Technical Paper

Engine Intake Throttling for Active Regeneration of Diesel Particle Filters

2003-03-03
2003-01-0381
By means of catalysts, either coatings or fuel-borne, the temperature level for triggering the combustion of soot stored in particulate traps can be lowered from 600°C to 300°C, in case of CRT even to 250°C; but even that may fail, if in dense traffic application of a city-bus only 150 - 200°C are attained - similar situations of low load duty cycles exist in most other applications too. Mere passive regeneration may then not be sufficient, active support is needed. This paper presents an “active” method applicable to any Diesel engine to increase the exhaust temperature whenever required: load of Diesel engines is controlled by the fuel flow only; consequently, excess of air above stochiometric requirement is increasing from λ = 1.5 to λ = 8 with decreasing load, which is in fact the principal cause of the low temperature at light loads.