather than a complete failure.
Technical Paper

Thermal Vacuum Testing of the Capillary Pumped Loop Flight Experiment

1994-06-01
941599
The Capillary Pumped Loop Flight Experiment (CAPL) is a prototype of the Earth Observing System (EOS) instrument thermal control systems, which are based on two-phase heat transfer technology. The CAPL experiment has been functionally tested in a thermal vacuum chamber at NASA's Goddard Space Flight Center (GSFC). The tests performed included start-up tests, simulated EOS instrument power profiles, low and high power profiles, a variety of uneven coldplate heating tests, subcooling requirement tests, an induced deprime test, reprimes, saturation temperature changes, and a hybrid (mechanical pump-assist) test. There were a few unexpected evaporator deprimes, but overall the testing was successful. The results of all of the tests are discussed, with emphasis on the deprimes and suspected causes.
Technical Paper

Flight Testing of the Capillary Pumped Loop Flight Experiment

1995-07-01
951566
The Capillary Pumped Loop Flight Experiment (CAPL) employs a passive two-phase thermal control system that uses the latent heat of vaporization of ammonia to transfer heat over long distances. CAPL was designed as a prototype of the Earth Observing System (EOS) instrument thermal control systems. The purpose of the mission was to provide validation of the system performance in micro-gravity, prior to implementation on EOS. CAPL was flown on STS-60 in February, 1994, with some unexpected results related to gravitational effects on two-phase systems. Flight test results and post flight investigations will be addressed, along with a brief description of the experiment design.
Technical Paper

Design Evolution of the Capillary Pumped Loop (CAPL 2) Flight Experiment

1996-07-01
961431
The Capillary Pumped Loop Flight Experiment (CAPL 2) employs a passive two-phase thermal control system that uses the latent heat of vaporization of ammonia to transfer heat over long distances. CAPL was designed as a prototype of the Earth Observing System (EOS) instrument thermal control systems. The purpose of the mission was to provide validation of the system performance in microgravity, prior to implementation on EOS. CAPL 1 was flown on STS-60 in February, 1994, with some unexpected results related to gravitational effects on two-phase systems. Start-up difficulties on CAPL 1 led to a redesign of the experiment (CAPL 2) and a reflight on STS-69 in September of 1995. The CAPL 2 flight was extremely successful and the new “starter pump” design is now baselined for the EOS application. This paper emphasizes the design history, the CAPL 2 design, and lessons learned from the CAPL program.
Technical Paper

Thermal Performance of Capillary Pumped Loops Onboard Terra Spacecraft

2004-07-19
2004-01-2504
The Terra spacecraft is the flagship of NASA’s Earth Science Enterprise. It provides global data on the atmosphere, land, and oceans, as well as their interactions with solar radiation and one another. Three Terra instruments utilize Capillary Pumped Heat Transport Systems (CPHTS) for temperature control. Each CPHTS, consisting of two capillary pumped loops (CPLs) and several heat pipes and electrical heaters, is designed for instrument heat loads ranging from 25W to 264W. The working fluid is ammonia. Since the launch of the Terra spacecraft in December 1999, each CPHTS has been providing a stable interface temperature specified by the instrument under all modes of spacecraft and instrument operations. The ability to change the CPHTS operating temperature upon demand while in service has also extended the useful life of one instrument. This paper describes the design and on-orbit performance of the CPHTS thermal systems.